iC60H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection

Acti 9 iC60H, Earth Leakage Circuit Breaker, 1P + N, C Curve, 45A, 30 mA, 240V

Catalogue Number: A9D11845
iC60H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection
Retail
$611.55*
RRP (Inc. GST)

Specifications

hide show
Circuit breaker application
distribution
Range
Acti 9
Range of product
Acti 9
Product name
Acti 9 iC60 RCBO
Product or component type
residual current breaker with overcurrent protection (RCBO)
Device short name
iC60H RCBO
Poles description
1P + N
[In] rated current
45 A at 50 °C
Earthing system
TN
Curve code
C
Earth-leakage sensitivity
30 mA
Breaking capacity
10000 A Icn at 240 V AC 50/60 Hz
Neutral position
left
Number of protected poles
1
Device location in system
outgoer
Network type
AC
Network frequency
50 Hz
[Ue] rated operational voltage
240 V AC 50/60 Hz
Trip unit technology
thermal-magnetic
Breaking capacity code
H
Residual current tripping technology
voltage dependent
Earth-leakage protection time delay
instantaneous
Earth-leakage protection class
type A
[Icw] rated short-time withstand current
Icw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacity
7500 A at 240 V AC 50/60 Hz
Limitation class
3
[Ui] rated insulation voltage
400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
4 kV
Surge current
250 A
Suitability for isolation
yes
Contact position indicator
yes
Control type
toggle
Local signalling
ON/OFF indication
Mounting mode
clip-on
Mounting support
DIN rail
Comb busbar and distribution block compatibility
NO
9 mm pitches
2
Height
110 mm
Width
18 mm
Depth
77.5 mm
Net weight
205 g
Mechanical durability
20000 cycles
Electrical durability
5000 cycles
Provision for padlocking
padlockable with padlock Ø 4 mm
Locking options description
ON/OFF locking facilities
Connections - terminals
  • screw clamp terminal (top) 1-25 mm² rigid without cable end
  • screw clamp terminal (top) 1-16 mm² flexible
  • screw clamp terminal (bottom) 1-16 mm² rigid without cable end
  • screw clamp terminal (bottom) 1-10 mm² flexible
    • Wire stripping length
    • power circuit: 13 mm for bottom connection
    • power circuit: 14 mm for top connection
      • Tightening torque
      • power circuit: 3.5-3.5 N.m top
      • power circuit: 2-2 N.m bottom
        • Earth-leakage protection
          integrated
          Standards
        • IEC 61009-1
        • AS/NZS 61009.1
        • BS EN 61009-1
        • IEC 61009-2-2
          • IP degree of protection
            IP20
            Tropicalisation
            2
            Relative humidity
            95-95 % at 55-55 °C
            Ambient air temperature for operation
            -15-60 °C
            Ambient air temperature for storage
            -40-85 °C
            Sustainable offer status
            Green Premium product
            REACh Regulation
            Free of Substances of Very High Concern above the threshold
            EU RoHS Directive
            Compliant
            Mercury free
            Yes
            RoHS exemption information
            Yes
            China RoHS Regulation
            Product out of China RoHS scope. Substance declaration for your information
            Environmental Disclosure
            ENVPEP121008EN
            Circularity Profile
            ENVEOLI121005EN
            WEEE
            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

            Documents & downloads

            hide show
            Filter items
            • All

            • Product Brochures

            • CAD Files and Packs

            • Technical Data Catalogues

            • Installation Instruction

            • End of Life Manual

            • Product Environmental

            • Certificates (MSDS)

            • Declaration of Conformity

            Frequently Asked Questions

            hide show

            What is the replacement part for a 26896 RCB?

            The replacement part is a A9D61820.
            A9D11220 is best solution
            A9D11820 is an alternative 1 pole wide but no Neutral switching
            A9D61820 is an alternative 1 pole wide but no Neutral switching and only 6kA
             

            What is the part number for a 45amp chassis style RCD/MCB combo C/B?

