Range
Acti 9
Product name
Acti 9 iEM2000
Device short name
iEM2000T
Product or component type
energy meter
Market segment
Poles description
1P + N
Type of measurement
active power
Device application
sub billing
Accuracy class
class 1 active energy conforming to IEC 62053-21
Analogue input type
direct input
[In] rated current
40 A
Rated voltage
230-230 V +/- 20 %
Network frequency
  • 60 Hz
  • 50 Hz
    • Frequency measurement range
      48-62 Hz
      Technology type
      electronic
      Display type
      without display
      Sampling rate
      32 samples/cycle
      Measurement current
      0-40 A
      Display digits
      0
      Maximum value measured
      999999.9 kWh
      Communication port protocol
      -
      Communication port support
      -
      Local signalling
    • green indicator light: power ON
    • yellow indicator light: metering and activity 3200 p/kWh
      • Number of inputs
        0-0
        Number of outputs
        1 pulse
        Output voltage
        5...35 V DC@20 mA
        Impulse duration
        120 ms
        Maximum power consumption in VA
        10 VA
        Mounting mode
        clip-on
        Mounting support
        DIN rail
        Connections - terminals
      • power circuit: tunnel type terminals (bottom) 1 10-10 mm² cable(s)
      • remote transfer: tunnel type terminals (top) 1 4-4 mm² cable(s)
        • Tightening torque
        • power circuit: 1.2-1.2 N.m
        • remote transfer: 0.8-0.8 N.m
          • Standards
          • IEC 61557-12
          • IEC 62053-21
            • Product certifications
              CE
              Market segment
            • residential
            • small commercial
              • Compatibility code
                iEM2000T
                IP degree of protection
                IP40 conforming to IEC 60529
                Ambient air temperature for operation
              • -20-70 °C < 32 A
              • -20-55 °C >= 32 A
                • Ambient air temperature for storage
                  -40-70 °C
                  Relative humidity
                  0-95 % at 55-55 °C
                  9 mm pitches
                  2
                  Width
                  18 mm
                  Height
                  95 mm
                  Depth
                  67 mm
                  Net weight
                  0.073 kg
                  Sustainable offer status
                  Green Premium product
                  EU RoHS Directive
                  Compliant
                  Mercury free
                  Yes
                  RoHS exemption information
                  Yes
                  China RoHS Regulation
                  X
                  Environmental Disclosure
                  ENVPEP090502EN
                  Circularity Profile
                  ENVEOLI090601EN
                  Warranty
                  18 months

                  Documents & downloads

                  hide show
                  Filter items
                  • All

                  • CAD Files and Packs

                  • Product Brochures

                  • Movies

                  • Technical Data Catalogues

                  • Catalog Page

                  • Technical Leaflet

                  • Installation Instruction

                  • Product Environmental

                  • End of Life Manual

                  • Data Bulletin

                  • Operating Manuals

                  • Specification for Tender

                  • Specifications

                  • Application Solutions

                  • Case Studies

                  • White Paper

                  • Declaration of Conformity

                  • Certificates (MSDS)

                  • Software - Demos & Trial

                  • Software - Updates

                  • Software - Released

                  Frequently Asked Questions

                  hide show

                  What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

                  The product code is A9MEM2000. Please see the attached datasheet for more information.
                   

                  What are the power terminal sizes on the A9MEM3100?

                  The power terminal sizes of the iEM3100 meter will take 16mm cable
                  see instruction sheet....https://eshop.schneider-electric.com/Download.aspx?infos=H808089_1.pdf;3

                  What are the Dimensions for the A9MEM2000 single phase power meter?

                    9 mm pitches 2  
                   
                   
                    Width 18 mm  
                   
                   
                    Height 95 mm  
                   
                   
                    Depth 67 mm  
                   
                   
                    Product weight 0.073 kg  

                  What is the replacement for a 17072

                   The replacement is a A9MEM3210.

                  ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                  The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                  What is the part number for Single phase KWH meter?

                  The part number for Single phase KWH meter will be a - A9MEM2105.
                  Please refer the below link for more information,
                  https://www.schneider-electric.com/en/product/A9MEM2105/modular-single-phase-power-meter-iem2105---230v---63a-with-pulse/
                  Image result for a9mem2105 schneider



                   

                  Is the Acti 9 A9MEM3110 3 phase?

                  Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                  What is the alternate part number for 17072

                   Replacement is a A9MEM3210

                  What is the alternative code for 17072?

                  A9MEM3210

                  Can Rogowski Coil Current Transformers (Rope Style CT's) Be Extended in the Field? How Far?

                  Issue
                  Rogowski Coil CT's may require secondary lead length extension.

                  Product Line
                  A9MEM3500 meters
                  EM4200 meters
                  EM3500 meters
                  U018 Rogowski Coil Current Transformers

                  Environment
                  Metering & Power Monitoring

                  Cause
                  The load may be farther from the meter than the standard 8' or 12' secondary lead lengths may reach.

                  Resolution
                  Schneider Rogowski Coil Current Transformers come in primary lengths of 12", 18", 24", or 36". 
                  This measurement only applies to the primary length only.
                  This is the length that the current transformer has to connect back to itself around a conductor or set of conductors of the load to be monitored.

                  The lead length refers to the 8' or 12' that connects from the current transformer to the meter itself.

                  It is sometimes difficult to get the meter mounting location within 8' or 12' from an appropriate location to install the current transformer on the load conductors.
                  Because of this, one may need to extend the length of the secondary leads from the current transformers.

                  Either the 8' or the 12' secondary lead length version of Schneider's Rogowski Coil (U018-xxx) Current Transformers may be extended to a maximum of 20' total lead length (to include the original lead length of either 8' or 12').
                  The conductors used must be a standard 24 gauge twisted cable.