ACES52G

Airflow Replacement Glass Diffuser To Suit Aces52 Fan

Catalogue Number: ACES52G
ACES52G
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
diffuser
Accessory / separate part category
replacement accessory
Material
glass
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

  • Corporate Marketing

Frequently Asked Questions

hide show

What is the part name for the glass diffuser on the ACES52R5L-BZ

The glass diffuser has an individual part name of ACES52G

is there a remote kit to suit the fan ACES52R5L available?

Yes the part number for a remote kit to suit the ACES52R5L is ACESR16K2.

Some of the key features are: 
  • 16 Channel
  • For ACES52 Fan
  • Light and fan control
  • IR remote
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=ACESR16K2


What is part number for replacement blades to suit ACES56 fan?

The part number for replacement blades to suit is a ACES56B-WE.

What would be the part number for a remote kit to suit an ACES36AL-WE ?

The Part number for the remote kit would be an ACESR16K1.
It is programmable so 1 remote can turn on multiple fans or programmed completely separate.
It also comes with wall mountable cradle so you do not loose the remote and it stores neatly away.
Suits all ACES36, ACES48 and ACES56 fans.
For more information on this product please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=acesr16k1

What is the warranty for ACES36JAL, ACES48JAL, ACES56JAL, ACES48J, ACES56J, ACES36AL, ACES48AL, ACES56AL, ACES48 and ACES56 ceiling sweep fans?

The benefits conferred by this warranty are in addition to all implied warranties, other rights and remedies in respect of the product which the consumer has under the Trade Practices Act and similar State and Territory Laws.

The original purchaser of this Airflow Ceiling Sweep Fan is provided with the following warranty, subject to the following conditions: Schneider (Australia) Pty Ltd warrants this product for a period of three years from the date of purchase for all parts defective in workmanship or materials.

All products used in commercial applications are limited to a 90-day warranty. All defective parts will be replaced free of charge. The following exclusions do not preclude the purchaser from those statutory rights consumers have under the Trade Practices Act or similar State and Territory Laws.

 

Is there a replacement glass for the light on a ACES52W5L fan?

Yes, the part number for the replacement glass to suit the light on a ACES52W5L fan is a ACES52G.

For further information please visit https://www.clipsal.com/Trade/search-results?q=aces52g

 

What is part number for remote kit to suit 3HS1400AL?

The part number for remote kit to suit is a ACESR16K1.
Some of the key features are:
  • 16 Channel
  • For ACES36, ACES48, ACES56 Fans
For more information refer to the following link: https://www.clipsal.com/Trade/Products/ProductDetail?catno=ACESR16K2

What is the part number for replacement blades for Ceiling fan , ACES48?

The part number for replacement blades for Ceiling fan , ACES48 is - 3B1200AL

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3B1200AL
 

What type of Communication Modules are available for the SEPAM Relays

Issue    
Which types of communications Modules are available for the SEPAM Relays?

Product Line    
SEPAM Communications

Environment    
Networking and communications

Resolution  
The protocols that are available are: DNP3, Modbus RTU, IEC 60870-5-103, Modbus TCP/IP, and IEC61850.
Not all modules have the same type of protocols or type of communications.
Attached is the communication accessory selection guide to help pick the correct module.

Can the ACES48L fan be controlled by the remote while the light is operated from a wall switch?

Yes, it can be controlled in various ways purely dependant on the wiring.

For further information please visit Trade - Clipsal by Schneider Electric

Where can I find the CE marking declaration for ACE850?

You will find in attachment the CE marking declaration for ACE858TP and ACE850FO.

AEDL3

Where may the ACE850 be configured?

The Sepam relay must be configured to accept the ACE850 before configuration of the device may occur. To enable the ACE850, connect to the Sepam relay via SFT2841 and select ethernet from the General Characteristics screen. Once ethernet is selected the ... box will be available to click. Click this box to open a menu allowing for the configuration of the IP, subnet mask, and Gateway information. Further configuration of the ACE850 may be done from the web interface for the module. To access the web interface, open Internet Explorer and type in the IP address of the ACE850, sign in and configure the necessary parameters.

What does the IP filtering do in an ACE850 module?

By enabling the IP filtering in the module,it allows those specific IP addresses to access the module. The IP addresses can also be restricted to which module can access the ACE850. The different modules are ICE61850 and SFT2841 or both. This will provide a very secure webpage.

AEDL3


Legacy KB System (APS) Data: RESL204866 V1.0, Originally authored by MiZe on 03/19/2011, Last Edited by MiZe on 03/19/2011
Related ranges: Sepam accessories

Can the ACE850 be used to communicate with both IEC61850 and Modbus TCP/IP simultaneously?

Issue    
Customer would like to use both IEC61850 protocol and Modbus TCP/IP simultaneously.

Product Line    
SEPAM, ACE850TP, ACE850FO

Environment    
Communications over network

Resolution  
The ACE850 communication module can be used for simultaneous communication of IEC61850 and Modbus TCP/IP protocols. This procedure is supported and recommended.



 

How to Change the NDSCOM and the TEST parameters on a SEPAM 80 with an ACE850 module.

NDSCOM is a parameter that is not supported with the SEPAM 80 with an ACE850. The TEST parameter may be modified via the GOOSE messaging statistics found by logging into the ACE850 device. The TEST parameter will allow the GOOSE messaging system to be tested without affecting anything else. The software that we provide to help create GOOSE messaging communications within the SEPAM is the CET850 (replacement of previous SFT850). CET850 will create all of the necessary files that are associated with GOOSE messaging and will also allow these files to be easily modified by a third party software such as IECBrowser and IEDScout.

What is the default username and password for the ACE850?

Issue
A user would like to know the default username and password used to log on into ACE850FO/ACE850TP

Product Line
ACE850FO/ACE850TP 

Environment
Login credentials

Cause
Appropriate credential is required to login into ACE850FO/ACE850TP

Resolution
The default administrator username and password for the ACE850FO/ACE850TP is shown below:
Username : Admin
Password : ACE850

ADEL3


 
Legacy KB System (APS) Data: RESL211183 V1.0, Originally authored by DaFr on 04/11/2013, Last Edited by DaFr on 04/11/2013
Related ranges: Sepam accessories

Is there a pinout for the SEPAM CCA612 cable?

Issue
User is looking for a detailed pinout for the CCA612 612 Connection cable. The CCA612 cable is used to connect the  ACE949-2, ACE959, ACE937,
ACE969TP-2 and ACE969FO-2 communication interfaces to the SEPAM.

Product Line
SEPAM 20/40/60/80 series

Resolution
The CCA612 is a proprietary cable and a pinout diagram is not available. However for testing and troubleshooting purposes only, a shielded CAT 5 cable can be used as an alternative. The catalog reference number for a 3 meter (9.8 ft) long CCA612 cable is 59663.
* Only use a CAT 5 cable for temporarily testing and troubleshooting purposes.*