connector strip 15amp

Max 4 Strip Connectors, 15A, Plastic Medium Duty, 12 Terminal Available Bk Or Tr

Catalogue Number: BP543
connector strip 15amp
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Blue Point
Cable cross section
6-6 mm² fine stranded without cable end sleeve
[In] rated current
15 A
Connector type
  • 1 screw terminals
  • 2 screw terminals
    • Number of poles
      12
      Mounting support
      panel
      Material
      flameproof high-impact polystyrene: insulation
      Width
      23 mm grid pattern:
      Minimum mounting height
      19 mm
      Length
      133 mm
      Ambient air temperature for operation
      100 °C
      Standards
      CS/840/N
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information

      Frequently Asked Questions

      hide show

      What IP rating is the XMPA12B2131?

      The IP rating is IP54.

      What is the replacement for Sarel 87903 ?

      The replacement for Sarel 87903 is NSYCVF300M230PF

      NSYCVF300M230PF 
      ClimaSys forced vent. IP54, 300m3/h, 230V, with outlet grille and filter G2

       

      What is the IP rating of the VW3A1006 keypad?

      Issue:
      What is the IP rating of the VW3A1006 keypad?

      Product Line:
      ALTIVAR 12, ALTIVAR 312

      Environment:
      All

      Cause:
      What is the IP rating of the VW3A1006 keypad?

      Resolution:
      This keypad is rated for IP54.

      Where is information on ATV31C drive ratings?


      Issue:
      Where is information on ATV31C drive ratings?

      Product Line:
      ATV31C

      Environment:
      All serial numbers for ATV31C

      Cause:
      N/A

      Resolution:
      The Installation manual, document 1624729, is attached.                
       

      What are the characteristics of a BP535?

      Catalogue Number BP535
      Current Rating 30A
      Max Temperature Rating 100°C
      Length 175mm
      Width 28mm
      Height 21mm
      Tunnel Diameter 4mm
      Maximum Cable Accommodated 16mm²
      Heat Resisting Material F/R Polyethylene
      Certificate of suitability CS/840/N

      What is the lug torque requirement for the 8910DPA43?

      Issue:
      8910DP/DPA wire torque

      Product Line:
      Class 8910 Type DP and Type DPA, Definite Purpose Contactors

      Environment:
      Series C, Types DP and DPA

      Resolution:
      Power Terminals
      Class 8910 DP = #10-32 screws - 22 inch lb.  Box lugs - 40 inch lb
      Class 8910DPA (20A to 40A) =  #10-32 screws - 22 inch lb.  Box lugs - 40 inch lb

      What is the maximum number of contact blocks that can be mounted to a 9001SK Push Button?

      Issue:
      How many contact blocks can be mounted to a maintained 9001SK Push Button?

      Product Line:
      Operator Interface Push buttons 30mm

      Environment:
      1,3R, 4, 4X, 12
      IP54, 55, 65

      Cause:
      Installation and Configuration

      Resolution:
      Maximum is 4 contacts blocks (4) 9001KA1

      Can I replace a ATV61WU55N4U with an standard ATV61HU55N4U?

      Issue:
      Can I replace a ATV61WU  with an ATV61HU ? 

      Product Line:
      ATV61W

      Environment:
      All

      Cause:
      None

      Resolution:
      The ATV61W is a self contained NEMA 12 enclosed drive.  The drive inside the 61W is not a standard drive.  The drive is an ATV61H modified for this enclosure. Therefore the answer to the ATV61H replacing the ATV61W is no.  This is not an option.

      Does Schneider Electric offer a replacement for the Berger Lahr WPM-311 controller?

      The entire product line of WPM-311 type controllers from Berger Lahr are obsolete and no longer available
      Schneider Electric does not offer a drop in replacement.

      The Berger Lahr WPM311 uses a special programming environment which was unique to Berger Lahr ( Depending on the firmware, Bpro3 programming system or ProOed3 Programming system )

      The WPM311 is a 4 axis motion controller that utilizes pulse/direction type outputs which were most commonly used to interface with stepping motor drives.

      So to replace the WPM311 you will have to not only find a controller that is capable of controlling multiple axis, but you will also have to write a motion program that duplicates the current application process.

      You may try contacting the OEM machine builder, they may have spare WPM311 controllers or they may have already developed a retrofit solution.  

      Service is still available at the Schneider Electric Repair Center in Greensboro NC


      rev 2-20-18

      Does Schneider Electric offer a replacement for the Berger Lahr WPM-311 controller?

      The entire product line of WPM-311 type controllers from Berger Lahr are obsolete and no longer available
      Schneider Electric does not offer a direct replacement.

      The Berger Lahr WPM311 uses a special programming environment which was unique to Berger Lahr ( Depending on the firmware, Bpro3 programming system or ProOed3 Programming system )

      The WPM311 is a 4 axis motion controller that utilizes pulse/direction type outputs which were most commonly used to interface with stepping motor drives.

      To replace the WPM311 you will need a controller that is capable of controlling multiple axis, and you must write a motion program that duplicates the current application process.

      You may try contacting the OEM machine builder, they may have spare WPM311 controllers or they may have already developed a retrofit solution.  

      Service is still available at the Schneider Electric Repair Center in Greensboro NC.


      Rev 8-8-17

      Are NEMA 1 enclosures available for the 8910 Type DP and DPA contactors?

      Issue:
      Enclosure for 8910 contactors

      Product Line:
      Class 8910 Definite Purpose Contactors

      Environment:
      North American Products

      Cause:
      Looking for a NEMA 1 enclosure needed for definite purpose contactor

      Resolution:
      Yes, select from the table below.

      Contactor      Enclosure
      8910DP11      9991DPG1
      8910DP21      9991DPG1
      8910DP31      9991DPG1
      8910DP41      9991DPG1
      8910DP12      9991DPG1
      8910DP22      9991DPG1
      8910DP32      9991DPG1
      8910DP42      9991DPG1
      8910DPA12    9991DPG1
      8910DPA13    9991DPG1
      8910DPA14    9991DPG2
      8910DPA22    9991DPG1
      8910DPA23    9991DPG1
      8910DPA24    9991DPG2
      8910DPA32    9991DPG1
      8910DPA33    9991DPG1
      8910DPA34    9991DPG2
      8910DPA42    9991DPG1
      8910DPA43    9991DPG1
      8910DPA44    9991DPG2
      8910DPA52    9991DPG2
      8910DPA53    9991DPG2
      8910DPA62    9991DPG3
      8910DPA63    9991DPG3
      8910DPA72    9991DPG3
      8910DPA73    9991DPG3
      8910DPA92    9991DPG4
      8910DPA93    9991DPG4
      8910DPA122  9991DPG4
      8910DPA123  9991DPG4
      8910SYD138  9991DPG5
      8910SYD230  9991DPG6

      What are the voltage and HP ranges for the ATV31C drive?

      Issue:
      Is there an option for 240vac 3 phase input and 3 phase output on the ATV31C drives?

      Product Line:
      Altivar ATV31C

      Environment:
      only ATV31C

      Cause:
      Needs to know if there is an option for 240vac 3 phase input 3 phase output.

      Resolution:
      There is not an option for 240vac 3 phase input and 3 phase output.  
      The ATV31C offers 1 phase input 240vac and 3 phase 240vac output .25HP to 3HP.
      The ATV31C offers 3 phase input 480vac and 3 phase 480vac output  .5HP to 20HP.

      Reference  the atv31c_installation manual_EN_V3
       

      Show More