Triphase kWh meter CT pulse MID - iEM3210

Acti 9 Triphase Kwh iEM3210 Energy Meter, CT, 1 Pulse O

Catalogue Number: A9MEM3210
Triphase kWh meter CT pulse MID - iEM3210
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Acti 9
Product name
Acti 9 iEM3000
Device short name
iEM3210
Product or component type
energy meter
Market segment
Poles description
  • 3P
  • 1P + N
  • 3P + N
    • Type of measurement
      active energy
      Device application
    • partial meter
    • sub billing
      • Accuracy class
      • class 0.5S active energy conforming to IEC 62053-22
      • class 0.5S active energy conforming to IEC 61557-12
      • class C active energy conforming to EN 50470-3
        • Analogue input type
          external CT 1 A or 5 A
          [In] rated current
        • 5 A
        • 1 A
          • Rated voltage
          • 100-277 V
          • 173-480 V
            • Network frequency
            • 50 Hz
            • 60 Hz
              • Technology type
                electronic
                Display type
                LCD display
                Sampling rate
                32 samples/cycle
                Measurement current
                1-32767000 mA
                Maximum value measured
                99999999 MWh
                Communication port protocol
                -
                Communication port support
                -
                Local signalling
              • green indicator light: power ON
              • yellow flashing LED: accuracy checking
                • Number of inputs
                  0
                  Number of outputs
                  1 pulse
                  Mounting mode
                  clip-on
                  Mounting support
                  DIN rail
                  Connections - terminals
                • current circuit: screw terminals 6-6 mm² cable(s)
                • voltage circuit: screw terminals 2.5-2.5 mm² cable(s)
                  • Overvoltage category
                    III
                    Standards
                  • IEC 61036
                  • UL 61010-1
                  • IEC 61557-12
                  • IEC 62053-22
                  • IEC 61010
                  • IEC 62053-23
                    • Product certifications
                    • CE conforming to IEC 61010 (safety)
                    • CE conforming to EN 61557-12 (power monitor)
                    • CE conforming to IEC 61326-1 (EMC)
                    • cULus conforming to UL 61010 (safety)
                    • cULus conforming to ANSI C12.20 (sub-meter)
                    • EAC (sub-meter)
                    • RCM conforming to NMI M 6-1 (sub-meter)
                    • UL
                    • MID conforming to EN 50470-3 (sub-meter)
                    • MID conforming to EN 62052 (sub-meter)
                      • Market segment
                      • residential
                      • small commercial
                        • Compatibility code
                          iEM3210
                          IP degree of protection
                        • IP40 front panel: conforming to IEC 60529
                        • IP20 body: conforming to IEC 60529
                          • Pollution degree
                            2
                            Relative humidity
                            5-95 % at 50-50 °C
                            Ambient air temperature for operation
                          • -25-55 °C - MID
                          • -25-60 °C - NMI
                          • -25-60 °C - IEC
                            • Ambient air temperature for storage
                              -40-85 °C
                              Operating altitude
                              < 2000 m
                              9 mm pitches
                              10
                              Width
                              90 mm
                              Height
                              95 mm
                              Depth
                              69 mm
                              Sustainable offer status
                              Green Premium product
                              EU RoHS Directive
                              Compliant
                              Mercury free
                              Yes
                              RoHS exemption information
                              Yes
                              China RoHS Regulation
                              X
                              Environmental Disclosure
                              ENVPEP111276EN
                              Circularity Profile
                              ENVEOLI111261EN_V1
                              WEEE
                              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                              California proposition 65
                              WARNING: This product can expose you to chemicals including: Carbon-black extracts and Bisphenol A (BPA) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
                              Warranty
                              18 months

                              Documents & downloads

                              hide show
                              Filter items
                              • All

                              • CAD Files and Packs

                              • Product Brochures

                              • Movies

                              • Technical Data Catalogues

                              • Catalog Page

                              • Technical Leaflet

                              • End of Life Manual

                              • Product Environmental

                              • Installation Instruction

                              • Handout

                              • Data Bulletin

                              • Operating Manuals

                              • Specifications

                              • Specification for Tender

                              • Application Solutions

                              • Case Studies

                              • Certificates (MSDS)

                              • White Paper

                              • Declaration of Conformity

                              • Software - Released

                              • Firmware - Updates

                              • Software - Updates

                              • Software - Demos & Trial

                              Frequently Asked Questions

                              hide show

                              What is the alternate part number for 17072

                               Replacement is a A9MEM3210

                              What is the replacement for a 17072

                               The replacement is a A9MEM3210.

