iC60H2 RCBO 2P 10A…32A C 30mA with overcurrent protection

Acti 9 Ic60h2, Earth Leakage Circuit Breaker, 2P, C Curve, 10A, 30mA, 240V

Catalogue Number: A9D11210
iC60H2 RCBO 2P 10A…32A C 30mA with overcurrent protection
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Circuit breaker application
distribution
Range
Acti 9
Range of product
Acti 9
Product name
Acti 9 iC60 RCBO
Product or component type
residual current breaker with overcurrent protection (RCBO)
Device short name
iC60H2 RCBO
Poles description
2P
[In] rated current
10 A at 50 °C
Earthing system
  • TN
  • IT
  • TT
    • Curve code
      C
      Earth-leakage sensitivity
      30 mA
      Breaking capacity
      10000 A Icn at 240 V AC 50/60 Hz
      Neutral position
      left
      Number of protected poles
      2
      Device location in system
      outgoer
      Network type
      AC
      Network frequency
      50 Hz
      [Ue] rated operational voltage
      240 V AC 50/60 Hz
      Trip unit technology
      thermal-magnetic
      Breaking capacity code
      H2
      Residual current tripping technology
      voltage dependent
      Earth-leakage protection time delay
      instantaneous
      Earth-leakage protection class
      type A
      [Icw] rated short-time withstand current
      Icw: 250 A during 8/20 µs impulse withstand
      [Ics] rated service breaking capacity
      7500 A at 240 V AC 50/60 Hz
      Limitation class
      3
      [Ui] rated insulation voltage
      400 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      4 kV
      Surge current
      250 A
      Suitability for isolation
      yes
      Contact position indicator
      yes
      Control type
      toggle
      Local signalling
      ON/OFF indication
      Mounting mode
      clip-on
      Mounting support
      DIN rail
      Comb busbar and distribution block compatibility
      NO
      9 mm pitches
      4
      Height
      110 mm
      Width
      36 mm
      Depth
      75.5 mm
      Net weight
      332 g
      Mechanical durability
      20000 cycles
      Electrical durability
      5000 cycles
      Provision for padlocking
      padlockable with padlock Ø 4 mm
      Locking options description
      ON/OFF locking facilities
      Connections - terminals
    • screw clamp terminal (top) 1-25 mm² rigid without cable end
    • screw clamp terminal (top) 1-16 mm² flexible
    • screw clamp terminal (bottom) 1-16 mm² rigid without cable end
    • screw clamp terminal (bottom) 1-10 mm² flexible
      • Wire stripping length
      • power circuit: 13 mm for bottom connection
      • power circuit: 14 mm for top connection
        • Tightening torque
        • power circuit: 3.5-3.5 N.m top
        • power circuit: 2-2 N.m bottom
          • Earth-leakage protection
            integrated
            Standards
          • AS/NZS 61009.1
          • IEC 61009-1
          • IEC 61009-2-2
            • IP degree of protection
              IP20
              Tropicalisation
              2
              Relative humidity
              95-95 % at 55-55 °C
              Ambient air temperature for operation
              -15-60 °C
              Ambient air temperature for storage
              -40-85 °C
              Sustainable offer status
              Green Premium product
              REACh Regulation
              Free of Substances of Very High Concern above the threshold
              EU RoHS Directive
              Compliant
              Mercury free
              Yes
              RoHS exemption information
              Yes
              China RoHS Regulation
              Product out of China RoHS scope. Substance declaration for your information
              Environmental Disclosure
              ENVPEP121008EN
              Circularity Profile
              ENVEOLI121005EN
              WEEE
              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

              Documents & downloads

              hide show
              Filter items
              • All

              • CAD Files and Packs

              • Product Brochures

              • Technical Data Catalogues

              • Catalog Page

              • Technical Leaflet

              • Installation Instruction

              • End of Life Manual

              • Product Environmental

              • Specification for Tender

              • Declaration of Conformity

              • Certificates (MSDS)

              Frequently Asked Questions

              hide show

              What is the part number for 2 pole 16amp RCBO 2 modules wide?

              The part name is A9D11216

              What is the replacement part for a 26896 RCB?

              The replacement part is a A9D61820.
              A9D11220 is best solution
              A9D11820 is an alternative 1 pole wide but no Neutral switching
              A9D61820 is an alternative 1 pole wide but no Neutral switching and only 6kA
               

              What is the alternative to the 4RCBE210/30?

