Add-on block; Vigi iC60 63A 3PPN

Acti9 iC60 Earth Leakage Add-on Block, 3P + N, 63A, 300mA, A Type

Catalogue Number: A9V06763
Add-on block; Vigi iC60 63A 3PPN
Retail
$1,581.58
RRP (Inc. GST)

Specifications

hide show
Range
Acti 9
Range of product
iC60
Product or component type
add-on residual current devices
Device short name
Vigi iC60
Poles description
3P + N
Neutral position
left
[In] rated current
63 A
Earth-leakage sensitivity
300 mA
Earth-leakage protection time delay
instantaneous
Earth-leakage protection class
type A
Network type
AC
Network frequency
50/60 Hz
[Ue] rated operational voltage
  • 400 V AC 50/60 Hz conforming to EN 61009-1
  • 415 V AC 50/60 Hz conforming to IEC 61009-1
    • Standards
    • EN 61009-1
    • IEC 61009-1
      • 9 mm pitches
        6
        Device location in system
        outgoer
        Residual current tripping technology
        voltage independent
        [Ui] rated insulation voltage
        500 V AC 50/60 Hz conforming to IEC 60947-2
        [Uimp] rated impulse withstand voltage
        6 kV conforming to IEC 60947-2
        Range compatibility
        Acti 9 iC60
        Product compatibility
        single terminal
        Local signalling
        trip indicator
        Mounting mode
        clip-on
        Mounting support
        DIN rail
        Electrical connection to mcb
        by screws
        Comb busbar and distribution block compatibility
        bottom: YES
        Height
        91 mm
        Width
        108 mm
        Depth
        73.5 mm
        Net weight
        0.245 kg
        Connections - terminals
      • tunnel type terminal downside for 1 cable(s) 1-35 mm² rigid without cable end
      • tunnel type terminal downside for 1 cable(s) 1-25 mm² flexible without cable end
      • tunnel type terminal downside for 1 cable(s) 1-25 mm² flexible with cable end
        • Wire stripping length
          14 mm for bottom connection
          Tightening torque
          3.5-3.5 N.m bottom
          IP degree of protection
        • IP20 conforming to IEC 60529
        • IP40 (modular enclosure) conforming to IEC 60529
          • Pollution degree
            3 conforming to IEC 60947-2
            Electromagnetic compatibility
            8/20 µs impulse withstand, 250 A conforming to IEC 61009-1
            Ambient air temperature for operation
            -5-60 °C
            Ambient air temperature for storage
            -40-85 °C
            Sustainable offer status
            Green Premium product
            REACh Regulation
            Free of Substances of Very High Concern above the threshold
            EU RoHS Directive
            Compliant
            Mercury free
            Yes
            RoHS exemption information
            Yes
            China RoHS Regulation
            Product out of China RoHS scope. Substance declaration for your information
            Environmental Disclosure
            ENVPEP1409017EN
            WEEE
            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
            Warranty
            18 months

            Frequently Asked Questions

            hide show

            Do you do a 3 pole version of a 4RCBM232/30?

            Unfortunately we do not offer a 3 pole version of a 4RCBM230/30.

            However as an alternative we can offer a A9F54432 (4 Pole 32A Circuit Breaker) and a A9V06763 (Vigi Block).

            For further information please visit www.clipsal.com/Trade

            Is there a shunt trip that can be used in conjunction with a iSW series?

            No unfortunately the ISW series can't be used with shunt release.

            For further information please visit Global Specialist in Energy Management | Schneider Electric

            What is the suitable vigi unit to suit with the A9F54332?

            A9F54332 is a 3 pole breaker.
            They have an option of having 3 pole vigi (A9V51363) or 4 pole vigi (A9V02763) for neutral conection .

            What is a 1 pole 20 amp "D" curve RCBO?

            Use a 1 pole 20 amp "D" curve breaker A9F55120 and add the vigi unit A9V02663 to make the Combo ...(now 3 poles wide)
            https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F55120
            and vigi
            https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9V02663

            User-added image
             User-added image

            what is the Australian replacement for a A9C20663?

            The replacement is a Acti 9 A9C20863

            How can I make 1 Pole 10 Amps B Curve 30mA RCBO?

            To make 1 Pole 10 Amps B Curve 30mA RCBO, you need the following:
            A9F53110 - 1 Pole 10 Amps B Curve Breaker (https://www.schneider-electric.com.au/en/search/A9F53110)
            +
            A9V02663 - 2 Pole 30mA 63 Amps Add-on Vigi to suit 1 Pole iC60 Breakers (https://www.schneider-electric.com.au/en/search/A9F53110)

            Please note the total width of this combination will be equal to 3 Poles standard RCBO (3 x 18mm)

            Is there an alternative for a 1 module RCD-MCB part number 4RCBE116/30D?

            Yes, however it is larger in size as it requires 4 modules. The replacement part numbers are A9F55116 + A9V02663.

            Is A9A27006 suitable to use on A9S66463?

            Yes, A9A27006 is suitable to use on A9S66463