iEM2000 Series iEM2110 Product Image

iEM2000 Series Modular Single Phase Power Meter, 230V, 63A, With Pulse, MID

Catalogue Number: A9MEM2110
iEM2000 Series iEM2110 Product Image
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Acti 9
Product name
Acti 9 iEM2100
Device short name
iEM2110
Product or component type
energy meter
Market segment
Poles description
1P + N
Type of measurement
  • active and reactive energy
  • active and reactive power
  • current
  • voltage
    • Metering type
      active, reactive, apparent energy (signed, four quadrant)
      Device application
    • sub billing
    • partial meter
    • multi-tariff
      • Accuracy class
      • class 1 active energy conforming to IEC 62053-21
      • class B active energy conforming to EN 50470-3
      • class 2 reactive energy conforming to IEC 62053-23
        • Analogue input type
          direct input
          [In] rated current
          63 A
          Rated voltage
          230-230 V +/- 20 %
          Network frequency
        • 60 Hz
        • 50 Hz
          • Frequency measurement range
            45-65 Hz
            Technology type
            electronic
            Display type
            LCD display
            Sampling rate
            32 samples/cycle
            Measurement current
            0-63 A
            Display digits
            8
            Maximum value measured
            999999.99 kWh
            Information displayed
            tariff (2)
            Communication port protocol
            -
            Communication port support
            -
            Local signalling
            red LED: accuracy checking 1...1000 p/kWh
            Number of inputs
            1-1 digital
            Number of outputs
            2 pulse
            Output voltage
          • 3...33 V AC@90 mA
          • 5...70 V DC@90 mA
            • Impulse duration
              30...100 ms
              [Us] rated supply voltage
              96...276 V AC 50 Hz
              Maximum power consumption in VA
              2 VA
              Maximum power consumption in W
              1 W
              [Uimp] rated impulse withstand voltage
              6 kV 1.2/50 µs
              Mounting mode
              clip-on
              Mounting support
              DIN rail
              Connections - terminals
            • power circuit: tunnel type terminals (bottom) 1 1.65-33 mm² cable(s) solid
            • power circuit: tunnel type terminals (bottom) 1 1.65-33 mm² cable(s) stranded with cable end
            • pulse output: screw clamp terminals (top) 1 1-4 mm² cable(s) solid
            • pulse output: screw clamp terminals (top) 1 1-2.5 mm² cable(s) stranded with cable end
              • Tightening torque
              • power circuit: 2-2 N.m PZ2 screwdriver
              • pulse output: 0.5-0.5 N.m3.5 mm
                • Wire stripping length
                • power circuit: 17 mm
                • pulse output: 6 mm
                  • Standards
                  • IEC 62053-31
                  • IEC 62052-31
                  • IEC 62053-21
                  • IEC 62053-23
                  • IEC 62052-11
                    • Product certifications
                    • MID conforming to EN 50470-1
                    • MID conforming to EN 50470-3
                    • CE
                      • Compatibility code
                        iEM2110
                        IP degree of protection
                        IP20 conforming to IEC 60529
                        Overvoltage category
                        III
                        Pollution degree
                        2
                        Flame retardance
                        V0 conforming to UL 94
                        Ambient air temperature for operation
                        -25-55 °C
                        Ambient air temperature for storage
                        -25-70 °C
                        Relative humidity
                        0-95 %
                        9 mm pitches
                        4
                        Width
                        36 mm
                        Height
                        90 mm
                        Depth
                        64 mm
                        Net weight
                        0.175 kg
                        EU RoHS Directive
                        Compliant
                        Toxic heavy metal free
                        Yes
                        Mercury free
                        Yes
                        RoHS exemption information
                        Yes
                        China RoHS Regulation
                         Pro-active China RoHS declaration (out of China RoHS legal scope)

                        Documents & downloads

                        hide show
                        Filter items
                        • All

                        • CAD Files and Packs

                        • Product Brochures

                        • Movies

                        • Technical Data Catalogues

                        • Technical Leaflet

                        • Installation Instruction

                        • Product Environmental

                        • End of Life Manual

                        • Operating Manuals

                        • Certificates (MSDS)

                        • Declaration of Conformity

                        • White Paper

                        • Software - Updates

                        Frequently Asked Questions

                        hide show

                        Is the Acti 9 A9MEM3110 3 phase?

                        Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                        What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

                        The product code is A9MEM2000. Please see the attached datasheet for more information.
                         

                        What is the alternate part number for 17072

                         Replacement is a A9MEM3210

                        What is the alternative code for 17072?

                        A9MEM3210

                        ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                        The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                        What is the replacement for a 17072

                         The replacement is a A9MEM3210.

                        What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                        A9MEM3155 - 16mm
                        A9MEM3355 - 50mm
                        For further information , visit links below:-
                        https://www.schneider-electric.com.au/en/search/A9MEM3155
                        https://www.schneider-electric.com.au/en/search/A9MEM3355
                        User-added image

                        What are the power terminal sizes on the A9MEM3100?