                              What is the alternative code for 17072?

                              A9MEM3210

                              Is the Acti 9 A9MEM3110 3 phase?

                              Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                              What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                              A9MEM3155 - 16mm
                              A9MEM3355 - 50mm
                              For further information , visit links below:-
                              https://www.schneider-electric.com.au/en/search/A9MEM3155
                              https://www.schneider-electric.com.au/en/search/A9MEM3355
                              User-added image

                              What is the replacement for 15467 Power meter with 100/5 CTs?

                              What are the power terminal sizes on the A9MEM3100?

                              The power terminal sizes of the iEM3100 meter will take 16mm cable
                              see instruction sheet....https://eshop.schneider-electric.com/Download.aspx?infos=H808089_1.pdf;3

                              ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                              The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                              Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                              The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                               

                              What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

                              The product code is A9MEM2000. Please see the attached datasheet for more information.
                               

                              Which KWH meter will measure Solar inputs with Modbus connections?

                              What is the part number for Single phase KWH meter?

                              The part number for Single phase KWH meter will be a - A9MEM2105.
                              Please refer the below link for more information,
                              https://www.schneider-electric.com/en/product/A9MEM2105/modular-single-phase-power-meter-iem2105---230v---63a-with-pulse/
                              Image result for a9mem2105 schneider



                               

                              Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                              We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                               

                              Can the IEM3000 series read energy output from a Solar Panel?

                              To be able to measure the energy out from a Solar Panel a meter needs to be able to do Four Quadrant Calculation.

                              This means it is capable of Identification of imported and exported active and reactive energy allows you to monitor energy flow in both directions: delivered from the utility and produced on-site.

                              In the iEM3000 series the following meters are capable of Four Quadrant Calculation.

                              iEM31** range - iEM3135, iEM3155, iEM3165, and iEM3175
                              iEM32** range - iEM3235, iEM3255, iEM3265, and iEM3275
                              iEM33** range - iEM3335, iEM3355, iEM3365, and iEM3375
                              iEM34** range - iEM3455, iEM3465, iEM3555, and iEM3565


                               

                              Can Rogowski Coil Current Transformers (Rope Style CT's) Be Extended in the Field? How Far?

                              Issue
                              Rogowski Coil CT's may require secondary lead length extension.

                              Product Line
                              A9MEM3500 meters
                              EM4200 meters
                              EM3500 meters
                              U018 Rogowski Coil Current Transformers

                              Environment
                              Metering & Power Monitoring

                              Cause
                              The load may be farther from the meter than the standard 8' or 12' secondary lead lengths may reach.

                              Resolution
                              Schneider Rogowski Coil Current Transformers come in primary lengths of 12", 18", 24", or 36". 
                              This measurement only applies to the primary length only.
                              This is the length that the current transformer has to connect back to itself around a conductor or set of conductors of the load to be monitored.

                              The lead length refers to the 8' or 12' that connects from the current transformer to the meter itself.

                              It is sometimes difficult to get the meter mounting location within 8' or 12' from an appropriate location to install the current transformer on the load conductors.
                              Because of this, one may need to extend the length of the secondary leads from the current transformers.

                              Either the 8' or the 12' secondary lead length version of Schneider's Rogowski Coil (U018-xxx) Current Transformers may be extended to a maximum of 20' total lead length (to include the original lead length of either 8' or 12').
                              The conductors used must be a standard 24 gauge twisted cable.

                              Power Meter Communication issue, registers not reading the correct value.

                              The Power meters, based on the manufacturing location may have an offset. 

                              In some meters the registers starts from Zero and some it is taken account from 1. So the published register list varies accordingly. 

                              For Ex: If Register 2017 is for Frequency of the meters it will read 50 HZ. 
                              But for the meter with offset the the Register 2016 will read 50HZ. 

                              So it is good to check if the meter has got an Offset before proceeding with the communication issue. 

                              What are the Dimensions for the A9MEM2000 single phase power meter?

                                9 mm pitches 2  
                               
                               
                                Width 18 mm  
                               
                               
                                Height 95 mm  
                               
                               
                                Depth 67 mm  
                               
                               
                                Product weight 0.073 kg  

                              On the PowerTag A9 F63 model, ref. A9MEM1562 if I try to be consistent with the flat cable position, the LED of the module is upwards. Should I twist the flat cable to have the LED down?

                              This has no impact on the operation but to be consistent with the rest of the range we favor the Led down, and in this case, the flat cable is twisted.