Acti9 iC60H, 2P, 50A, D Miniature Circuit Breaker

Acti9 iC60H, 2P, 50A, D Miniature Circuit Breaker

Acti9 iC60H, 2P, 50A, D Miniature Circuit Breaker

Item Number: A9F55250

Retail
$395.45
RRP (Inc. GST)

Product Dimensions

Width icon

Width36 mm

Height icon

Height85 mm

Depth icon

Depth78.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Acti 9

Range of product

Acti 9

Product or component type

miniature circuit-breaker

Sustainable offer status

Green Premium product

Physical

[In] rated current

50 A

[Ue] rated operational voltage

440 V AC 50/60 Hz

Control type

toggle

Local signalling

trip indicator

Mounting mode

clip-on

Mounting support

rail

Height

85 mm

Width

36 mm

Depth

78.5 mm

Net weight

0.25 kg

Mechanical durability

20000 cycles

Electrical durability

10000 cycles

Connections - terminals

  • single terminal (top or bottom) 1-35 mm² rigid
  • single terminal (top or bottom) 1-25 mm² flexible
    • Wire stripping length

      14 mm for top or bottom connection

      Standards

    • EN/IEC 60947-2
    • EN/IEC 60898-1
      • IP degree of protection

        IP20 conforming to IEC 60529

        Relative humidity

        95-95 % at 55-55 °C

        Ambient air temperature for operation

        -35-70 °C

        Ambient air temperature for storage

        -40-85 °C

        REACh free of SVHC

        Yes

        EU RoHS Directive

        Compliant

        Toxic heavy metal free

        Yes

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

         Pro-active China RoHS declaration (out of China RoHS legal scope)

        Environmental Disclosure

        ENVPEP1409009EN

        Others

        Product name

        Disbo iC60

        Device short name

        iC60H

        Poles description

        2P

        Number of protected poles

        2

        Network type

        AC

        Trip unit technology

        thermal-magnetic

        Curve code

        D

        Breaking capacity code

        H

        Breaking capacity

      • 10 kA Icu at 100...133 V DC conforming to EN/IEC 60947-2
      • 10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
      • 42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
      • 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
      • 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
      • 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
        • Utilisation category

          category A conforming to EN/IEC 60947-2

          Network frequency

          50/60 Hz

          Magnetic tripping limit

          12 x In +/- 20 %

          [Ics] rated service breaking capacity

        • 21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz
        • 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz
        • 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz
        • 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
        • 7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
        • 10 kA 100 % conforming to EN/IEC 60947-2 - 100...133 V DC
          • Limitation class

            3 conforming to EN/IEC 60947-2

            [Ui] rated insulation voltage

            500 V AC 50/60 Hz conforming to EN/IEC 60947-2

            [Uimp] rated impulse withstand voltage

            6 kV conforming to EN/IEC 60947-2

            Contact position indicator

            yes

            Connection pitch

            9 mm pitches

            4

            Provision for padlocking

            padlockable

            Tightening torque

            3.5-3.5 N.m top or bottom

            Earth-leakage protection

            separate block

            Compatibility code

            iC60

            Pollution degree

            3 conforming to EN/IEC 60947-2

            Tropicalisation

            2 conforming to IEC 60068-1

            Package 1 Weight

            0.25 kg

            Package 1 Height

            0.75 dm

            Package 1 width

            0.36 dm

            Package 1 Length

            0.9 dm

            WEEE

            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
            Show all specifications

            Frequently Asked Questions

            hide show

            What is the part number for a 3 phase, D-Curve, 50A breaker?

            The part number for a 3 phase, D-Curve, 50A breaker is a  - A9F55350.

            What is the code for 4 pole 10kA 50A D curve MCB?

            Code = A9f55450  (iC60H) 

            What is the part number for 20A 10kA D curve 3 pole circuit breaker?

            The part number for 20A 10kA D curve 3 pole circuit breaker is A9F55320.

            What protective devices are required for EV Chargers?

            Protective devices which are required for EV chargers can be either RCBO or MCB+RCCB. 

            For 1P 16A  => 3,7Kw load    protection devices = 20A curve C + type B 30mA ( A9F54220 + A9Z51240)
            For 1P 32A  => 7Kw load       protection devices = 40A curve C + type B 30mA  ( A9F54240 + A9Z51240)
            For 3P 16A  => 11Kw load     protection devices = 20A curve C + type B 30mA  ( A9F54420 + A9Z51440)
            For 3P 32A  => 22Kw load     protection devices = 40A curve C + type B 30mA  ( A9F54440 + A9Z51440)

            The circuit breaker value (20A or 40A) depends on the cable size, length and environmental parameters (up to the electrician)
            For further information see:https://www.se.com/au/en/product-subcategory/80408-evlink-charging-station/


             

            What items come with the KITWALLBOX7?

            A9Z51240 = Type B single phase RCCD
            A9F54240 = 2 pole, 40A, Curve MCB
            A9A26969 = Under voltage release

            Data sheet for A9F54240 ?

            Data sheet attached
            Show More