Quantcast

Din-Rail kWh Meter (125A Direct Connect, Modbus Rtu)

Din-Rail kWh Meter (125A Direct Connect, Modbus Rtu)

Din-Rail kWh Meter (125A Direct Connect, Modbus Rtu)

Item Number: A9MEM3350-NMI

Retail
N/A
RRP (Inc. GST)

Product Dimensions

Width icon

Width126 mm

Height icon

Height103.2 mm

Depth icon

Depth69.3 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Acti 9

Product or component type

energy meter

Market segment

  • buildings small building cost management: billing: main incomer
  • buildings small building cost management: billing: sub feeder
  • buildings small building cost management: billing: panelboard
  • buildings medium building cost management: billing: main incomer
  • buildings medium building cost management: billing: sub feeder
  • buildings medium building cost management: billing: panelboard
  • buildings large building cost management: billing: main incomer
  • buildings large building cost management: billing: sub feeder
  • buildings large building cost management: billing: panelboard
  • buildings multi-site cost management: billing: main incomer
  • buildings multi-site cost management: billing: sub feeder
  • buildings multi-site cost management: billing: panelboard
  • data center cost management: billing
  • healthcare cost management: billing
  • industry cost management: billing
  • buildings small building cost management: cost allocation: main incomer
  • buildings small building cost management: cost allocation: sub feeder
  • buildings small building cost management: cost allocation: panelboard
  • buildings medium building cost management: cost allocation: main incomer
  • buildings medium building cost management: cost allocation: sub feeder
  • buildings medium building cost management: cost allocation: panelboard
  • buildings large building cost management: cost allocation: main incomer
  • buildings large building cost management: cost allocation: sub feeder
  • buildings large building cost management: cost allocation: panelboard
  • buildings multi-site cost management: cost allocation: main incomer
  • buildings multi-site cost management: cost allocation: sub feeder
  • buildings multi-site cost management: cost allocation: panelboard
  • data center cost management: cost allocation
  • healthcare cost management: cost allocation
  • industry cost management: cost allocation
    • Device application

    • partial meter
    • sub billing
      • Physical

        [In] rated current

        125 A

        Rated voltage

      • 100-277 V
      • 173-480 V
        • Communication port protocol

          Modbus RTU at 9.6, 19.2 and 38.4 kbauds even/odd or none, insulation 4000 V

          Local signalling

        • green indicator light: power ON
        • yellow flashing LED: accuracy checking
        • yellow indicator light: communications are active on the Modbus port (Modbus)
          • Mounting mode

            clip-on

            Mounting support

            DIN rail

            Connections - terminals

            screw terminals 50-50 mm² cable(s)

            Standards

          • IEC 61010
          • IEC 61036
          • IEC 62053-21
          • IEC 62053-23
          • IEC 61557-12
            • Product certifications

            • CE conforming to IEC 61010 (safety)
            • CE conforming to EN 61557-12 (power monitor)
            • CE conforming to IEC 61326-1 (EMC)
            • cULus conforming to UL 61010 (safety)
            • cULus conforming to ANSI C12.20 (sub-meter)
            • EAC (sub-meter)
            • RCM
            • ACMA
            • NMI conforming to NMI M 6-1 (sub-meter)
              • IP degree of protection

              • IP40 front panel: conforming to IEC 60529
              • IP20 body: conforming to IEC 60529
                • Relative humidity

                  5-95 % at 50-50 °C

                  Ambient air temperature for operation

                  -25-60 °C - IEC

                  Ambient air temperature for storage

                  -40-85 °C

                  Width

                  126 mm

                  Height

                  103.2 mm

                  Depth

                  69.3 mm

                  Others

                  Product name

                  Acti 9 iEM3000

                  Device short name

                  iEM3350

                  Poles description

                • 3P + N
                • 3P
                • 1P + N
                  • Type of measurement

                  • active energy
                  • current
                  • voltage
                  • active power
                    • Accuracy class

                    • class 1 active energy conforming to IEC 62053-21
                    • class 1 active energy conforming to IEC 61557-12
                    • class B active energy conforming to EN 50470-3
                      • Analogue input type

                        direct input

                        Network frequency

                      • 50 Hz
                      • 60 Hz
                        • Technology type

                          electronic

                          Display type

                          LCD display

                          Sampling rate

                          32 samples/cycle

                          Measurement current

                          0-125 A

                          Maximum value measured

                          99999999.9 kWh

                          Communication port support

                          screw terminal block: RS485

                          Number of inputs

                          0

                          Number of outputs

                          0

                          Overvoltage category

                          III

                          Pollution degree

                          2

                          Operating altitude

                          < 2000 m

                          9 mm pitches

                          14

                          Unit Type of Package 1

                          PCE

                          Number of Units in Package 1

                          1

                          Package 1 Weight

                          704 g

                          Package 1 Height

                          86 mm

                          Package 1 width

                          120 mm

                          Package 1 Length

                          130 mm
                          Show all specifications

                          Documents & downloads

                          hide show
                          Filter items
                          • All

                          • Product Brochures

                          Frequently Asked Questions

                          hide show

                          Which are the NMI approved meters?

                          Following are the NMI approved metres:

                          iem3255,....part number A9MEM3255-NMI.........https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9MEM3255
                          iem3350.....part number A9MEM3350-NMI
                          em1350......part number METSEEPM3150

                          iEM3255       iEM3255                EM1350EM1350
                           

                          What are the part numbers for the NMI approved KWH Meters?

                          Following are the part numbers for the National Measurement Institute NMI M6-1 Pattern Approved- Kilowatt Hour Meters-1P/3P/3P+N - LCD Digital

                          Model                                                                                                                                Reference
                          IEM3255 DIN-rail kWh meter - 5A or 1A external CTs, Modbus RS485, DI / DO ---------    A9MEM3255-NMI
                          IEM3350 DIN-rail kWh meter - 125A direct connect, Modbus RS485 ----------                   A9MEM3350-NMI

                          Features:
                          • Meter verification report available upon request.
                          • Meters verified in accordance to National Measurement Institute NITP-14


                          For more informaion and meters please check the following link:
                          https://download.schneider-electric.com/files?p_enDocType=Catalog&p_File_Name=PLSED309005EN_Web.pdf&p_Doc_Ref=PLSED309005EN_Web