Item Number: A9MEM3565

Retail
$1,193.45
RRP (Inc. GST)

Product Dimensions

Width icon

Width90 mm

Height icon

Height87 mm

Depth icon

Depth69 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Acti 9

Product or component type

energy meter

Market segment

  • buildings small building cost management: billing: main incomer
  • buildings small building cost management: billing: sub feeder
  • buildings small building cost management: billing: panelboard
  • buildings medium building cost management: billing: main incomer
  • buildings medium building cost management: billing: sub feeder
  • buildings medium building cost management: billing: panelboard
  • buildings large building cost management: billing: main incomer
  • buildings large building cost management: billing: sub feeder
  • buildings large building cost management: billing: panelboard
  • buildings multi-site cost management: billing: main incomer
  • buildings multi-site cost management: billing: sub feeder
  • buildings multi-site cost management: billing: panelboard
  • datacenter cost management: billing
  • healthcare cost management: billing
  • industry cost management: billing
  • buildings small building cost management: cost allocation: main incomer
  • buildings small building cost management: cost allocation: sub feeder
  • buildings small building cost management: cost allocation: panelboard
  • buildings medium building cost management: cost allocation: main incomer
  • buildings medium building cost management: cost allocation: sub feeder
  • buildings medium building cost management: cost allocation: panelboard
  • buildings large building cost management: cost allocation: main incomer
  • buildings large building cost management: cost allocation: sub feeder
  • buildings large building cost management: cost allocation: panelboard
  • buildings multi-site cost management: cost allocation: main incomer
  • buildings multi-site cost management: cost allocation: sub feeder
  • buildings multi-site cost management: cost allocation: panelboard
  • datacenter cost management: cost allocation
  • healthcare cost management: cost allocation
  • industry cost management: cost allocation
    • Device application

    • sub billing
    • partial meter
    • multi-tariff
      • Physical

        Rated voltage

      • 100-277 V +/- 20 %
      • 173-480 V +/- 20 %
        • Communication port protocol

          BACnet at 9.6, 19.2, 38.4, 57.6, 76.8 kbauds

          Local signalling

        • green indicator light: power ON
        • yellow flashing LED: accuracy checking
        • alarm: overload
          • Mounting mode

            clip-on

            Mounting support

            DIN rail

            Connections - terminals

          • current circuit: screw terminals 6-6 mm² cable(s)
          • voltage circuit: screw terminals 2.5-2.5 mm² cable(s)
          • input/output circuit: screw terminals 1.5-1.5 mm² cable(s)
          • communication: screw terminals 2.5-2.5 mm² cable(s)
            • Wire stripping length

            • input/output circuit: 6 mm
            • voltage circuit: 8 mm
            • current circuit: 8 mm
            • communication: 7 mm
              • Standards

              • IEC 61557-12
              • IEC 61036
              • UL 61010-1
              • IEC 61010
              • IEC 62053-21
              • IEC 62053-23
                • Product certifications

                • CE conforming to IEC 61010 (safety)
                • CE conforming to EN 61557-12 (power monitor)
                • CE conforming to IEC 61326-1 (EMC)
                • cULus conforming to UL 61010 (safety)
                • cULus conforming to ANSI C12.20 (sub-meter)
                • EAC (sub-meter)
                • RCM conforming to NMI M 6-1 (sub-meter)
                • UL
                  • IP degree of protection

                  • IP40 front panel: conforming to IEC 60529
                  • IP20 body: conforming to IEC 60529
                    • IK degree of protection

                      IK08

                      Relative humidity

                      5-95 % at 36-36 °C

                      Ambient air temperature for operation

                      -25-70 °C - IEC

                      Ambient air temperature for storage

                      -40-85 °C

                      Width

                      90 mm

                      Height

                      87 mm

                      Depth

                      69 mm

                      REACh Regulation

                      Free of Substances of Very High Concern above the threshold

                      EU RoHS Directive

                      Compliant

                      Mercury free

                      Yes

                      RoHS exemption information

                      Yes

                      China RoHS Regulation

                      X

                      Others

                      Product name

                      Acti 9 iEM3000

                      Device short name

                      iEM3565

                      Poles description

                    • 1P + N
                    • 3P + N
                    • 3P
                      • Type of measurement

                      • active and reactive energy
                      • active and reactive power
                      • current
                      • voltage
                        • Metering type

                          active, reactive, apparent energy (signed, four quadrant)

                          Accuracy class

                        • class 0.5S active energy conforming to IEC 62053-22
                        • class 0.5S active energy conforming to ANSI C12.20
                          • Analogue input type

                            Rogowski coil 50...5000 A

                            Network frequency

                          • 50 Hz
                          • 60 Hz
                            • Technology type

                              electronic

                              Display type

                              LCD display

                              Sampling rate

                              32 samples/cycle

                              Measurement current

                              50-5000 A

                              Maximum value measured

                            • 99999999.9 kWh
                            • 99999999 MWh
                              • Information displayed

                                tariff (4)

                                Communication port support

                                screw terminal block: RS485

                                Number of inputs

                                1 digital 0...5 V/11...40 V 24 V DC

                                Number of outputs

                                1 digital (static)

                                Output voltage

                                5...40 V DC@50 mA

                                Tightening torque

                              • input/output circuit: 0.5-0.5 N.m Philips screwdriver
                              • voltage circuit: 0.5-0.5 N.m Philips screwdriver
                              • current circuit: 0.8-0.8 N.m pozidriv screwdriver
                              • communication: 0.5-0.5 N.m Philips screwdriver
                                • Compatibility code

                                  iEM3565

                                  Pollution degree

                                  2

                                  Operating altitude

                                  < 3000 m

                                  9 mm pitches

                                  10

                                  Package 1 Weight

                                  0.323 kg

                                  Package 1 Height

                                  0.88 dm

                                  Package 1 width

                                  0.98 dm

                                  Package 1 Length

                                  1.05 dm

                                  WEEE

                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                  Show all specifications

                                  Documents & downloads

                                  hide show
                                  Filter items
                                  • All

                                  • Product Brochures

                                  • Technical Data Catalogues

                                  • Technical Leaflet

                                  • End of Life Manual

                                  • Product Environmental

                                  • Installation Instruction

                                  • Operating Manuals

                                  • Certificates (MSDS)

                                  • Declaration of Conformity

                                  Frequently Asked Questions

                                  hide show

                                  What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                                  A9MEM3155 - 16mm
                                  A9MEM3355 - 50mm
                                  For further information , visit links below:-
                                  https://www.schneider-electric.com.au/en/search/A9MEM3155
                                  https://www.schneider-electric.com.au/en/search/A9MEM3355
                                  User-added image

                                  Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                                  The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                                   

                                  Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                                  We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                                   

                                  Is the Acti 9 A9MEM3110 3 phase?

                                  Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                                  What is the alternate part number for 17072

                                   Replacement is a A9MEM3210

                                  Which KWH meter will measure Solar inputs with Modbus connections?

                                  Show More