C120H 2P 63A�125A; Miniature Circuit Breaker

Acti 9 C120H Circuit Breaker, 2P, 63A, 415V, D Curve

Catalogue Number: A9N18500
C120H 2P 63A�125A; Miniature Circuit Breaker
Retail
$617.51
RRP (Inc. GST)

Specifications

hide show
Range of product
C120
Range
Acti 9
Product name
C120
Product or component type
miniature circuit-breaker
Device short name
C120H
Device application
distribution
Poles description
2P
Number of protected poles
2
Neutral position
left
[In] rated current
63 A at 30 °C
Network type
AC
Trip unit technology
thermal-magnetic
Curve code
D
Breaking capacity code
H
Breaking capacity
  • 15000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1
  • 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 15 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
  • 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • Suitability for isolation
      yes conforming to IEC 60947-2
      Network frequency
      50/60 Hz
      [Ue] rated operational voltage
    • 380...415 V AC 50/60 Hz
    • 220...240 V AC 50/60 Hz
    • 440 V AC 50/60 Hz
    • <= 250 V DC
    • 230...400 V AC 50/60 Hz
      • Magnetic tripping limit
        10...14 x In
        [Ics] rated service breaking capacity
      • 7500 A 50 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz
      • 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
      • 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz
      • 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz
      • 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
        • Limitation class
          3 conforming to EN/IEC 60947-2
          [Ui] rated insulation voltage
          500 V AC 50/60 Hz conforming to EN/IEC 60947-2
          [Uimp] rated impulse withstand voltage
          6 kV conforming to EN/IEC 60947-2
          Contact position indicator
          yes
          Control type
          toggle
          Local signalling
          ON/OFF indication
          Mounting mode
          clip-on
          Mounting support
          35 mm symmetrical DIN rail
          Comb busbar and distribution block compatibility
          YES
          Connection pitch
          9 mm pitches
          6
          Height
          81 mm
          Width
          54 mm
          Depth
          73 mm
          Net weight
          0.41 kg
          Mechanical durability
          20000 cycles
          Electrical durability
          10000 cycles conforming to IEC 60947-2
          Connections - terminals
        • tunnel type terminals1-50 mm² rigid
        • tunnel type terminals1.5-35 mm² flexible
          • Wire stripping length
            15 mm
            Tightening torque
            3.5-3.5 N.m
            Earth-leakage protection
            separate block
            Compatibility code
            C120
            Market segment
          • residential
          • small commercial
            • Standards
            • EN/IEC 60898-1
            • EN/IEC 60947-2
              • Product certifications
                EAC
                IP degree of protection
                IP20 conforming to IEC 60529
                Pollution degree
                3 conforming to IEC 60947-2
                Overvoltage category
                IV
                Tropicalisation
                2 conforming to IEC 60068-1
                Relative humidity
                95-95 % at 55-55 °C
                Operating altitude
                2000 m
                Ambient air temperature for operation
                -30-60 °C
                Ambient air temperature for storage
                -40-70 °C
                Unit Type of Package 1
                PCE
                Number of Units in Package 1
                1
                Package 1 Weight
                376 g
                Package 1 Height
                5.3 cm
                Package 1 width
                6.8 cm
                Package 1 Length
                8.4 cm
                Unit Type of Package 2
                BB1
                Number of Units in Package 2
                6
                Package 2 Weight
                2.322 kg
                Package 2 Height
                10 cm
                Package 2 width
                9 cm
                Package 2 Length
                33 cm
                Unit Type of Package 3
                S03
                Number of Units in Package 3
                36
                Package 3 Weight
                14.419 kg
                Package 3 Height
                30 cm
                Package 3 width
                30 cm
                Package 3 Length
                40 cm
                Sustainable offer status
                Green Premium product
                REACh free of SVHC
                Yes
                EU RoHS Directive
                Compliant
                Toxic heavy metal free
                Yes
                Mercury free
                Yes
                RoHS exemption information
                Yes
                China RoHS Regulation
                 Pro-active China RoHS declaration (out of China RoHS legal scope)
                Environmental Disclosure
                ENVPEP121230EN
                WEEE
                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                Warranty
                18 months

                Frequently Asked Questions

                hide show

                Wanted to know if A9N18524 can be used as 3 pole breaker instead of 4 pole?

                Yes, customer can use the 3 pole and leave 4 pole open.

                If a 3 pole 63A ,D curve 10kA MCB is no longer available in the C120 frame - what can I use instead?



                Code = A9N18511  3 pole, 15kA, 63A, (27mm wide)   

                Are the A9N18359 and A9A26924 compatible?

                The ref A9N18359 is C120 MCB (Multi9 design in the white material).

