iEM2000 Series iEM2150 Product Image

iEM2000 Series Modular Single Phase Power Meter, 230V, 63A, Comm Modbus

Catalogue Number: A9MEM2150
iEM2000 Series iEM2150 Product Image
Retail
$747.75
RRP (Inc. GST)

Specifications

hide show
Range
Acti 9
Product name
Acti 9 iEM2100
Device short name
iEM2150
Product or component type
energy meter
Market segment
  • buildings small building cost management: billing: panelboard
  • buildings medium building cost management: billing: panelboard
  • buildings large building cost management: billing: panelboard
  • buildings multi-site cost management: billing: panelboard
  • datacenter cost management: billing: panelboard
  • healthcare cost management: billing: panelboard
  • industry cost management: billing: panelboard
  • buildings small building cost management: cost allocation: panelboard
  • buildings medium building cost management: cost allocation: panelboard
  • buildings large building cost management: cost allocation: panelboard
  • buildings multi-site cost management: cost allocation: panelboard
  • datacenter cost management: cost allocation: panelboard
  • healthcare cost management: cost allocation: panelboard
  • industry cost management: cost allocation: panelboard
    • Poles description
      1P + N
      Type of measurement
    • active and reactive energy
    • active and reactive power
    • current
    • voltage
      • Metering type
        active, reactive, apparent energy (signed, four quadrant)
        Device application
      • sub billing
      • partial meter
        • Accuracy class
        • class 1 active energy conforming to IEC 62053-21
        • class 2 reactive energy conforming to IEC 62053-23
          • Analogue input type
            direct input
            [In] rated current
            63 A
            Rated voltage
            230-230 V +/- 20 %
            Network frequency
          • 50 Hz
          • 60 Hz
            • Frequency measurement range
              45-65 Hz
              Technology type
              electronic
              Display type
              LCD display
              Sampling rate
              32 samples/cycle
              Measurement current
              0-63 A
              Display digits
              8
              Maximum value measured
              999999.99 kWh
              Information displayed
              tariff (1)
              Communication port protocol
              Modbus RTU at 1.2, 2.4, 4.8, 9.6, 19.2 and 38.4 kbauds even/odd or none - 3 wires, insulation 4000 V
              Communication port support
              screw terminals: RS485
              Local signalling
              red LED: accuracy checking 1...1000 p/kWh
              Number of inputs
              0-0
              Number of outputs
              0
              [Us] rated supply voltage
              96...276 V AC 50 Hz
              Maximum power consumption in VA
              2 VA
              Maximum power consumption in W
              1 W
              [Uimp] rated impulse withstand voltage
              6 kV 1.2/50 µs
              Mounting mode
              clip-on
              Mounting support
              DIN rail
              Connections - terminals
            • power circuit: tunnel type terminals (bottom) 1 1.65-33 mm² cable(s) solid
            • power circuit: tunnel type terminals (bottom) 1 1.65-33 mm² cable(s) stranded with cable end
            • communication: screw clamp terminals (top) 1 1-4 mm² cable(s) solid
            • communication: screw clamp terminals (top) 1 1-2.5 mm² cable(s) stranded with cable end
              • Tightening torque
              • power circuit: 2-2 N.m PZ2 screwdriver
              • communication: 0.5-0.5 N.m3.5 mm
                • Wire stripping length
                • power circuit: 17 mm
                • communication: 7 mm
                  • Standards
                  • IEC 62052-31
                  • IEC 62053-21
                  • IEC 62053-23
                  • IEC 62052-11
                    • Product certifications
                      CE
                      Compatibility code
                      iEM2150
                      IP degree of protection
                      IP20 conforming to IEC 60529
                      Overvoltage category
                      III
                      Pollution degree
                      2
                      Flame retardance
                      V0 conforming to UL 94
                      Ambient air temperature for operation
                      -25-55 °C
                      Ambient air temperature for storage
                      -25-70 °C
                      Relative humidity
                      0-95 %
                      9 mm pitches
                      4
                      Width
                      36 mm
                      Height
                      90 mm
                      Depth
                      64 mm
                      Net weight
                      0.175 kg
                      Unit Type of Package 1
                      PCE
                      Number of Units in Package 1
                      1
                      Package 1 Weight
                      220 g
                      Package 1 Height
                      5.2 cm
                      Package 1 width
                      8 cm
                      Package 1 Length
                      9.8 cm
                      Unit Type of Package 2
                      S02
                      Number of Units in Package 2
                      29
                      Package 2 Weight
                      6.835 kg
                      Package 2 Height
                      15 cm
                      Package 2 width
                      30 cm
                      Package 2 Length
                      40 cm
                      EU RoHS Directive
                      Compliant
                      Mercury free
                      Yes
                      RoHS exemption information
                      Yes
                      China RoHS Regulation
                      X

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • Product Brochures

                      • Technical Data Catalogues

                      • Technical Leaflet

                      • Installation Instruction

                      • Operating Manuals

                      • Declaration of Conformity

                      Frequently Asked Questions

                      hide show

                      What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                      A9MEM3155 - 16mm
                      A9MEM3355 - 50mm
                      For further information , visit links below:-
                      https://www.schneider-electric.com.au/en/search/A9MEM3155
                      https://www.schneider-electric.com.au/en/search/A9MEM3355
                      User-added image

                      What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

                      The product code is A9MEM2000. Please see the attached datasheet for more information.
                       

                      ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                      The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                      Is the Acti 9 A9MEM3110 3 phase?

                      Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                      What is the alternate part number for 17072

                       Replacement is a A9MEM3210

                      What is the alternative code for 17072?

                      A9MEM3210

                      What is the replacement for a 17072

                       The replacement is a A9MEM3210.

                      Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                      We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                       

                      What are the power terminal sizes on the A9MEM3100?

                      The power terminal sizes of the iEM3100 meter will take 16mm cable
                      see instruction sheet....https://eshop.schneider-electric.com/Download.aspx?infos=H808089_1.pdf;3

                      What is the replacement for 15467 Power meter with 100/5 CTs?

                      What is the part number for Single phase KWH meter?

                      The part number for Single phase KWH meter will be a - A9MEM2105.
                      Please refer the below link for more information,
                      https://www.schneider-electric.com/en/product/A9MEM2105/modular-single-phase-power-meter-iem2105---230v---63a-with-pulse/
                      Image result for a9mem2105 schneider



                       

                      Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                      The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                       
                      Show More