            The part number for a 45amp chassis style RCD/MCB combo C/B is - 6kA - A9D61845 , 10kA - A9D11845
            For further information, visit the link below:-
            https://www.schneider-electric.com.au/en/search/A9D61845
            https://www.schneider-electric.com.au/en/search/A9D11845
            User-added image
            User-added image

            What is the part number for an A9D11810 but in "D" curve?

            need to build up with "D" curve circuit breaker A9F55110 and vigi unit A9V02663
            for more details see ....... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F55110
            and ............... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9V02663
            User-added image    User-added image

            What is the part number for 2 pole 16amp RCBO 2 modules wide?

            The part name is A9D11216

            Does the A9D61816 RCBO have a neutral tail?

            Yes the A9D61816 and all that range have a neutral tail and also an Earth reference point.

            Does the A9D61816 RCBO have a neutral tail?

            Yes, the A9D61816 and all that range have a neutral tail and also an Earth reference point
            for more information see data sheet https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=a9d61816
            User-added image

            What is the alternative to the 4RCBE210/30?

            Within the Schneider Electric range, the alternative for the 4RCBE210/30 is A9D11210

            Is there a 20 amp, single GPO in the Metal Plate range?

            No. Unfortunately, there is no 20 version as a standard part but it can be ordered as a special based on the 10amp version.
            For more information, please refer to the link:https://www.clipsal.com/Trade/Products/ProductDetail?catno=A15A
             

            Which RCBO can ben used in hospitals?

            The only range of RCBO's that can be used in hospitals are:
            Electronic Models -
            4RCBE206/10 4RCBE206/10S
            4RCBE210/10  4RCBE210/10S
            4RCBE220/10 4RCBE220/10S
            4RCBE225/10 4RCBE225/10S
            4RCBE232/10 4RCBE232/10S
            4RCBE240/10  

            Unfortunately you cannot use Schneider A9D108** range as it doesnt switch the neutral.


            For further information see attached PDF or visit https://www.clipsal.com/Trade/search-results?q=4RCBE%20range&t=documentation



             

            How to Create a Data Log View for a Custom Data Recorder using ION Setup

            Issue

            A custom data recorder is not displayed in the list of ION Setup data log viewers.

            Product Line

            ION Setup

            Environment

            Viewing Custom Data Recorder

            Cause

            ​ION Setup only displays the default data log views for ION meters. If you add any custom data recorders to the meter, you must create a new .pml view table in order to view the data in those data recorders. The table needs to be manually updated.

            Resolution

            1. Determine the RE number of the newly added data recorder.  You do this by accessing the Advanced View mode and opening the setup register of the data recorder:


            2. Open the ION Setup default table under the following directory:
            ..\ION Setup\Tables\<meter type>\<Template Version>\Data Recorders

            3. Make a copy of an existing .pml files (e.g., select the Revenue Log). Rename this copy to match the name of the custom data recorder.

            4. You must replace two parameters in this file.  Change the LOG parameter to the RE number of the custom data recorder. Change the LABEL parameter to match the label of the custom data recorder.


            (R1 refers to row 1 of the table; C1 refers to column 1 of the table.)

            5. Exit Advanced Setup mode and change the ION Setup view mode to Data Screens.  The new view appears in the list.

            An alternative procedure with a little more details has been suggested to accomplish the same thing as follows:

            1.) Create a new datalog on the meter (an ION7650, for example). Take note of the label that you give this datalog for use in step 6 below. Take note of its number for step 7.

            2.) Go into "C:\Program Files\Schneider Electric\ION Setup\Tables\PML7650\Version 2.2 Default\Data Recorders".

            3.) Copy a Revenue Log and paste it to the same folder. Rename it (suggested name NewLog.pml).

            4.) Ensure that the "Read only" property for this new file is unchecked.

            5.) Open the NewLog.pml file (created in step 3 above) with notepad.

            6.) Change "LABEL=" property in the .pml text file to the name given to the datalog.

            7.) Changed the "LOG=" property in the .pml text file to the number of the new log module.

            8.) Change the "ROWS=" property in the .pml text file to 8640 (the default depth)

            9.) Exit Advanced Setup mode and change the ION Setup view mode to Data Screens.  The new view appears in the list.