                The ref A9A26924 is iOF auxiliary (Aciti9 design for iC60 MCB).

                I can confirm that the parts A9N18359 and A9A26924 are not compliant with each other

                 

                What is the new code for the 18364?

                The new code is now A9N18364

                What is the part number for a B curve 125A 3P breaker

                The part number is A9N18426

                How many poles wide is the iC120 3 pole 80amp C/B - A9N18365?

                The A9N18365 is 3 pole wide but is 27mm per pole , thus meaning it will need a 4.5 pole wide enclosure 81mm
                For further information , visit link below:-
                https://www.schneider-electric.com.au/en/search/A9N18365
                User-added image

                What is the replacement for 18354, 4P pole , B curve, 100A, 10KA circuit breaker?

                We do not have a direct replacement for 18354. We have A9N18436 which is rated to 15KA.  A9N18436 is 4P pole , B curve, 100A, 15KA circuit breaker.
                For further information, please visit https://www.schneider-electric.com/en/product/A9N18436/c120h---circuit-breaker---4p---100a---b-curve/

                 

                Is it okay to terminate aluminium cables to the Acti 9 MCB's?

                Aluminium is more corrosive than copper and it can cause high resistance to the current flow over the period of time, So it is highly recommend to use the 27060 aluminium connection terminal if you are using Aluminium cables. 

                What is the part number for the 80 amp 3 pole and neutral 30mA RCBO, 10kA?

                The RCBO is made up with the 4 pole iC120N circuit breaker, part number A9N18372 plus add the 4 pole Vigi unit A9N18578

                https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9N18372 

                and
                https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9N18578

                User-added image    User-added image
                 

                Where can I download documentation for the ION8300, ION8400 and ION8500 series meters?

                Issue:
                A user needs to download documentation for the ION8300, ION8400 and ION8500 series meters.
                 
                Product Line:
                ION8300, ION8400 and ION8500

                Environment:
                Installation Guide, User Guide, Datasheet, DNP3 Device Profile, I/O Expander Installation, Modbus Register Map, Retrofit Instructions
                 
                Cause:
                A user needs to download various documentation for the ION8300, ION8400 and ION8500.
                 
                Resolution:
                See the attached documents below.
                 

                Device Support - Updater for ION8500 V244 meters in ION Enterprise

                Issue
                Older versions of the ION Enterprise software either do not natively support the ION8500 device types or do not support all features available in the latest available firmware.

                Product Line
                ION Enterprise V5.0 
                ION Enterprise V5.5
                ION Enterprise V5.6 
                ION8500

                Environment
                Device Support Update

                Resolution
                To support new firmware features, download the ION Enterprise software updater below. These updater files are compatible with ION Enterprise and Pegasys. Remember that upgrader files must be applied to all machines in your ION Enterprise network, including all primary, secondary and client machines, for the upgrades to be effective.


                BACKGROUND INFORMATION

                What is the Updater program?
                When versions of ION Enterprise are released, they support Power Measurement meters only up to the date of release. In order for our software to correctly recognize new firmware versions on the meters, the Updater program was created. These files are designed to install the components necessary to support the new firmware releases for ION meters.

                ION8500 Meter Template Files

                Product Line
                ION8500

                Environment
                Templates

                Resolution
                You can install meter templates using ION Setup. See the "Upgrading ION Device Firmware" technical note for complete details.

                Install Templates with ION Setup

                1. Download the device template and save it to your ION Setup TEMPLATE folder (select the file below that matches your meter's feature set).

                Use these .DCF files with ION Setup to perform firmware upgrades. These are default meter templates only. If you have custom programming in your meter, create your own template file before performing the firmware upgrade.

                1. Follow the upgrade procedures outlined in the Upgrading ION Device Firmware technical note.
                See the .zip below for the following templates:
                Version Low Current (Class 2) Standard (Class 20) ECR (Class 2-20)
                V264-265 8500_FAC-9S-39S-36S-76S_V2.6.0.0.9
                8500_FAC-35S_V2.6.0.0.9
                   
                V262 8500_FAC-9S-39S-36S-76S_V2.6.0.0.2
                8500_FAC-9S-39S-36S-76S_V2.6.0.0.2
                   
                V244 8500_v240_FAC-9S-39S_V1.9.0.0.0
                8500_v240_FAC-35S_V1.9.0.0.0
                8500_v240_FAC-36S-76S_V1.9.0.0.0
                text8500_v240_FAC-C2A-9S-39S_V1.9.0.0.0
                8500_v240_FAC-C2A-35S_V1.9.0.0.0
                8500_v240_FAC-C2A-36S-76S_V1.9.0.0.0
                Show More