              Within the Schneider Electric range, the alternative for the 4RCBE210/30 is A9D11210

              What is the part number for an A9D11810 but in "D" curve?

              need to build up with "D" curve circuit breaker A9F55110 and vigi unit A9V02663
              for more details see ....... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F55110
              and ............... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9V02663
              User-added image    User-added image

              Does the A9D61816 RCBO have a neutral tail?

              Yes the A9D61816 and all that range have a neutral tail and also an Earth reference point.

              Does the A9D61816 RCBO have a neutral tail?

              Yes, the A9D61816 and all that range have a neutral tail and also an Earth reference point
              for more information see data sheet https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=a9d61816
              User-added image

              How wide is A9A15219 Safety Transformer ?

              10 Modules of 9mm = 90mm 

              What is the code for 10A 2P D Curve MCB - rated at 10kA ?

              Code = A9F45210   C60 MCB 

              What do I need to put together a single phase 30A 56 Series RCD

              Use 56CB4 + A9R51240 40amp RCCB

              What is the code of the Domae version of a 23358 40A 2p RCCB?

              It is a DOM16695

              Is the Acti 9 range of RCCB 120v ac rated?

              All Acti9 RCCB's are rated 230-240v AC only

              What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

               
               

              A9D33620 = SI (Super Immunised)
              A9D32620 = Type A (AC or pulsating DC)

              Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
              Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
               

              Can the A9F44210 be used with 110v AC?

              Yes it can, the only difference between a 100v and 230v is that you will get 36kA breaking capacity as opposed to 20kA (230v).



               

              ACDC1010 Hot Aisle Containment Rack Expansion Bundle Kit Installation (Manual)

              Issue:  ACDC1010 Hot Aisle Containment Rack Expansion Bundle Kit Installation (Manual)

               

              Product line: HACS

               

              Environment:  

               

               

              Cause:  Install, A Rack Expansion Bundle Kit is a complete set of racks, joining brackets, joining trim, hardware and ceiling panel required to extend an existing Hot Aisle Containment System.

                

               

              Resolution: 

               

              A Rack Expansion Bundle Kit is a complete set of racks, joining brackets, joining trim, hardware and ceiling panel required to extend an existing Hot Aisle Containment System.

               

               

              Ceiling panel assemblies come with Lexan® inserts that are not yet attached to the frames. Remove these and store them in a safe location until you begin the ceiling panel

              Installation process.

               

              Safety Instructions

               

              Potential electrical hazard exists when removing/installing side panels from a PDU, UPS, or XR Battery Cabinet. APC does not recommend performing any service to

              the PDU, UPS, or XR Battery Cabinet while it is energized. However, due to the critical nature of data center loads, this may occur. If you must perform this

              operation while the PDU, UPS, or XR Battery Cabinet is receiving input power, observe the following precautions to reduce the risk of electrical shock:

              1. Never work alone.

              2. Perform the work only if you are a certified electrician who is trained in the hazards of live electrical installation.

              3. Know the procedure for disconnecting electricity to the PDU, UPS, or XR Battery Cabinet, in case of an emergency.

              4. Wear appropriate personal protective equipment.

              5. Use double-insulated tools.

              6. Always follow local and site regulations when working on the PDU, UPS, or XR Battery Cabinet.

               

               

              Installation

               

              Each of the following procedures is required to correctly install your Rack Expansion Bundle Kit. Perform these procedures in this order.

               

              Side Panel Removal

               

              Remove the side panels at the end of the row of the Hot Aisle Containment System; each panel is connected by ground a strap that must be disconnected to completely remove each panel.

               

              Door and Door Frame Removal

               

              The door frame is heavy and requires at least two persons to safely remove and store it

               

              Remember to save all hardware that you remove so that it may be reused when you reinstall the door and door frame.

               

               

               

              5. Remove five M6×12 mm screws and M6 flange nuts on each doorframe upright to remove the door frame assembly from the equipment frames

               

              21U Side Panels

               

              Before attaching new racks to an existing system, install two 21 U side panels onto each NetShelter VS (900-mm) or NetShelter VX (1070-mm) enclosure. If grounding is required, there are two

              grounding studs on each 21U side panel.

               

               

              PSX/PDU side panel installation

               

              See the “Safety Instructions” on page 5 before installing any side panels on a PSX or PDU.

