Package 1 Bare Product Quantity
1
Product specific application
simple machine
Network number of phases
3 phases
[Us] rated supply voltage
200...480 V - 10...10 %
Motor power kW
- 15 kW, 3 phases at 400 V
- 7.5 kW, 3 phases at 230 V
Motor power hp
- 10 hp, 3 phases at 230 V
- 20 hp, 3 phases at 460 V
Utilisation category
AC-53B conforming to EN/IEC 60947-4-2
Current consumption
100 mA
Type of start
start with voltage ramp
Power dissipation in W
- 2.5 W at full load and at end of starting
- 322.5 W in transient state
Assembly style
with heat sink
Supply voltage limits
180...528 V
Supply frequency
50...60 Hz - 5...5 %
Network frequency
47.5...63 Hz
Output voltage
<= power="" supply="">=>
[Uc] control circuit voltage
24 V DC +/- 10 %
Starting time
- adjustable from 1 to 10 s
- 1 s / 50
- 10 s / 5
- 5 s / 10
Deceleration time symb
adjustable from 1 to 10 s
Starting torque
30...80 % of starting torque of motor connected directly on the line supply
Discrete input type
logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8="" ma="" 27="">=>
Discrete input voltage
24...40 V
Input output isolation
galvanic between power and control
Discrete input logic
positive LI1, LI2, BOOST at State 0: < 5="" v="" and=""><= 0.2="" ma="" at="" state="" 1:=""> 13 V, >= 0.5 mA=>
Discrete output type
- open collector logic LO1 end of starting signal
- relay outputs R1A, R1C NO
Discrete output voltage
24 V (voltage limits: 6...30 V) open collector logic
Minimum switching current
10 mA at 6 V DC for relay outputs
Maximum switching current
- relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive load
- relay outputs: 2 A at 250 V AC AC-15 cos phi = 0.5 and L/R = 20 ms inductive load
Maximum switching voltage
440 V relay outputs
Display type
- 1 LED (green) for starter powered up
- 1 LED (yellow) for nominal voltage reached
Tightening torque
- 1.9...2.5 N.m
- 0.5...0.5 N.m
Electrical connection
- 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit
- screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
- screw connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit
- 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit
- screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit
- screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit
- 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit
- screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit
- 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit
- 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit
Operating position
vertical +/- 10 degree
Power range
- 7...11 kW at 200...240 V 3 phases
- 15...25 kW at 380...440 V 3 phases
Motor starter type
soft starter
Electromagnetic compatibility
- conducted and radiated emissions level B conforming to CISPR 11
- immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
- voltage/current impulse level 3 conforming to IEC 61000-4-5
- conducted and radiated emissions level 3 conforming to IEC 61000-4-6
- immunity to conducted interference caused by radio-electrical fields conforming to IEC 61000-4-11
- conducted and radiated emissions level B conforming to IEC 60947-4-2
- damped oscillating waves level 3 conforming to IEC 61000-4-12
- electrostatic discharge level 3 conforming to IEC 61000-4-2
- EMC immunity conforming to EN 50082-1
- EMC immunity conforming to EN 50082-2
- harmonics conforming to IEC 1000-3-2
- harmonics conforming to IEC 1000-3-4
- immunity to electrical transients level 4 conforming to IEC 61000-4-4
Pollution degree
2 conforming to EN/IEC 60947-4-2
Vibration resistance
- 1 gn (f= 13-150 Hz) conforming to EN/IEC 60068-2-6
- 1.5 mm peak to peak (f= 3-13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
Operating altitude
- <= 1000="" m="" without="">=>
- > 1000 m with current derating of 2.2 % per additional 100 m
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Unit Type of Package 2
S03
Number of Units in Package 2
14
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins