Specifications

hide show
Range
Acti 9
Product name
Acti 9 iEM3000
Device short name
iEM3565
Product or component type
energy meter
Market segment
  • buildings small building cost management: billing: main incomer
  • buildings small building cost management: billing: sub feeder
  • buildings small building cost management: billing: panelboard
  • buildings medium building cost management: billing: main incomer
  • buildings medium building cost management: billing: sub feeder
  • buildings medium building cost management: billing: panelboard
  • buildings large building cost management: billing: main incomer
  • buildings large building cost management: billing: sub feeder
  • buildings large building cost management: billing: panelboard
  • buildings multi-site cost management: billing: main incomer
  • buildings multi-site cost management: billing: sub feeder
  • buildings multi-site cost management: billing: panelboard
  • datacenter cost management: billing
  • healthcare cost management: billing
  • industry cost management: billing
  • buildings small building cost management: cost allocation: main incomer
  • buildings small building cost management: cost allocation: sub feeder
  • buildings small building cost management: cost allocation: panelboard
  • buildings medium building cost management: cost allocation: main incomer
  • buildings medium building cost management: cost allocation: sub feeder
  • buildings medium building cost management: cost allocation: panelboard
  • buildings large building cost management: cost allocation: main incomer
  • buildings large building cost management: cost allocation: sub feeder
  • buildings large building cost management: cost allocation: panelboard
  • buildings multi-site cost management: cost allocation: main incomer
  • buildings multi-site cost management: cost allocation: sub feeder
  • buildings multi-site cost management: cost allocation: panelboard
  • datacenter cost management: cost allocation
  • healthcare cost management: cost allocation
  • industry cost management: cost allocation
    • Poles description
    • 1P + N
    • 3P + N
    • 3P
      • Type of measurement
      • active and reactive energy
      • active and reactive power
      • current
      • voltage
        • Metering type
          active, reactive, apparent energy (signed, four quadrant)
          Device application
        • sub billing
        • partial meter
        • multi-tariff
          • Accuracy class
          • class 0.5S active energy conforming to IEC 62053-22
          • class 0.5S active energy conforming to ANSI C12.20
            • Analogue input type
              Rogowski coil 50...5000 A
              Rated voltage
            • 100-277 V +/- 20 %
            • 173-480 V +/- 20 %
              • Network frequency
              • 50 Hz
              • 60 Hz
                • Technology type
                  electronic
                  Display type
                  LCD display
                  Sampling rate
                  32 samples/cycle
                  Measurement current
                  50-5000 A
                  Maximum value measured
                • 99999999.9 kWh
                • 99999999 MWh
                  • Information displayed
                    tariff (4)
                    Communication port protocol
                    BACnet at 9.6, 19.2, 38.4, 57.6, 76.8 kbauds
                    Communication port support
                    screw terminal block: RS485
                    Local signalling
                  • green indicator light: power ON
                  • yellow flashing LED: accuracy checking
                  • alarm: overload
                    • Number of inputs
                      1 digital 0...5 V/11...40 V 24 V DC
                      Number of outputs
                      1 digital (static)
                      Output voltage
                      5...40 V DC@50 mA
                      Mounting mode
                      clip-on
                      Mounting support
                      DIN rail
                      Connections - terminals
                    • current circuit: screw terminals 6-6 mm² cable(s)
                    • voltage circuit: screw terminals 2.5-2.5 mm² cable(s)
                    • input/output circuit: screw terminals 1.5-1.5 mm² cable(s)
                    • communication: screw terminals 2.5-2.5 mm² cable(s)
                      • Tightening torque
                      • input/output circuit: 0.5-0.5 N.m Philips screwdriver
                      • voltage circuit: 0.5-0.5 N.m Philips screwdriver
                      • current circuit: 0.8-0.8 N.m pozidriv screwdriver
                      • communication: 0.5-0.5 N.m Philips screwdriver
                        • Wire stripping length
                        • input/output circuit: 6 mm
                        • voltage circuit: 8 mm
                        • current circuit: 8 mm
                        • communication: 7 mm
                          • Standards
                          • IEC 61557-12
                          • IEC 61036
                          • UL 61010-1
                          • IEC 61010
                          • IEC 62053-21
                          • IEC 62053-23
                            • Product certifications
                            • CE conforming to IEC 61010 (safety)
                            • CE conforming to EN 61557-12 (power monitor)
                            • CE conforming to IEC 61326-1 (EMC)
                            • cULus conforming to UL 61010 (safety)
                            • cULus conforming to ANSI C12.20 (sub-meter)
                            • EAC (sub-meter)
                            • RCM conforming to NMI M 6-1 (sub-meter)
                            • UL
                              • Compatibility code
                                iEM3565
                                IP degree of protection
                              • IP40 front panel: conforming to IEC 60529
                              • IP20 body: conforming to IEC 60529
                                • IK degree of protection
                                  IK08
                                  Pollution degree
                                  2
                                  Relative humidity
                                  5-95 % at 36-36 °C
                                  Ambient air temperature for operation
                                  -25-70 °C - IEC
                                  Ambient air temperature for storage
                                  -40-85 °C
                                  Operating altitude
                                  < 3000 m
                                  9 mm pitches
                                  10
                                  Width
                                  90 mm
                                  Height
                                  87 mm
                                  Depth
                                  69 mm
                                  Package 1 Weight
                                  0.323 kg
                                  Package 1 Height
                                  0.88 dm
                                  Package 1 width
                                  0.98 dm
                                  Package 1 Length
                                  1.05 dm
                                  EU RoHS Directive
                                  Compliant
                                  Mercury free
                                  Yes
                                  RoHS exemption information
                                  Yes
                                  China RoHS Regulation
                                  X
                                  WEEE
                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                  Documents & downloads

