Quantcast

Acti9 Impulse Relay iTL, 1P, 1NO, 16A, Coil 130VAC, 50/60Hz, 48VDC

Acti9 Impulse Relay iTL, 1P, 1NO, 16A, Coil 130VAC, 50/60Hz, 48VDC

Acti9 Impulse Relay iTL, 1P, 1NO, 16A, Coil 130VAC, 50/60Hz, 48VDC

Item Number: A9C30311

Retail
$166.83
RRP (Inc. GST)

Product Dimensions

Width icon

Width18 mm

Height icon

Height84 mm

Depth icon

Depth60 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

iTL

Range

Acti 9

Product or component type

impulse relay

Device application

standard

Market segment

  • small commercial
  • residential
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      [In] rated current

      16 A

      [Ue] rated operational voltage

      250 V AC 50/60 Hz

      Control type

    • remote and manual control
    • coil deconnection
      • Control signal type

        impulse

        Remote control type

        illuminated push-button 3 mA

        Local signalling

        ON/OFF indication

        Mounting mode

        fixed

        Mounting support

        DIN rail

        Height

        84 mm

        Width

        18 mm

        Depth

        60 mm

        Electrical durability

      • AC-21: 200000 cycles
      • AC-22: 100000 cycles
        • Connections - terminals

        • control circuit: tunnel type terminals 1 cable(s) 0.5-4 mm² rigid
        • control circuit: tunnel type terminals 1 cable(s) 0.5-4 mm² rigid with cable end
        • control circuit: tunnel type terminals 1 cable(s) 1-4 mm² flexible
        • control circuit: tunnel type terminals 1 cable(s) 1-4 mm² flexible with ferrule
        • power circuit: tunnel type terminals 1 cable(s) 1.5-4 mm² rigid
        • power circuit: tunnel type terminals 1 cable(s) 1.5-4 mm² rigid with cable end
        • power circuit: tunnel type terminals 1 cable(s) 1.5-4 mm² flexible
        • power circuit: tunnel type terminals 1 cable(s) 1.5-4 mm² flexible with ferrule
          • Wire stripping length

            11 mm

            Range compatibility

          • iATEt
          • iATLc
          • iATLc+s
          • iATLm
          • iATLs
          • iETL iTL 16
          • iATLc+c
            • Standards

            • EN 669-1
            • EN 669-2-2
              • Product certifications

                GOST

                IP degree of protection

              • IP20 conforming to IEC 60529 (on opening)
              • IP40 conforming to IEC 60529 (in enclosure)
                • Relative humidity

                  95-95 % at 55-55 °C

                  Ambient air temperature for operation

                  -20-50 °C

                  Ambient air temperature for storage

                  -40-70 °C

                  REACh free of SVHC

                  Yes

                  EU RoHS Directive

                  Compliant

                  Mercury free

                  Yes

                  RoHS exemption information

                  Yes

                  China RoHS Regulation

                  Product out of China RoHS scope. Substance declaration for your information

                  Environmental Disclosure

                  ENVPEP110302EN

                  Others

                  Product name

                  Acti 9 iTL

                  Device short name

                  iTL

                  Poles description

                  1P

                  Pole contact composition

                  1 NO

                  Network type

                  AC

                  [Uc] control circuit voltage

                • 130 V AC 50/60 Hz
                • 48 V DC
                  • Network frequency

                    50/60 Hz

                    Switching frequency

                  • 5 switching operations/minute
                  • 100 switching operations/day
                    • Impulse duration

                      50 ms...1 s

                      9 mm pitches

                      2

                      Tightening torque

                      1-1 N.m

                      Compatibility code

                      iTL

                      Quality labels

                    • KEMA
                    • VDE
                    • IMQ
                    • CEBEC
                    • NF
                      • Noise level

                        60 dB

                        Pollution degree

                        3

                        Tropicalisation

                        2

                        Unit Type of Package 1

                        PCE

                        Number of Units in Package 1

                        1

                        Package 1 Weight

                        105 g

                        Package 1 Height

                        1.8 cm

                        Package 1 width

                        7 cm

                        Package 1 Length

                        8.5 cm

                        Unit Type of Package 2

                        BB1

                        Number of Units in Package 2

                        12

                        Package 2 Weight

                        1.313 kg

                        Package 2 Height

                        9 cm

                        Package 2 width

                        8 cm

                        Package 2 Length

                        23 cm

                        Unit Type of Package 3

                        S03

                        Number of Units in Package 3

                        144

                        Package 3 Weight

                        16.298 kg

                        Package 3 Height

                        30 cm

                        Package 3 width

                        30 cm

                        Package 3 Length

                        40 cm

                        WEEE

                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                        Show all specifications

                        Frequently Asked Questions

                        hide show

                        What is the acti 9 equivelant of the 15512

                        The part code is A9C30211

                        what is the Acti 9 code for Merlin Gerin 15515?

