iDPN N Vigi

Acti 9 iDPN N Vigi, RCBO, 1P+N, 6A, C Curve, 6000A, 30mA, Type A

Catalogue Number: A9D32606
iDPN N Vigi
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
iDPN Vigi
Range
Acti 9
Product name
Acti 9 iDPN Vigi
Product or component type
residual current breaker with overcurrent protection (RCBO)
Device short name
iDPN N Vigi
Device application
distribution
Poles description
1P + N
Number of protected poles
1
Neutral position
left
[In] rated current
6 A
Network type
AC
Trip unit technology
thermal-magnetic
Curve code
C
Earth-leakage sensitivity
30 mA
Earth-leakage protection time delay
instantaneous
Earth-leakage protection class
type A
Breaking capacity
6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Suitability for isolation
yes conforming to EN/IEC 60947-2
Device location in system
outgoer
Network frequency
50 Hz
[Ue] rated operational voltage
220...240 V AC 50 Hz
Magnetic tripping limit
5...10 x In
Residual current tripping technology
voltage independent
[Ics] rated service breaking capacity
6000 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacity
Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class
3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage
400 V AC 50 Hz
[Uimp] rated impulse withstand voltage
4 kV
Contact position indicator
yes
Control type
toggle
Local signalling
ON, OFF, fault trip
Mounting mode
clip-on
Mounting support
DIN rail
Comb busbar and distribution block compatibility
top or bottom: YES
Connection pitch
9 mm pitches
4
Height
85 mm
Width
36 mm
Depth
73 mm
Net weight
125 g
Mechanical durability
20000 cycles
Electrical durability
20000 cycles
Locking options description
padlocking device
Connections - terminals
  • single terminal top or bottom 1-16 mm² rigid
  • single terminal top or bottom 1-10 mm² flexible
  • single terminal top or bottom 1-10 mm² flexible with ferrule
    • Wire stripping length
      15 mm for top or bottom connection
      Tightening torque
      2-2 N.m top or bottom
      Earth-leakage protection
      integrated
      Market segment
    • residential
    • small commercial
      • Compatibility code
        iDPN
        Standards
        EN/IEC 61009-2-1
        Product certifications
      • VDE
      • KEMA
      • RCM
        • IP degree of protection
        • IP20 conforming to IEC 60529
        • IP40 (modular enclosure) conforming to IEC 60529
          • Pollution degree
            3
            Overvoltage category
            III conforming to IEC 60364
            Electromagnetic compatibility
            8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
            Tropicalisation
            2 conforming to IEC 60068-1
            Relative humidity
            95-95 % at 55-55 °C
            Ambient air temperature for operation
            -25-60 °C
            Ambient air temperature for storage
            -40-85 °C
            Sustainable offer status
            Green Premium product
            REACh Regulation
            Free of Substances of Very High Concern above the threshold
            EU RoHS Directive
            Compliant
            Mercury free
            Yes
            RoHS exemption information
            Yes
            China RoHS Regulation
            Product out of China RoHS scope. Substance declaration for your information
            Environmental Disclosure
            ENVPEP111021EN
            WEEE
            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
            Warranty
            18 months

            Frequently Asked Questions

            hide show

            What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

             
             

            A9D33620 = SI (Super Immunised)
            A9D32620 = Type A (AC or pulsating DC)

            Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
            Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
             

            What is the Acti-9 replacement for the Multi-9 19771?

            The Acti-9 replacement for the Multi-9 19771 is the A9D32606.

            What is the difference between the A9D73620 and A9D32620 RCBO's?

            The A9D73620 is the slimline RCBO which is the same rating and does the same as the A9D32620. It is just the physical size that is different.

            Where to find settings manual for MiCOM x3x Series?

            Issue 
            Need more information on settings on the MiCOM x3x.

            Product Line  
            MiCOM P13x
            MiCOM P23x
            MiCOM P43x
            MiCOM P53x
            MiCOM P63x

            Environment  
            Setting or Troubling settings

            Resolution    
            All the settings, measurements, recordings with option and configuration tables plus IEC - 103 telegram documentation/menu database can all be found in the Data Model Explorer.
            To get the Data Model Explorer needed just type in the MiCOM model need.  For example in Google type in MiCOM P438 for Data Model Explorer.  Click on the Schneider Electric result for the MiCOM P438 Data Model Explorer.
            It will bring up the following Data Model Explorer page https://www.schneider-electric.com/en/download/document/P438_DataModelExplorer_EN/
            On the site download the P438 that is needed. 
             

            Will the Compact NSX breaker be for sale in the USA or Canada?

            Issue:
            Where can I buy a Compact NSX breaker?

            Product Line:
            Circuit Breakers

            Cause:
            This breaker is popular overseas and there is interest in the US

            Resolution:
            There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

            If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

            For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
            https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page

            Why can't I purchase Schneider Electric US Lighting Control products any more?

            Issue:
            As of March 1, 2015 all US Lighting Control products (EXCEPT Powerlink and MVP panels) will enter their obsolescence phase and will no longer be purchasable for new orders. Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiative and concentrate our effort in new businesses with higher growth potential – Connected Home, Building Control in small buildings, and Electric Vehicle solutions.

            Product Line:
            All US Lighting Control product except Powerlink and MVP panels are affected. CBus, Occupancy Sensors, Low Voltage Switches, Relay Panels, Emergency Lighting Control Panels, Schneider Electric branded Current Limiting Panels, and Architectural Dimming Panels.

            Environment:
            US Lighting Control products

            Cause:
            Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiatives.

            Resolution:
            See cross reference sheet attached for available completive cross references.