Quantcast

Soft-Start Stop 6A 200 480V

Soft-Start Stop 6A 200 480V

Soft-Start Stop 6A 200 480V

Item Number: ATSU01N206LT

Retail
$1,238.74
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height234 mm

Depth icon

Depth150 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Altistart U01 and TeSys U

Product or component type

soft starter

Product destination

asynchronous motors

Warranty

18 months

Physical

Function available

integrated bypass

Marking

CE

Height

234 mm

Width

45 mm

Depth

150 mm

Net weight

0.34 kg

Standards

EN/IEC 60947-4-2

Product certifications

  • CCC
  • UL
  • C-Tick
  • CSA
    • IP degree of protection

      IP20

      Relative humidity

      5-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3

      Ambient air temperature for operation

    • -10-40 °C (without derating)
    • 40-50 °C (with current derating of 2 % per °C)
      • Ambient air temperature for storage

        -25-70 °C conforming to EN/IEC 60947-4-2

        REACh Regulation

        Free of Substances of Very High Concern above the threshold

        REACh free of SVHC

        Yes

        EU RoHS Directive

        Pro-active compliance (Product out of EU RoHS legal scope)

        Toxic heavy metal free

        Yes

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

        X

        Circularity Profile

        ENVEOLI100217EN

        California proposition 65

        WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

        Others

        Number of Units in Package 1

        1

        Number of Units in Package 2

        14

        Package 1 Height

        5.5 cm

        Package 1 Length

        17.2 cm

        Package 1 width

        15.5 cm

        Package 2 Height

        30 cm

        Package 2 Length

        40 cm

        Package 2 width

        30 cm

        Unit Type of Package 1

        PCE

        Unit Type of Package 2

        S03

        Product specific application

        simple machine

        Device short name

        ATSU01

        Network number of phases

        3 phases

        [Us] rated supply voltage

        200...480 V - 10...10 %

        Motor power kW

      • 3 kW, 3 phases at 400 V
      • 0.75 kW, 3 phases at 230 V
      • 2.2 kW, 3 phases at 400 V
      • 1 kW, 3 phases at 230 V
      • 1.5 kW, 3 phases at 400 V
        • Motor power hp

        • 1 hp, 3 phases at 230 V
        • 2 hp, 3 phases at 460 V
        • 3 hp, 3 phases at 460 V
        • 1.5 hp, 3 phases at 230 V
          • IcL starter rating

            6 A

            Utilisation category

            AC-53B conforming to EN/IEC 60947-4-2

            Current consumption

            65 mA

            Type of start

            start with voltage ramp

            Power dissipation in W

          • 1.5 W at full load and at end of starting
          • 61.5 W in transient state
            • Assembly style

              with heat sink

              Supply voltage limits

              180-528 V

              Supply frequency

              50...60 Hz - 5...5 %

              Network frequency

              47.5...63 Hz

              Output voltage

              <= power supply voltage

              [Uc] control circuit voltage

              24 V DC +/- 10 %

              Starting time

            • 1 s / 100
            • 5 s / 20
            • 10 s / 10
            • adjustable from 1 to 10 s
              • Deceleration time symb

                adjustable from 1 to 10 s

                Starting torque

                30...80 % of starting torque of motor connected directly on the line supply

                Discrete input type

                logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm

                Discrete input voltage

                24...40 V

                Input output isolation

                galvanic between power and control

                Discrete input logic

                positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA

                Discrete output current

              • 2 A DC-13
              • 3 A AC-15
                • Discrete output type

                • open collector logic LO1 end of starting signal
                • relay outputs R1A, R1C NO
                  • Discrete output voltage

                    24 V (voltage limits: 6...30 V) open collector logic

                    Minimum switching current

                    10 mA at 6 V DC for relay outputs

                    Maximum switching current

                  • relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive load
                  • relay outputs: 2 A at 250 V AC AC-15 cos phi = 0.5 and L/R = 20 ms inductive load
                    • Maximum switching voltage

                      440 V relay outputs

                      Display type

                    • 1 LED (green) for starter powered up
                    • 1 LED (yellow) for nominal voltage reached
                      • Tightening torque

                      • 1.9-2.5 N.m
                      • 0.5-0.5 N.m
                        • Electrical connection

                        • 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit
                        • screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
                        • screw connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit
                        • 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit
                        • screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit
                        • screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit
                        • 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit
                        • screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit
                        • 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit
                        • 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit
                          • Operating position

                            vertical +/- 10 degree

                            Power range

                          • 0.55-1 kW at 200-240 V 3 phases
                          • 1.1-2 kW at 380-440 V 3 phases
                          • 2.2-3 kW
                            • Motor starter type