                                  hide show
                                  Filter items
                                  • All

                                  • Product Brochures

                                  • Technical Data Catalogues

                                  • Technical Leaflet

                                  • Product Environmental

                                  • End of Life Manual

                                  • Installation Instruction

                                  • Operating Manuals

                                  • Certificates (MSDS)

                                  • Declaration of Conformity

                                  Frequently Asked Questions

                                  hide show

                                  What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                                  A9MEM3155 - 16mm
                                  A9MEM3355 - 50mm
                                  For further information , visit links below:-
                                  https://www.schneider-electric.com.au/en/search/A9MEM3155
                                  https://www.schneider-electric.com.au/en/search/A9MEM3355
                                  User-added image

                                  Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                                  The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                                   

                                  Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                                  We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                                   

                                  Is the Acti 9 A9MEM3110 3 phase?

                                  Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                                  What is the alternate part number for 17072

                                   Replacement is a A9MEM3210

                                  Which KWH meter will measure Solar inputs with Modbus connections?

                                  What is the alternative code for 17072?

                                  A9MEM3210

                                  On the PowerTag A9 F63 model, ref. A9MEM1562 if I try to be consistent with the flat cable position, the LED of the module is upwards. Should I twist the flat cable to have the LED down?

                                  This has no impact on the operation but to be consistent with the rest of the range we favor the Led down, and in this case, the flat cable is twisted.

                                  Can the IEM3000 series read energy output from a Solar Panel?

                                  To be able to measure the energy out from a Solar Panel a meter needs to be able to do Four Quadrant Calculation.

                                  This means it is capable of Identification of imported and exported active and reactive energy allows you to monitor energy flow in both directions: delivered from the utility and produced on-site.

                                  In the iEM3000 series the following meters are capable of Four Quadrant Calculation.

                                  iEM31** range - iEM3135, iEM3155, iEM3165, and iEM3175
                                  iEM32** range - iEM3235, iEM3255, iEM3265, and iEM3275
                                  iEM33** range - iEM3335, iEM3355, iEM3365, and iEM3375
                                  iEM34** range - iEM3455, iEM3465, iEM3555, and iEM3565


                                   

                                  What is the replacement for 15467 Power meter with 100/5 CTs?

                                  What is the part number for Single phase KWH meter?

                                  The part number for Single phase KWH meter will be a - A9MEM2105.
                                  Please refer the below link for more information,
                                  https://www.schneider-electric.com/en/product/A9MEM2105/modular-single-phase-power-meter-iem2105---230v---63a-with-pulse/
                                  Image result for a9mem2105 schneider



                                   

                                  Can Rogowski Coil Current Transformers (Rope Style CT's) Be Extended in the Field? How Far?

                                  Issue
                                  Rogowski Coil CT's may require secondary lead length extension.

                                  Product Line
                                  A9MEM3500 meters
                                  EM4200 meters
                                  EM3500 meters
                                  U018 Rogowski Coil Current Transformers

                                  Environment
                                  Metering & Power Monitoring

                                  Cause
                                  The load may be farther from the meter than the standard 8' or 12' secondary lead lengths may reach.

                                  Resolution
                                  Schneider Rogowski Coil Current Transformers come in primary lengths of 12", 18", 24", or 36". 
                                  This measurement only applies to the primary length only.
                                  This is the length that the current transformer has to connect back to itself around a conductor or set of conductors of the load to be monitored.

                                  The lead length refers to the 8' or 12' that connects from the current transformer to the meter itself.

                                  It is sometimes difficult to get the meter mounting location within 8' or 12' from an appropriate location to install the current transformer on the load conductors.
                                  Because of this, one may need to extend the length of the secondary leads from the current transformers.

                                  Either the 8' or the 12' secondary lead length version of Schneider's Rogowski Coil (U018-xxx) Current Transformers may be extended to a maximum of 20' total lead length (to include the original lead length of either 8' or 12').
                                  The conductors used must be a standard 24 gauge twisted cable.
                                  Show More