Quantcast

Acti 9 Switch Disconnector iSW, 1P, 125A, 240V

Acti 9 Switch Disconnector iSW, 1P, 125A, 240V

Acti 9 Switch Disconnector iSW, 1P, 125A, 240V

Item Number: A9S66192

Retail
$162.47
RRP (Inc. GST)

Product Dimensions

Width icon

Width18 mm

Height icon

Height85 mm

Depth icon

Depth73 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

iSW 40...125

Range

Acti 9

Product or component type

switch disconnector

Device application

  • control
  • isolation
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      [Ie] rated operational current

      125 A at 240 V AC 50/60 Hz

      [Ue] rated operational voltage

      240 V AC 50/60 Hz

      Control type

      toggle

      Local signalling

      ON/OFF indication

      Mounting mode

      fixed

      Mounting support

      DIN rail

      Height

      85 mm

      Width

      18 mm

      Depth

      73 mm

      Mechanical durability

      20000 cycles

      Electrical durability

      2500 cycles

      Connections - terminals

    • tunnel type terminals (top or bottom) - <= 1 x 50 mm² - rigid
    • tunnel type terminals (top or bottom) - <= 1 x 35 mm² - flexible
    • tunnel type terminals (top or bottom) - <= 1 x 35 mm² - flexible with ferrule
      • Wire stripping length

        9 mm

        Standards

      • AS 60947-3
      • IEC 60947-3
      • EN 60947-3
      • NZS 60947-3
      • BS EN 60947-3
        • IP degree of protection

          IP20

          Relative humidity

          95-95 % at 55-55 °C

          Ambient air temperature for operation

          -25-60 °C

          Ambient air temperature for storage

          -40-85 °C

          REACh free of SVHC

          Yes

          EU RoHS Directive

          Compliant

          Toxic heavy metal free

          Yes

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

           Pro-active China RoHS declaration (out of China RoHS legal scope)

          Environmental Disclosure

          ENVPEP121216EN

          Others

          Product name

          Acti 9 iSW

          Device short name

          iSW

          Poles description

          1P

          Utilisation category

          AC-22A

          Suitability for isolation

          yes

          [Icm] rated short-circuit making capacity

          5 kA switch-disconnector alone

          [Icw] rated short-time withstand current

          1500 A

          [Ui] rated insulation voltage

          250 V AC 50/60 Hz

          [Uimp] rated impulse withstand voltage

          6 kV

          Contact position indicator

          yes

          Comb busbar and distribution block compatibility

          top or bottom: YES

          Connection pitch

          9 mm pitches

          2

          Tightening torque

          3.5 N.m

          Compatibility code

          iSW

          Pollution degree

          3

          Tropicalisation

          2

          Unit Type of Package 1

          PCE

          Number of Units in Package 1

          1

          Package 1 Weight

          95 g

          Package 1 Height

          7.85 cm

          Package 1 width

          1.8 cm

          Package 1 Length

          9.2 cm

          WEEE

          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
          Show all specifications

          Documents & downloads

          hide show
          Filter items
          • All

          • Product Brochures

          • CAD Files and Packs

          • Technical Data Catalogues

          • Product Environmental

          • Declaration of Conformity

          Frequently Asked Questions

          hide show

          Is there a shunt trip that can be used in conjunction with a iSW series?

          No unfortunately the ISW series can't be used with shunt release.

          For further information please visit Global Specialist in Energy Management | Schneider Electric

          What is the new code for 15005?

          The new code is A9S60120

          Does the A9A26981 fit on the A9S66163?

          Yes, that is designed to fit on the Acti9 shaped devices including the iSW switches.

          Is A9A27006 suitable to use on A9S66463?

          Yes, A9A27006 is suitable to use on A9S66463

           

          What is the part code for a 3 pole din rail mount main switch

           What curent rating ?
          The part code is 3 pole 40amp mains Isolating switch is A9S66340 or Domae DCK12646 63amp 3 pole

          Java Cryptography Extension requirement for SNMPv3 configuration in PowerChute Network Shutdown and PowerChute Business Edition

          Issue:
          In certain geographies it is necessary to install the Java Cryptography Extension to use privacy protocols AES-192 or AES-256 in the PowerChute Network Shutdown and PowerChute Business Edition SNMPv3 configuration.
             
          Product Line:
          PowerChute Network Shutdown v4.2 or higher and PowerChute Business Edition v9.5


          Environment: 
          All
          supported operating systems

          Solution:

          Due to the import control restrictions of some countries, the version of the Java Cryptography Extension (JCE) policy files that are bundled with the Java Runtime Environment 8 (JRE 8) allow ‘strong’ but limited cryptography to be used; they have in-built restrictions on available cryptographic strength. Depending on your geographical location (e.g. outside of the United States), to use the privacy protocol AES-192 or AES-256 in PowerChute SNMPv3 configuration, it may be necessary to first download and install the Unlimited Strength Java™ Cryptography Extension (JCE) Policy Files available from the Oracle website (
          https://www.oracle.com/technetwork/java/javase/downloads/index.html).
          The Unlimited Strength JCE contains no restrictions on cryptographic strengths.
           
          NOTE: It is recommended to consult your export/import control counsel or legal counsel to determine the exact cryptographic strength required for your geographical jurisdiction.
           

          Steps for PowerChute Business Edition v9.5:

          Windows:
          1. Download and extract the Unlimited Strength Jurisdiction Policy Files available on the Oracle website.
          2. Navigate to the installed directory of PowerChute. If the default location was chosen during installation, this will be C:\Program Files\APC\PowerChute Business Edition or C:\Program Files (x86)\APC\PowerChute Business Edition depending on your operating system.
          3. Navigate to \jre1.8.0_144\lib\security and replace the existing Policy Files with the ones extracted in Step 1.
          Note: If you change the JRE used with PowerChute via the JRE Configuration Tool, the existing Policy Files will be in \JreConfigTool\<JRE>\lib\security\policy\unlimited. However, the Policy Files extracted in Step 1 must be copied to the \JreConfigTool\<JRE>\lib\security\ directory. For example: \JreConfigTool\1.8.0_152\lib\security.
          1. Restart the PCBE service.
           
          Linux:
          1. Download and extract the Unlimited Strength Jurisdiction Policy Files available on the Oracle website.
          2. Navigate to the installed directory of PowerChute. If the default location was chosen during installation, this will be /opt/APC/PowerChuteBusinessEdition.
          3. Navigate to \jre1.8.0_144\lib\security and replace the existing Policy Files with the ones extracted in Step 1.
          NOTE: If you change the JRE used with PowerChute via the JRE Configuration Tool, navigate to the installed directory of the JRE. For example, if the JRE is stored on your desktop, this will be /root/Desktop/<JRE> (e.g. /root/Desktop/jre1.8.0_152). The existing Policy Files will be in /<JRE>/lib/security/policy/unlimited. However, the Policy Files extracted in Step 1 must be copied to the /<JRE>/lib/security directory.
          1. Restart the PCBE service.
          NOTE: If you change the JRE used with PowerChute via the JRE Configuration Tool, an additional step must be performed after Step 3 to edit the java.security file in the security directory. See Knowledge Base article FA333166 on the APC website for more information.
           
          NOTE: This issue has been resolved in PowerChute Business Edition v10.x which is available to download on the APC website.
           
          Show More