Quantcast

Acti 9 PowerTag 1P+N -Bottom - Max 63A - Energy Sensor with RCBO feeding plate

Acti 9 PowerTag 1P+N -Bottom - Max 63A - Energy Sensor with RCBO feeding plate

Acti 9 PowerTag 1P+N -Bottom - Max 63A - Energy Sensor with RCBO feeding plate

Item Number: A9MEM1563

Retail
$254.10
RRP (Inc. GST)

Product Dimensions

Width icon

Width

  • sensor element: 18 mm
  • base unit: 18 mm
    Height icon

    Height

  • sensor element: 20 mm
  • base unit: 8 mm
    Depth icon

    Depth

  • sensor element: 44.5 mm
  • base unit: 28 mm

    Datasheet

    Barcode

    Qty UoM EAN Colour
    -
    -
    -

    Specifications

    Design

    Sustainable offer status

    Green Premium product

    Range

    PowerLogic

    Product or component type

    energy sensor

    Market segment

  • buildings: breaker voltage monitoring
  • buildings: cost allocation
  • buildings: overload alarm
    • Product destination

      switchboard

      Physical

      Circularity Profile

      ENVEOLI1605012

      Environmental Disclosure

      ENVPEP1605012

      Mercury free

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      EU RoHS Directive

      Compliant

      RoHS exemption information

      Yes

      Range compatibility

    • Acti 9 iKQE RCBO
    • Acti 9 iC60 iC60H RCBO
    • Acti 9 iC60 iC60H2 RCBO
      • Mounting support

        on circuit breaker

        Mounting mode

        by screws (terminals)

        [Ue] rated operational voltage

        200...240 V AC, +/- 20 %

        Standards

      • IEC 61557-12
      • IEC 61010-1
      • IEC 61010-2-030
      • IEC 61326-1
      • ETSI EN 300 328
        • Height

        • sensor element: 20 mm
        • base unit: 8 mm
          • Width

          • sensor element: 18 mm
          • base unit: 18 mm
            • Depth

            • sensor element: 44.5 mm
            • base unit: 28 mm
              • Net weight

                18 g

                Ambient air temperature for operation

                -25-60 °C

                Ambient air temperature for storage

                -40-85 °C

                IP degree of protection

                IP20 conforming to IEC 60529

                IK degree of protection

                IK05

                Relative humidity

                0-95 % at 45-45 °C conforming to IEC 60721-3-3

                Environmental characteristic

              • dustproof class 3S3 conforming to IEC 60721-3-3
              • salt mist class 3C2 conforming to IEC 60721-3-3
              • indoor use
                • Others

                  Package 1 Height

                  6.5 cm

                  Package 1 Length

                  8 cm

                  Package 1 Weight

                  0.063 kg

                  Package 1 width

                  7.5 cm

                  WEEE

                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                  Product name

                  PowerTag A9 P63

                  Poles description

                  1P + N

                  Max current

                  63 A

                  [Ib] basic current

                  10 A

                  Starting current

                  40 mA

                  Saturation current

                  130 A

                  Product specific application

                • load monitoring
                • cost allocation
                • overload alarm
                • circuit monitoring
                • energy management
                  • Concentrator compatibility

                  • Acti9 Smartlink SI B
                  • Acti9 Smartlink SI D
                  • Acti9 PowerTag Link C
                  • Acti9 PowerTag Link
                  • Acti9 PowerTag Link HD
                    • Type of measurement

                    • active power
                    • power factor
                    • active energy
                    • current
                    • voltage
                      • Accuracy class

                      • class 1 current conforming to IEC 61557-12
                      • class 0.5 voltage conforming to IEC 61557-12
                      • class 1 active power conforming to IEC 61557-12
                      • class 1 active energy conforming to IEC 61557-12
                      • class 1 power factor conforming to IEC 61557-12
                        • Mounting location

                          bottom

                          Connection pitch

                          9 mm Ph/N

                          Event management

                          voltage loss with measured current at voltage loss

                          Transmission support medium

                          radio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4

                          Maximum emission power

                          10 mW

                          Form factor

                          phaseNeutral

                          Electrical connection

                          connector tooth

                          Cable cross section

                        • 1 rigid cable 1.5-16 mm²
                        • 2 stranded cable 1.5-2.5 mm²
                        • 2 rigid cable 1.5-2.5 mm²
                        • 1 stranded cable 1.5-16 mm²
                          • Network frequency

                          • 50 Hz
                          • 60 Hz
                            • Maximum power consumption in VA

                              1 VA

                              Compatibility code

                              PowerTag A9 F63

                              Quality labels

                              CE

                              Directives

                              2014/53/EU - radio equipment directive

                              Operating altitude

                              0...2000 m

                              Overvoltage category

                              III conforming to IEC 61010-1

                              Measurement category

                              category III conforming to IEC 61010-2-030

                              Pollution degree

                              3

                              Vibration resistance

                              3M4 conforming to IEC 60721-3-3
                              Show all specifications

                              Documents & downloads

                              hide show
                              Filter items
                              • All

                              • CAD Files and Packs

                              • Product Brochures

                              • Technical Data Catalogues

                              • Catalogue Page

                              • Installation Instruction

                              • Product Environmental

                              • End of Life Manual

                              • Operating Manuals

                              • Certificates (MSDS)

                              • Software - Hotfix & Patch

                              Frequently Asked Questions

                              hide show

                              On the PowerTag A9 F63 model, ref. A9MEM1562 if I try to be consistent with the flat cable position, the LED of the module is upwards. Should I twist the flat cable to have the LED down?

                              This has no impact on the operation but to be consistent with the rest of the range we favor the Led down, and in this case, the flat cable is twisted.

                              What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                              A9MEM3155 - 16mm
                              A9MEM3355 - 50mm
                              For further information , visit links below:-
                              https://www.schneider-electric.com.au/en/search/A9MEM3155
                              https://www.schneider-electric.com.au/en/search/A9MEM3355
                              User-added image

                              Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                              We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                               

                              ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                              The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                              Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                              The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                               

                              Is the Acti 9 A9MEM3110 3 phase?

                              Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.
                              Show More