iETL16A extension for impulse relay 1NO

Acti9 Extension iETL iTL 16, 1C/O+1NO, 16A, Coil 110VDC, 230...240V AC, 50/60Hz

Catalogue Number: A9C32816
iETL16A extension for impulse relay 1NO
Retail
$229.30
RRP (Inc. GST)

Specifications

hide show
Range of product
iTL
Range
Acti 9
Product or component type
extension for impulse relay
Device short name
iETL iTL 16
Relay application
remote control
Poles description
2P
Pole contact composition
1 C/O + 1 NO
[In] rated current
16 A
Network type
AC
Network frequency
50/60 Hz
[Ue] rated operational voltage
415 V AC 50/60 Hz
Control type
  • toggle
  • remote control
    • Control signal type
      impulse
      Switching frequency
      5 switching operations/minute
      Impulse duration
      50 ms
      Remote control type
      illuminated push-button 3 mA
      Local signalling
      ON/OFF indication
      [Uc] control circuit voltage
    • 230...240 V AC 50/60 Hz
    • 110 V DC
      • Supply inrush power
        19 VA
        Mounting mode
        fixed, on right side of TL
        Mounting support
        35 mm symmetrical DIN rail
        9 mm pitches
        2
        Height
        60 mm
        Width
        18 mm
        Depth
        84 mm
        Electrical durability
      • AC-21: 200000 cycles
      • AC-22: 100000 cycles
        • Connections - terminals
          tunnel type terminals - <= 6 mm²
          Auxiliary connection terminal
          tunnel type terminalscontrol circuit in 0.5-6 mm²
          Range compatibility
        • Acti 9 iTL iTL
        • Acti 9 iTL iTLi
          • Product compatibility
            iTL 16A
            Market segment
          • small commercial
          • residential
            • Compatibility code
              iETL iTL 16
              Standards
            • EN 669-1
            • EN 669-2-2
              • Product certifications
                GOST
                Quality labels
              • NF
              • VDE
              • CEBEC
              • KEMA
              • IMQ
                • Noise level
                  60 dB
                  IP degree of protection
                  IP20 conforming to IEC 60529
                  Pollution degree
                  3
                  Tropicalisation
                  2 conforming to IEC 60068-1
                  Relative humidity
                  95-95 % at 55-55 °C
                  Ambient air temperature for operation
                  -20-50 °C
                  Ambient air temperature for storage
                  -40-70 °C
                  Unit Type of Package 1
                  PCE
                  Number of Units in Package 1
                  1
                  Package 1 Weight
                  124 g
                  Package 1 Height
                  8 cm
                  Package 1 width
                  3 cm
                  Package 1 Length
                  9.3 cm
                  Unit Type of Package 2
                  BB1
                  Number of Units in Package 2
                  8
                  Package 2 Weight
                  1.044 kg
                  Package 2 Height
                  8.5 cm
                  Package 2 width
                  10 cm
                  Package 2 Length
                  26.5 cm
                  Unit Type of Package 3
                  S03
                  Number of Units in Package 3
                  72
                  Package 3 Weight
                  9.882 kg
                  Package 3 Height
                  30 cm
                  Package 3 width
                  30 cm
                  Package 3 Length
                  40 cm
                  Sustainable offer status
                  Green Premium product
                  REACh free of SVHC
                  Yes
                  EU RoHS Directive
                  Compliant
                  Mercury free
                  Yes
                  RoHS exemption information
                  Yes
                  China RoHS Regulation
                  Product out of China RoHS scope. Substance declaration for your information
                  Environmental Disclosure
                  ENVPEP110302EN
                  WEEE
                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                  Warranty
                  18 months

                  Frequently Asked Questions

                  hide show

                  What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

                   
                   

                  A9D33620 = SI (Super Immunised)
                  A9D32620 = Type A (AC or pulsating DC)

                  Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
                  Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
                   

                  Does the A9D61816 RCBO have a neutral tail?

                  Yes the A9D61816 and all that range have a neutral tail and also an Earth reference point.

                  Does the A9D61816 RCBO have a neutral tail?

                  Yes, the A9D61816 and all that range have a neutral tail and also an Earth reference point
                  for more information see data sheet https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=a9d61816
                  User-added image

                  What is the acti 9 equivelant of the 15512

                  The part code is A9C30211

                  what is the Acti 9 code for Merlin Gerin 15515?

                  A9C30831 is the Acti9 code for the 1P 1NO 32A 230v AC impulse relay.

                  Missing Kirk Key, how do I order replacement key?

                   
                   
                  Issue:
                  Missing Kirk Key, how do I order replacement key?
                   

                  Product line:
                  All Models
                   

                  Environment:
                  All Models,
                   

                  Cause:
                  Kirk Key missing or Broken
                   

                  Resolution:
                  Please find attached files for Duplicate Key Ordering Instructions- dupe key form.

                   

                   

                  Will the Compact NSX breaker be for sale in the USA or Canada?

                  Issue:
                  Where can I buy a Compact NSX breaker?

                  Product Line:
                  Circuit Breakers

                  Cause:
                  This breaker is popular overseas and there is interest in the US

                  Resolution:
                  There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

                  If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

                  For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
                  https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page