                        A9C30831 is the Acti9 code for the 1P 1NO 32A 230v AC impulse relay.

                        Is the 15958 classed as a double pole

                         No - The 15958 only is 1 NO contact

                        New code for 15958?

                        New code is
                        A9C20731

                        Is there an iCT contactor available above 100Amp?

                        No, The largest current rating we have available in the iCT contactors is 100A. For Higher currents see the TeSys D product.

                        https://www.schneider-electric.com/en/product-range/664-tesys-d/

                         

                        How can I control an ATV61/71 via the Modbus communication channel?

                        Issue:
                        Control an ATV61/71 via the Modbus channel.

                        Product Line:
                        Altivar 61, Altivar 71

                        Environment:
                        All

                        Cause:
                        Programming

                        Resolution:
                        To control the ATV61/71 via the Modbus RTU communication channel, it is first necessary to configure the modbus communication parameters.

                        In the ATV61/71 Communications menu, go into MODBUS NETWORK submenu.

                        Parameter Add (Modbus Address) is adjustable between OFF to 247.
                        Parameter TBR (Modbus baud rate) is adjustable from 4.8-38400 bauds.
                        4.8K
                        9.6K
                        19.2K
                        38.4K

                        Parameter TFO (Modbus format) is adjustable from 8-odd-1, 8-even-1, 8-neutral-1, and 8-netural-2.
                        8O1 = 8 data bits, odd parity, 1 stop bit
                        8E1 = 8 data bits, even parity, 1 stop bit
                        8n1 = 8 data bits, no parity, 1 stop bit
                        8n2 = 8 data bits, no parity, 2 stop bit

                        Parameter TTO is the modbus timeout value adjustable from .1 to 30 seconds.

                        Please note that these settings are not stored until the ATV61/71 power supply is switched off and on again.
                        Next, configure the command and reference channels. The Command channel is the channel which provides the ATV61/71 with signals to start and stop, the Reference channel provides the motor speed reference. 

                        These two items can be separated in terms of how they are programmed in the Command menu, as shown in the following examples;
                        Example 1
                        Both the command and reference come from the Modbus communication channel. 
                        CtL Command menu => Reference 1 configuration: Fr1 = Reference via Modbus.
                        CtL Command menu => Profile not separate. 

                        Example 2
                        The command channel is separate from the reference channel. The speed reference is sent via modbus, control can be via the terminals, display terminal, etc.
                        CtL Command menu => Reference 1 configuration: Fr1 = Mdb: Reference via Modbus.
                        CtL Command menu => Mixed mode: profile SEP: Profile separate.
                        CtL Command menu => Cd1: Command channel 1:  Configuration of command channel is selected from the following;
                        Terminals, HMI, Modbus, Com card, Prog. card.

                        Example 3
                        The command channel is separate from the reference channel. Only the command is via Modbus:
                        CtL Command menu => Reference 1 configuration: Fr1 is selected from the following options;

                        AI1: Analog input AI1
                        AI2: Analog input AI2
                        AI3: Analog input AI3
                        AI4: Analog input AI4
                        LCC: HMI
                        NDB: Modbus
                        CAN: Canopen
                        NET: Com. card
                        APP: Prog card
                        P1: RP
                        PG: Encoder

                         
                        CtL Command menu => Profile separate.
                        CtL Command menu => Cd1: Configuration of command channel = Mdb Command via Modbus network 
                        This completes the configuration changes required within the ATV61/71 to implement modbus control. The controlling PLC will require appropriate programming to ensure that the correct sequence of instructions is sent to the ATV61/71 to achieve the required functionality.

                        Profile as I/O profile allows the first bit in the command word register 8501 to be a run forward.
                        The rest of the bits of the command word is programmed as seen fit.  
                        For further information, refer to the following manuals;
                        Show More