                              soft starter

                              Electromagnetic compatibility

                            • conducted and radiated emissions level B conforming to CISPR 11
                            • immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
                            • voltage/current impulse level 3 conforming to IEC 61000-4-5
                            • conducted and radiated emissions level 3 conforming to IEC 61000-4-6
                            • immunity to conducted interference caused by radio-electrical fields conforming to IEC 61000-4-11
                            • conducted and radiated emissions level B conforming to IEC 60947-4-2
                            • damped oscillating waves level 3 conforming to IEC 61000-4-12
                            • electrostatic discharge level 3 conforming to IEC 61000-4-2
                            • EMC immunity conforming to EN 50082-1
                            • EMC immunity conforming to EN 50082-2
                            • harmonics conforming to IEC 1000-3-2
                            • harmonics conforming to IEC 1000-3-4
                            • immunity to electrical transients level 4 conforming to IEC 61000-4-4
                              • Pollution degree

                                2 conforming to EN/IEC 60947-4-2

                                Vibration resistance

                              • 1 gn (f= 13-150 Hz) conforming to EN/IEC 60068-2-6
                              • 1.5 mm peak to peak (f= 3-13 Hz) conforming to EN/IEC 60068-2-6
                                • Shock resistance

                                  15 gn for 11 ms conforming to EN/IEC 60068-2-27

                                  Operating altitude

                                • <= 1000 m without derating
                                • > 1000 m with current derating of 2.2 % per additional 100 m
                                  • Package 1 Weight

                                    454 g

                                    Package 2 Weight

                                    6.87 kg

                                    WEEE

                                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                    Show all specifications

                                    Documents & downloads

                                    hide show
                                    Filter items
                                    • All

                                    • CAD Files and Packs

                                    • Product Brochures

                                    • Technical Data Catalogues

                                    • End of Life Manual

                                    • Installation Instruction

                                    • Certificates (MSDS)

                                    • eTechPub

                                    • Declaration of Conformity

                                    Frequently Asked Questions

                                    hide show

                                    Does the ATS01 come with a shorting contactor?

                                    Issue:
                                    Does the ATS01 have an internal shorting contactor?

                                    Product Line:
                                    Altistat 01

                                    Environment:
                                    All

                                    Cause:
                                    N/A

                                    Resolution:
                                    All of the ALTISTART 01 models, except the ATS01N103FT and ATS01N106FT, have an internal shorting contactor as standard.

                                    Is the LH4N still available?

                                    Issue:
                                    LH4N availability

                                    Product Line:
                                    LH4N

                                    Environment:
                                    All models and all serial numbers

                                    Cause:
                                    Customer was looking for purchasing the LH4N112RT7.

                                    Resolution:
                                    No, the LH4N soft starter is obsolete. Please replace with the appropriate ATS01 or ATS22 soft starter. Consider application needs and features of currently-offered products.


                                     

                                    Are Softstarters acceptable for use in a Fire Pump applications?

                                    Issue:
                                    Softstarters for use in a Fire Pump applications

                                    Product line:
                                    Altistart 22 48 ATS22 ATS48

                                    Environment:
                                    all

                                    Cause:
                                    Fire pump systems typically require the motors to run until they fail, without faulting the controller

                                    Resolution:
                                    No. The softstarters are not rated for Fire pump requirements and does not meet the requirements.
                                     

                                    What are the adjustment ranges for the dials on an ATSU01N2..LT?

                                    For both the START TIME and STOP TIME dials, setpoint A is 1second and setpoint E is 10seconds.  There is a linear relationship from A to E setpoints.
                                    For the INITIAL VOLTAGE dial, setpoint A is 30% and setpoint E is 80% of full voltage.  There is a linear relationship from A to E setpoints.



                                    CTA-ID : 2061385

                                    Does Schneider offer a soft start for a single phase motor?

                                    Issue:
                                    Soft start for a single phase motor?

                                    Product Line:
                                    ATS01

                                    Environment:
                                    All

                                    Cause:
                                    Needs a soft starter for a single phase motor. 

                                    Resolution:
                                    Yes, but the offering is limited.  The ATS01N1**FT products are rated for single phase motors up to 2HP at 240V and 1/2HP at 120V.
                                    See the attachment beginning on page 34.  Reference page 40 for part number selection.

                                    What is the replacement for the High HP ATS01N softstarters?

                                    Issue:
                                    Part number for the replacement of the ATS01N High HP Soft Starters.

                                    Product line:
                                    ATS01, Altistart 01, High HP

                                    Environment:
                                    All models

                                    Cause:
                                    The launch of the ATS22 in 2011 caused the High HP units to become redundant.

                                    Resolution:

                                    The ATS01 High HP units were replaced with the ATS22 units.  These are functional replacements only.  The ATS01 had no overload protection, an internal power supply and simple dial adjustments.  The ATS22 will require external 120V or 230V power.  There are no dials to adjust, but the unit will need to be programmed.  See the ATS22 User Maual, document BBV51300 to review the wiring, dimensions and programming.

                                    ATS01N230LY - 32A rated.  Replaced by ATS22D32S6U
                                    ATS01N244LY - 44A rated.  Replaced by ATS22D47S6U
                                    ATS01N272LY - 72A rated.  Replaced by ATS22D75S6U
                                    ATS01N285LY - 85A rated.  Replaced by ATS22D88S6U

                                     
                                    Show More