iID   Differential switches 2P

Acti 9 Lid, RCCB, 2P, 63A, 300mA, S - Type A-SI

Catalogue Number: A9R35263
iID   Differential switches 2P
Retail
$1,277.25
RRP (Inc. GST)

Specifications

hide show
Range of product
iID
Range
Acti 9
Product name
Acti 9 iID
Product or component type
residual current circuit breaker (RCCB)
Device short name
iID
Poles description
2P
Neutral position
left
[In] rated current
63 A
Network type
AC
Earth-leakage sensitivity
300 mA
Earth-leakage protection time delay
selective
Earth-leakage protection class
type A-SI
Device location in system
outgoer
Network frequency
50/60 Hz
[Ue] rated operational voltage
220...240 V AC 50/60 Hz
Residual current tripping technology
voltage independent
Rated breaking and making capacity
  • Idm 1500 A
  • Im 1500 A
    • Rated conditional short-circuit current
      10 kA
      [Ui] rated insulation voltage
      500 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      6 kV
      Contact position indicator
      yes
      Control type
      toggle
      Mounting mode
      clip-on
      Mounting support
      DIN rail
      Comb busbar and distribution block compatibility
      top or bottom: tooth
      Connection pitch
      9 mm pitches
      4
      Height
      91 mm
      Width
      36 mm
      Depth
      73.5 mm
      Net weight
      0.21 kg
      Mechanical durability
      20000 cycles
      Electrical durability
      AC-1: 15000 cycles
      Locking options description
      padlocking device
      Connections - terminals
    • single terminal top or bottom 1-35 mm² rigid
    • single terminal top or bottom 1-25 mm² flexible
    • single terminal top or bottom 1-25 mm² flexible with ferrule
      • Wire stripping length
        14 mm for top or bottom connection
        Tightening torque
        3.5-3.5 N.m top or bottom
        Market segment
        small commercial
        Compatibility code
        iID
        Standards
        EN/IEC 61008-1
        Product certifications
        EAC
        IP degree of protection
      • IP20 conforming to IEC 60529
      • IP40 (modular enclosure) conforming to IEC 60529
        • Pollution degree
          3
          Electromagnetic compatibility
          8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61008-1
          Ambient air temperature for operation
          -25-60 °C
          Ambient air temperature for storage
          -40-85 °C
          Unit Type of Package 1
          PCE
          Number of Units in Package 1
          1
          Package 1 Weight
          210 g
          Package 1 Height
          4 cm
          Package 1 width
          8 cm
          Package 1 Length
          9.6 cm
          Unit Type of Package 2
          BB1
          Number of Units in Package 2
          6
          Package 2 Weight
          1.299 kg
          Package 2 Height
          9 cm
          Package 2 width
          10.2 cm
          Package 2 Length
          25.5 cm
          Unit Type of Package 3
          S03
          Number of Units in Package 3
          54
          Package 3 Weight
          12.214 kg
          Package 3 Height
          30 cm
          Package 3 width
          30 cm
          Package 3 Length
          40 cm
          Sustainable offer status
          Green Premium product
          EU RoHS Directive
          Compliant
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          Product out of China RoHS scope. Substance declaration for your information
          Environmental Disclosure
          ENVPEP1409014EN
          WEEE
          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
          Warranty
          18 months

          Frequently Asked Questions

          hide show

          Width of D Curve 2 Pole MCB, 6kA, 63A?

          A9F45263 - 2p = 36mm

          What is the part number for 300mA sensitivity RCCB, in 63amp?

          The part number will be A9R25263.
          For more specifications please follow the below link,
          https://www.schneider-electric.co.uk/en/product/A9R25263/iid---rccb---2p---63a----300ma----a-type/
          Image result for A9R25263 schneider


           

          What is the Australian equivalent for the A9R41263

          For a Type A RCCB, the following part name will be suitable: A9R51263
          For a Type AC RCCB, the following part name will be suitable: A9R41263

          Is there a shunt trip that can be used in conjunction with a iSW series?

          No unfortunately the ISW series can't be used with shunt release.

          For further information please visit Global Specialist in Energy Management | Schneider Electric

          What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

           
           

          A9D33620 = SI (Super Immunised)
          A9D32620 = Type A (AC or pulsating DC)

          Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
          Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.