               

              IF you plan to install a Rack Expansion Bundle Kit next to a PDU or UPS, then a PSX/PDU side panel (ACDC1008, not included) must be installed on the PDU or UPS. A PSX/PDU side panel kit is

              available from APC. Attach the ground strap (previously removed from the side panel) to the new PSX/PDU side panel.

              Rear joining brackets for two 1070-mm enclosures

               

              When joining two NetShelter VX (1070-mm) enclosures:

               

              1. Remove the rear doors of the enclosures before you install the joining brackets.

               

               

              Rear joining brackets for two 1070-mm enclosures

               

              When joining two NetShelter VX (1070-mm) enclosures:

               

              1. Remove the rear doors of the enclosures before you install the joining brackets

               

              See the instructions included with your equipment to remove the rear doors.

               

              Do not remove the rear doors of the UPS, PDU, or XR Battery Cabinet

               

                    2. Use appropriate rear joining brackets. Orient the brackets so that the two round holes are at the top position, and the slots are located in the middle and lower positions. Use six M6 × 12-mm

              screws.

              Rear joining brackets and trim for 900-mm and 1070-mm enclosures

               

              When joining a NetShelter VS (900-mm) to a NetShelter VX (1070-mm) enclosure, use rear joining brackets and trim.

               

              Remove the rear doors of the enclosures before you install the joining brackets

               

              See the instructions included with your equipment to remove the rear doors

               

                               1. Attach two trim brackets to the side of the enclosure. Align each bracket’s mounting hole with the bottom hole of the top and bottom set of holes (as shown) in the enclosure.

                                   Use an M6 × 12-mm screw and a flange nut for each bracket. Use 1070-mm joining brackets for 1070-mm enclosures and 900-mm brackets for 900-mm enclosures.

               

               

              The use of the top or bottom hole depends on the placement of the enclosures.

              If the 900-mm and 1070-mm enclosures are switched (900-mm on the left and 1070-mm on the right), turn the 1070-mm joining bracket 180°, and attach it to the

              top hole of the 1070-mm enclosure. Turn the 900-mm joining bracket 180°, and attach it to the lower hole of the 900-mm enclosure. Finally, turn the the joining trim 180°

               

               

               

               

              Ceiling Panels

               

              Types of ceiling panels and required hardware

              The ceiling panels are configured in two different widths based on the size of the enclosures they span..

               

               

              Ceiling panels are not intended to support weight. Do not use ceiling panels to support power or data cables

               

              See the instructions that come with your equipment for proper installation of the ladders.

               

              Preparing for ceiling panel installation

               

              Install Plasti-Grommets into the tops of the equipment (two grommets per enclosure top).

               

               

              Ceiling panel installation

               

              1. Apply the ceiling panel gasket material to the edge of the ceiling panel that will face the door frame

               

               

              Ceiling panel inserts

               

              1. Remove the adhesive backing film from the panel frame; remove the protective plastic from both sides of the Lexan and carefully set the Lexan panel in place, pressing the edges firmly.

               

              2. Attach the next ceiling panel securely to the previously installed ceiling panel. Use five M6 × 30-mm screws, ceiling panel brackets, and threaded ceiling panel brackets to secure the

              panels at each connection point, as shown.

               

               

               

              Door Frame and Door Installation

               

              To attach the door frame to the end of the aisle:

              1. Attach the door frame assembly to the equipment frames. Use five M6 × 12-mm screws and M6 flange nuts on each upright.

               

               

               

              3. Attach the plinth blocks to the enclosures, using four M8 × 25-mm screws

               

               

              Side Panels

               

              Install the side panels at the ends of each row of the Hot Aisle Containment System.

               

              Grounding side panels

               

              Attach one end of a ground strap to the grounding stud on each panel, and then attach the other end of the grounding strap to a grounding stud on the enclosure.

              APC offers an optional grounding kit (AR8390) for grounding an enclosure. na1334a

              See also

              See the instructions included with your new equipment for information on installation, joining, side panel placement, and grounding stud locations

               

              APC offers an optional grounding kit (AR8390) for grounding an enclosure

               

              Data Troughs

               

              Troughs are supplied separately from the Rack Expansion Bundle Kit.

               

              Install the troughs into the slots located in the ceiling panel frames.

               

              See the instructions supplied with the troughs.