Specifications

Design

Range

Acti9

Product or component type

energy meter

Market segment

  • buildings small building cost management: billing: main incomer
  • buildings small building cost management: billing: sub feeder
  • buildings small building cost management: billing: panelboard
  • buildings medium building cost management: billing: main incomer
  • buildings medium building cost management: billing: sub feeder
  • buildings medium building cost management: billing: panelboard
  • buildings large building cost management: billing: main incomer
  • buildings large building cost management: billing: sub feeder
  • buildings large building cost management: billing: panelboard
  • buildings multi-site cost management: billing: main incomer
  • buildings multi-site cost management: billing: sub feeder
  • buildings multi-site cost management: billing: panelboard
  • data center cost management: billing
  • healthcare cost management: billing
  • industry cost management: billing
  • buildings small building cost management: cost allocation: main incomer
  • buildings small building cost management: cost allocation: sub feeder
  • buildings small building cost management: cost allocation: panelboard
  • buildings medium building cost management: cost allocation: main incomer
  • buildings medium building cost management: cost allocation: sub feeder
  • buildings medium building cost management: cost allocation: panelboard
  • buildings large building cost management: cost allocation: main incomer
  • buildings large building cost management: cost allocation: sub feeder
  • buildings large building cost management: cost allocation: panelboard
  • buildings multi-site cost management: cost allocation: main incomer
  • buildings multi-site cost management: cost allocation: sub feeder
  • buildings multi-site cost management: cost allocation: panelboard
  • data center cost management: cost allocation
  • healthcare cost management: cost allocation
  • industry cost management: cost allocation

Device application

  • multi-tariff
  • sub billing
  • partial meter

Market segment

  • small commercial
  • residential

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[In] rated current

63 A

Rated voltage

  • 100...277 V
  • 173...480 V

Communication port protocol

Modbus RTU at 9.6, 19.2 and 38.4 kbauds even/odd or none, insulation 4000 V

Local signalling

  • green indicator light: power ON
  • yellow flashing LED: accuracy checking
  • alarm: overload
  • yellow indicator light: communications are active on the Modbus port (Modbus)

Mounting mode

clip-on

Mounting support

DIN rail

Connections - terminals

screw terminals 16-16 mm² cable(s)

Standards

  • BS EN 61557-12
  • IEC 61557-12
  • EN 61557-12
  • BS EN 61326-1
  • IEC 61326-1
  • EN 61326-1
  • BS EN 62052-11
  • IEC 62052-11
  • EN 62052-11
  • BS EN 62053-21
  • IEC 62053-21
  • EN 62053-21
  • BS EN 62052-23
  • IEC 62053-23
  • EN 62052-23
  • BS EN 62052-31
  • IEC 62052-31
  • EN 62052-31
  • BS EN 61010-1
  • EN 61010-1
  • IEC 61010-1
  • UL 61010-1
  • BS EN 61010-2-30
  • IEC 61010-2-30
  • EN 61010-2-30
  • UL 61010-2-30
  • BS EN 50470-3
  • EN 50470-3
  • BS EN 50470-1
  • EN 50470-1
  • ANSI C12.16

Product certifications

  • CE conforming to IEC 61010-1 (safety)
  • CE conforming to EN 61557-12 (power monitor)
  • CE conforming to EN/IEC 61326-1 (EMC)
  • UKCA conforming to BS EN 61010-1 (safety)
  • UKCA conforming to BS EN 61557-12 (power monitor)
  • UKCA conforming to BS EN 61326-1 (EMC)
  • cULus conforming to UL 61010-1 (safety)
  • cULus conforming to EN 61010-1 (safety)
  • EAC conforming to EN 50470-3 (sub-meter)
  • RCM conforming to EN 62052 (sub-meter)
  • KZ conforming to EN 50470-3 (sub-meter)
  • METAS conforming to EN 50470-1 (sub-meter)
  • MID conforming to EN 50470-3 (sub-meter)
  • MID conforming to EN 50470-1 (sub-meter)
  • NMI conforming to NMI M 6-1

IP degree of protection

  • IP40 front panel: conforming to IEC 60529
  • IP20 body: conforming to IEC 60529

Relative humidity

5...95 % at 50 °C

Ambient air temperature for operation

  • -25...55 °C - MID
  • -25...60 °C - NMI
  • -25...60 °C - IEC

Ambient air temperature for storage

-40...85 °C

Width

90 mm

Height

95 mm

Depth

69 mm

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

X

Environmental Disclosure

ENVPEP111276EN

Circularity Profile

ENVEOLI111261EN_V1

California proposition 65

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Others

Package 1 Bare Product Quantity

1

Product name

Acti9 iEM3000

Device short name

iEM3155

Poles description

  • 3P + N
  • 1P + N
  • 3P

Type of measurement

  • active and reactive energy
  • active and reactive power
  • current
  • voltage

Metering type

active, reactive, apparent energy (signed, four quadrant)

Accuracy class

  • class 1 active energy conforming to IEC 62053-21
  • class 1 active energy conforming to IEC 61557-12
  • class B active energy conforming to EN 50470-3

Analogue input type

direct input

Network frequency

  • 60 Hz
  • 50 Hz

Technology type

electronic

Display type

LCD display

Sampling rate

32 samples/cycle

Measurement current

0...63 A

Maximum value measured

99999999.9 kWh

Information displayed

tariff (4)

Communication port support

screw terminal block: RS485

Number of inputs

1 digital 0...5 V/11...40 V 24 V DC

Number of outputs

1 digital (static)

Output voltage

5...40 V DC@50 mA

Overvoltage category

III

Compatibility code

iEM3155

Pollution degree

2

Operating altitude

< 2000="">

9 mm pitches

10

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

8 cm

Package 1 Width

9.02 cm

Package 1 Length

10.01 cm

Package 1 Weight

0.46 kg

Unit Type of Package 2

S03

Number of Units in Package 2

30

Package 2 Height

30 cm

Package 2 Width

30 cm

Package 2 Length

40 cm

Package 2 Weight

14.306 kg

Unit Type of Package 3

P12

Number of Units in Package 3

720

Package 3 Height

80 cm

Package 3 Width

120 cm

Package 3 Length

110 cm

Package 3 Weight

352.344 kg

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Operating Manuals

  • Technical illustration

  • Declaration of Conformity

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Does iEM3000 Series Meter have internal battery?

There are two types of clock behaviours found on iEM3000 meter series.
iEM3110, iEM3210, iEM3150, iEM3250, iEM3310 and iEM3350
These meters lose the clock immediately after the power interruption as there is no super capacitor or battery built-in. When power is interrupted, the date and time are reset and you must enter configuration mode to configure the clock, if you require time information.

iEM3115, iEM3135, iEM3155, iEM3165, iEM3175, iEM3215, iEM3235, iEM3455/iEM3555, iEM3465/iEM3565, iEM3275, iEM3335, iEM3355, iEM3365, iEM3375, iEM3455, iEM3465, iEM3555 and iEM3565
These meters could  keep the clock running for up to 3 days in absence of external power, the meter design uses a built-in super capacitor (not a battery) to power the clock only and keep it running. If power is interrupted for longer than 3 days, the device automatically displays the screen to set Date and Time when power is restored.

Refer to User manual for further information (page 28).
https://www.se.com/ww/en/download/document/DOCA0005EN/

Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.