                        The power terminal sizes of the iEM3100 meter will take 16mm cable
                        see instruction sheet....https://eshop.schneider-electric.com/Download.aspx?infos=H808089_1.pdf;3

                        What is the replacement for 15467 Power meter with 100/5 CTs?

                        What is the part number for Single phase KWH meter?

                        The part number for Single phase KWH meter will be a - A9MEM2105.
                        Please refer the below link for more information,
                        https://www.schneider-electric.com/en/product/A9MEM2105/modular-single-phase-power-meter-iem2105---230v---63a-with-pulse/
                        Image result for a9mem2105 schneider



                         

                        Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                        We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                         

                        What are the Dimensions for the A9MEM2000 single phase power meter?

                          9 mm pitches 2  
                         
                         
                          Width 18 mm  
                         
                         
                          Height 95 mm  
                         
                         
                          Depth 67 mm  
                         
                         
                          Product weight 0.073 kg  

                        Can Rogowski Coil Current Transformers (Rope Style CT's) Be Extended in the Field? How Far?

                        Issue
                        Rogowski Coil CT's may require secondary lead length extension.

                        Product Line
                        A9MEM3500 meters
                        EM4200 meters
                        EM3500 meters
                        U018 Rogowski Coil Current Transformers

                        Environment
                        Metering & Power Monitoring

                        Cause
                        The load may be farther from the meter than the standard 8' or 12' secondary lead lengths may reach.

                        Resolution
                        Schneider Rogowski Coil Current Transformers come in primary lengths of 12", 18", 24", or 36". 
                        This measurement only applies to the primary length only.
                        This is the length that the current transformer has to connect back to itself around a conductor or set of conductors of the load to be monitored.

                        The lead length refers to the 8' or 12' that connects from the current transformer to the meter itself.

                        It is sometimes difficult to get the meter mounting location within 8' or 12' from an appropriate location to install the current transformer on the load conductors.
                        Because of this, one may need to extend the length of the secondary leads from the current transformers.

                        Either the 8' or the 12' secondary lead length version of Schneider's Rogowski Coil (U018-xxx) Current Transformers may be extended to a maximum of 20' total lead length (to include the original lead length of either 8' or 12').
                        The conductors used must be a standard 24 gauge twisted cable.

                        Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                        The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                         

                        Which KWH meter will measure Solar inputs with Modbus connections?

                        On the PowerTag A9 F63 model, ref. A9MEM1562 if I try to be consistent with the flat cable position, the LED of the module is upwards. Should I twist the flat cable to have the LED down?

                        This has no impact on the operation but to be consistent with the rest of the range we favor the Led down, and in this case, the flat cable is twisted.

                        AM-C921-100 Port Pinouts

                        Goals and Symptoms

                        The purpose of this resolution is to document the 984 Chassis Mount AM-C921-100 Communications Processor port pinouts.

                        Causes and Fixes

                        See Attachments for C921 connector port locations and pinouts.

                        Attachments

                        (Removed File URL: 187468_20E6/C921-101.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/7f37013e71000763c125733200160dc1/fl_block_5/0.54E?OpenElement&FieldElemFormat=gif) (Removed File URL: 187468_20E6/C921_Ports.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/7f37013e71000763c125733200160dc1/fl_block_5/0.1038?OpenElement&FieldElemFormat=gif)


                        Legacy KB System (APS) Data: RESL187468 V1.0, Originally authored by WeDa on 08/09/2007, Last Edited by WeDa on 08/09/2007
                        Related ranges: Modicon 1/2/3/4/5/8/984s

                        Power Meter Communication issue, registers not reading the correct value.

                        The Power meters, based on the manufacturing location may have an offset. 

                        In some meters the registers starts from Zero and some it is taken account from 1. So the published register list varies accordingly. 

                        For Ex: If Register 2017 is for Frequency of the meters it will read 50 HZ. 
                        But for the meter with offset the the Register 2016 will read 50HZ. 

                        So it is good to check if the meter has got an Offset before proceeding with the communication issue. 

                        Can the IEM3000 series read energy output from a Solar Panel?

                        To be able to measure the energy out from a Solar Panel a meter needs to be able to do Four Quadrant Calculation.

                        This means it is capable of Identification of imported and exported active and reactive energy allows you to monitor energy flow in both directions: delivered from the utility and produced on-site.

                        In the iEM3000 series the following meters are capable of Four Quadrant Calculation.

                        iEM31** range - iEM3135, iEM3155, iEM3165, and iEM3175
                        iEM32** range - iEM3235, iEM3255, iEM3265, and iEM3275
                        iEM33** range - iEM3335, iEM3355, iEM3365, and iEM3375
                        iEM34** range - iEM3455, iEM3465, iEM3555, and iEM3565