Range
Acti9
Product name
Acti9 PowerTag Link
Product or component type
smart communication module
Device short name
PowerTag Link C
Device application
  • basic energy metering
  • load alarming
    • Connected auxiliaries
      up to 20 wireless devices
      [Us] rated supply voltage
      110...230 V AC + 15 %
      Supply voltage limits
      19.2-28.8 V
      Connectivity to devices
      wireless energy sensor
      Upstream connectivity
      cloud
      Communication service
      Ethernet
      Transmission support medium
      radio frequency 2.4-2.4835 GHz PowerTag 20
      User interface
      smartphone app
      Protection type
    • overvoltage at 0.5 kV for auxiliary supply
    • overvoltage at 1 kV for ETHERNET
      • Immunity to microbreaks
        10 ms
        Reset
        factory reset on front face
        Inrush current
        3 A
        Mounting position
        horizontal/vertical on DIN rail
        Location of connection
        upstream
        Connections - terminals
      • RJ45 connector qty: 1 for ETHERNET, ordered separately
      • plug-in connector qty: 1 for supply circuit
        • Clamping connection capacity
        • 0.2...1.5 mm², flexible for supply circuit
        • 0.2...1.5 mm², flexible with ferrule for supply circuit
        • 0.2...1.5 mm², rigid for supply circuit
          • Wire stripping length
            supply circuit: 7 mm
            Overvoltage category
            III
            9 mm pitches
            6 useful
            Height
            85 mm
            Width
            54 mm
            Depth
            62 mm
            Net weight
            133 g
            Range compatibility
          • PowerTag
          • PowerTag
            • Commissioning protocol
              Bluetooth
              Commissioning interface
              mySchneider Electrician eSetup
              End user smartphone application
              EcoStruxure Facility Expert Small Business
              Compatibility code
              Acti9 PowerTag Link C
              IP degree of protection
            • IP20
            • IP40 (modular enclosure)
              • Pollution degree
                2
                Electromagnetic compatibility
              • resistance to electrostatic discharge (air discharge), 8 kV, conforming to IEC 61000-4-2
              • resistance to electrostatic discharge (contact discharge), 4 kV, conforming to IEC 61000-4-2
              • resistance to radiated electromagnetic fields (80 MHz...3 GHz), 10 V/m, conforming to IEC 61000-4-3
              • communication bus: resistance to fast transient, 1 kV, conforming to IEC 61000-4-4
              • power supply: resistance to fast transient (5...100 kHz), 2 kV, conforming to IEC 61000-4-4
              • conducted EMC (0.15...80 MHz), 10 V, conforming to IEC 61000-4-6
              • immunity to magnetic fields at network frequency (continuous), 30 A/m, conforming to IEC 61000-4-8
              • immunity to magnetic fields at network frequency (pulsed), 100 A/m, conforming to IEC 61000-4-8
              • radiated emission (30...1000 MHz), class A, conforming to IEC 61131-3 Ed.3
              • conducted emission (0.15...30 MHz), class A, conforming to IEC 61131-2
                • Environmental characteristic
                • corrosive 3C2 conforming to IEC 60721-3-3
                • salt mist 2 conforming to IEC 60068-2-52
                  • Vibration resistance
                    1 gn, amplitude = 3.5 mm (f = 5-300 Hz)10 cycles conforming to IEC 60068-2-6
                    Shock resistance
                    15 gn for 11 ms conforming to IEC 60068-2-27
                    Fire resistance
                  • other parts: 650 °C ( 30 s ) conforming to IEC 60695-2
                  • on connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2
                    • Tropicalisation
                      2 conforming to IEC 60068-2
                      Relative humidity
                      93-93 % at 40-40 °C
                      Operating altitude
                    • 0...2000 m operating
                    • 0...3000 m storage
                      • Ambient air temperature for operation
                        -25-55 °C
                        Ambient air temperature for storage
                        -40-85 °C
                        Standards
                      • EN 300-328
                      • EN 301-489-1
                      • EN 301-489-17
                      • EN/IEC 60950-1
                        • Sustainable offer status
                          Green Premium product
                          REACh Regulation
                          Reference contains Substances of Very High Concern above the threshold
                          EU RoHS Directive
                          Compliant
                          Mercury free
                          Yes
                          RoHS exemption information
                          Yes
                          China RoHS Regulation
                          Product out of China RoHS scope. Substance declaration for your information
                          Environmental Disclosure
                          ENVPEP1604024
                          Circularity Profile
                          ENVEOLI1604024
                          WEEE
                          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins