Acti 9 PowerTag 1P+N -Bottom - Max 63A - Energy Sensor with RCBO feeding plate

Acti 9 PowerTag 1P+N -Bottom - Max 63A - Energy Sensor with RCBO feeding plate

Acti 9 PowerTag 1P+N -Bottom - Max 63A - Energy Sensor with RCBO feeding plate

Item Number: A9MEM1563

Retail
$254.10
RRP (Inc. GST)

Product Dimensions

Width icon

Width

  • sensor element: 18 mm
  • base unit: 18 mm
    Height icon

    Height

  • sensor element: 20 mm
  • base unit: 8 mm
    Depth icon

    Depth

  • sensor element: 44.5 mm
  • base unit: 28 mm
    See full specifications

    Datasheet

    Barcode

    Qty UoM EAN Colour
    -
    -
    -

    Specifications

    Design

    Range

    PowerLogic

    Product or component type

    energy sensor

    Market segment

  • buildings: breaker voltage monitoring
  • buildings: cost allocation
  • buildings: overload alarm
    • Product destination

      switchboard

      Sustainable offer status

      Green Premium product

      Physical

      Range compatibility

    • Acti 9 iKQE RCBO
    • Acti 9 iC60 iC60H RCBO
    • Acti 9 iC60 iC60H2 RCBO
      • Mounting support

        on circuit breaker

        Mounting mode

        by screws (terminals)

        [Ue] rated operational voltage

        200...240 V AC, +/- 20 %

        Standards

      • IEC 61557-12
      • IEC 61010-1
      • IEC 61010-2-030
      • IEC 61326-1
      • ETSI EN 300 328
        • Height

        • sensor element: 20 mm
        • base unit: 8 mm
          • Width

          • sensor element: 18 mm
          • base unit: 18 mm
            • Depth

            • sensor element: 44.5 mm
            • base unit: 28 mm
              • Net weight

                18 g

                Ambient air temperature for operation

                -25-60 °C

                Ambient air temperature for storage

                -40-85 °C

                IP degree of protection

                IP20 conforming to IEC 60529

                IK degree of protection

                IK05

                Relative humidity

                0-95 % at 45-45 °C conforming to IEC 60721-3-3

                Environmental characteristic

              • dustproof class 3S3 conforming to IEC 60721-3-3
              • salt mist class 3C2 conforming to IEC 60721-3-3
                • EU RoHS Directive

                  Compliant

                  Mercury free

                  Yes

                  RoHS exemption information

                  Yes

                  China RoHS Regulation

                  Product out of China RoHS scope. Substance declaration for your information

                  Environmental Disclosure

                  ENVPEP1605012

                  Circularity Profile

                  ENVEOLI1605012

                  Others

                  Product name

                  PowerTag A9 P63

                  Poles description

                  1P + N

                  Max current

                  63 A

                  [Ib] basic current

                  10 A

                  Starting current

                  40 mA

                  Saturation current

                  130 A

                  Product specific application

                • load monitoring
                • cost allocation
                • overload alarm
                • circuit monitoring
                • energy management
                  • Concentrator compatibility

                  • Acti9 Smartlink SI B
                  • Acti9 Smartlink SI D
                  • Acti9 PowerTag Link C
                  • Acti9 PowerTag Link
                  • Acti9 PowerTag Link HD
                    • Type of measurement

                    • active power
                    • power factor
                    • active energy
                    • current
                    • voltage
                      • Accuracy class

                      • class 1 current conforming to IEC 61557-12
                      • class 0.5 voltage conforming to IEC 61557-12
                      • class 1 active power conforming to IEC 61557-12
                      • class 1 active energy conforming to IEC 61557-12
                      • class 1 power factor conforming to IEC 61557-12
                        • Mounting location

                          bottom

                          Connection pitch

                          9 mm Ph/N

                          Event management

                          voltage loss with measured current at voltage loss

                          Transmission support medium

                          radio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4

                          Maximum emission power

                          10 mW

                          Form factor

                          phaseNeutral

                          Electrical connection

                          connector tooth

                          Cable cross section

                        • 1 rigid cable 1.5-16 mm²
                        • 2 stranded cable 1.5-2.5 mm²
                        • 2 rigid cable 1.5-2.5 mm²
                        • 1 stranded cable 1.5-16 mm²
                          • Network frequency

                          • 50 Hz
                          • 60 Hz
                            • Maximum power consumption in VA

                              1 VA

                              Compatibility code

                              PowerTag A9 F63

                              Quality labels

                              CE

                              Directives

                              2014/53/EU - radio equipment directive

                              Operating altitude

                              0...2000 m

                              Overvoltage category

                              III conforming to IEC 61010-1

                              Measurement category

                              category III conforming to IEC 61010-2-030

                              Pollution degree

                              3

                              Vibration resistance

                              3M4 conforming to IEC 60721-3-3

                              Package 1 Weight

                              0.063 kg

                              Package 1 Height

                              6.5 cm

                              Package 1 width

                              7.5 cm

                              Package 1 Length

                              8 cm

                              WEEE

                              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                              Show all specifications

                              Documents & downloads

                              hide show
                              Filter items
                              • All

                              • CAD Files and Packs

                              • Product Brochures

                              • Technical Data Catalogues

                              • Catalog Page

                              • Installation Instruction

                              • Product Environmental

                              • End of Life Manual

                              • Operating Manuals

                              • Certificates (MSDS)

                              Frequently Asked Questions

                              hide show

                              On the PowerTag A9 F63 model, ref. A9MEM1562 if I try to be consistent with the flat cable position, the LED of the module is upwards. Should I twist the flat cable to have the LED down?

                              This has no impact on the operation but to be consistent with the rest of the range we favor the Led down, and in this case, the flat cable is twisted.

                              What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                              A9MEM3155 - 16mm
                              A9MEM3355 - 50mm
                              For further information , visit links below:-
                              https://www.schneider-electric.com.au/en/search/A9MEM3155
                              https://www.schneider-electric.com.au/en/search/A9MEM3355
                              User-added image

                              Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                              We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                               

                              ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                              The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                              Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                              The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                               

                              Is the Acti 9 A9MEM3110 3 phase?

                              Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                              What are the power terminal sizes on the A9MEM3100?

                              The power terminal sizes of the iEM3100 meter will take 16mm cable
                              see instruction sheet....https://eshop.schneider-electric.com/Download.aspx?infos=H808089_1.pdf;3

                              What is the alternate part number for 17072

                               Replacement is a A9MEM3210

                              What is the alternative code for 17072?

                              A9MEM3210

                              Can Rogowski Coil Current Transformers (Rope Style CT's) Be Extended in the Field? How Far?

                              Issue
                              Rogowski Coil CT's may require secondary lead length extension.

                              Product Line
                              A9MEM3500 meters
                              EM4200 meters
                              EM3500 meters
                              U018 Rogowski Coil Current Transformers

                              Environment
                              Metering & Power Monitoring

                              Cause
                              The load may be farther from the meter than the standard 8' or 12' secondary lead lengths may reach.

                              Resolution
                              Schneider Rogowski Coil Current Transformers come in primary lengths of 12", 18", 24", or 36". 
                              This measurement only applies to the primary length only.
                              This is the length that the current transformer has to connect back to itself around a conductor or set of conductors of the load to be monitored.

                              The lead length refers to the 8' or 12' that connects from the current transformer to the meter itself.

                              It is sometimes difficult to get the meter mounting location within 8' or 12' from an appropriate location to install the current transformer on the load conductors.
                              Because of this, one may need to extend the length of the secondary leads from the current transformers.

                              Either the 8' or the 12' secondary lead length version of Schneider's Rogowski Coil (U018-xxx) Current Transformers may be extended to a maximum of 20' total lead length (to include the original lead length of either 8' or 12').
                              The conductors used must be a standard 24 gauge twisted cable.

                              What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

                              The product code is A9MEM2000. Please see the attached datasheet for more information.
                               

                              Which KWH meter will measure Solar inputs with Modbus connections?

                              Show More