iID  Differential switches  25/100A 4P

Acti 9 iID, RCCB, 4P, 63A, 30mA, Type A

Catalogue Number: A9R51463
iID  Differential switches  25/100A 4P
Retail
$716.07*
RRP (Inc. GST)

Specifications

hide show
Range of product
iID
Range
Acti 9
Product name
Acti 9 iID
Product or component type
residual current circuit breaker (RCCB)
Device short name
iID
Poles description
4P
Neutral position
left
[In] rated current
63 A
Network type
AC
Earth-leakage sensitivity
30 mA
Earth-leakage protection time delay
instantaneous
Earth-leakage protection class
type A
Device location in system
outgoer
Network frequency
50/60 Hz
[Ue] rated operational voltage
380...415 V AC 50/60 Hz
Residual current tripping technology
voltage independent
Rated breaking and making capacity
  • Idm 1500 A
  • Im 1500 A
    • Rated conditional short-circuit current
      10 kA
      [Ui] rated insulation voltage
      500 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      6 kV
      Surge current
      250 A
      Contact position indicator
      yes
      Control type
      toggle
      Mounting mode
      clip-on
      Mounting support
      DIN rail
      Comb busbar and distribution block compatibility
      top or bottom: tooth
      Connection pitch
      9 mm pitches
      8
      Height
      91 mm
      Width
      72 mm
      Depth
      73.5 mm
      Net weight
      0.37 kg
      Mechanical durability
      20000 cycles
      Electrical durability
      AC-1: 15000 cycles
      Locking options description
      padlocking device
      Connections - terminals
    • single terminal top or bottom 1-35 mm² rigid
    • single terminal top or bottom 1-25 mm² flexible
    • single terminal top or bottom 1-25 mm² flexible with ferrule
      • Wire stripping length
        14 mm for top or bottom connection
        Tightening torque
        3.5-3.5 N.m top or bottom
        Compatibility code
        iID
        Standards
        EN/IEC 61008-1
        IP degree of protection
      • IP20 conforming to IEC 60529
      • IP40 (modular enclosure) conforming to IEC 60529
        • Pollution degree
          3
          Electromagnetic compatibility
          8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
          Ambient air temperature for operation
          -25-60 °C
          Ambient air temperature for storage
          -40-85 °C
          Sustainable offer status
          Green Premium product
          REACh Regulation
          Free of Substances of Very High Concern above the threshold
          EU RoHS Directive
          Compliant
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          Product out of China RoHS scope. Substance declaration for your information
          Environmental Disclosure
          ENVPEP1409014EN
          WEEE
          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
          Warranty
          18 months

          Frequently Asked Questions

          hide show

          Old Merlin Gerin Code 23382 4p 40amp 30ma RCCB is now ?

          Code now is A9R51440

          What is the Australian equivalent for the A9R41263

          For a Type A RCCB, the following part name will be suitable: A9R51263
          For a Type AC RCCB, the following part name will be suitable: A9R41263

          What is the suitable vigi unit to suit with the A9F54332?

          A9F54332 is a 3 pole breaker.
          They have an option of having 3 pole vigi (A9V51363) or 4 pole vigi (A9V02763) for neutral conection .

          What is the replacement code for a Merlin Gerin 23332 ?.

          The current equivalent is the A9R91440

          What is kA rating for A9R91440 ?

          The A9R91440 is Rated 10kA

           

          What is the part number for a 3phase 100amp 30mA trip RCD unit?

          The part number for a 3 phase  ,100amp , 30mA trip RCD unit is - A9R21491

          What is the replacement for the Merlin Gerin 23332?

          A9R91440

          What do I need to put together a single phase 30A 56 Series RCD

          Use 56CB4 + A9R51240 40amp RCCB

          What is the code of the Domae version of a 23358 40A 2p RCCB?

          It is a DOM16695

          Is the Acti 9 range of RCCB 120v ac rated?

          All Acti9 RCCB's are rated 230-240v AC only

          Is A9A27006 suitable to use on A9S66463?

          Yes, A9A27006 is suitable to use on A9S66463

           

          What is the part number for 300mA sensitivity RCCB, in 63amp?

          The part number will be A9R25263.
          For more specifications please follow the below link,
          https://www.schneider-electric.co.uk/en/product/A9R25263/iid---rccb---2p---63a----300ma----a-type/
          Image result for A9R25263 schneider


           
          Show More