iTL 16A impulse relay 1NO

Acti9 Impulse Relay iTL, 1P, 1NO, 16A, Coil 130VAC, 50/60Hz, 48VDC

Catalogue Number: A9C30311
iTL 16A impulse relay 1NO
Retail
$166.83
RRP (Inc. GST)

Specifications

hide show
Range of product
iTL
Range
Acti 9
Product name
Acti 9 iTL
Product or component type
impulse relay
Device short name
iTL
Device application
standard
Poles description
1P
Pole contact composition
1 NO
[In] rated current
16 A
Network type
AC
[Uc] control circuit voltage
  • 130 V AC 50/60 Hz
  • 48 V DC
    • Network frequency
      50/60 Hz
      [Ue] rated operational voltage
      250 V AC 50/60 Hz
      Control type
    • remote and manual control
    • coil deconnection
      • Control signal type
        impulse
        Switching frequency
      • 5 switching operations/minute
      • 100 switching operations/day
        • Impulse duration
          50 ms...1 s
          Remote control type
          illuminated push-button 3 mA
          Local signalling
          ON/OFF indication
          Mounting mode
          fixed
          Mounting support
          DIN rail
          9 mm pitches
          2
          Height
          84 mm
          Width
          18 mm
          Depth
          60 mm
          Electrical durability
        • AC-21: 200000 cycles
        • AC-22: 100000 cycles
          • Connections - terminals
          • control circuit: tunnel type terminals 1 cable(s) 0.5-4 mm² rigid
          • control circuit: tunnel type terminals 1 cable(s) 0.5-4 mm² rigid with cable end
          • control circuit: tunnel type terminals 1 cable(s) 1-4 mm² flexible
          • control circuit: tunnel type terminals 1 cable(s) 1-4 mm² flexible with ferrule
          • power circuit: tunnel type terminals 1 cable(s) 1.5-4 mm² rigid
          • power circuit: tunnel type terminals 1 cable(s) 1.5-4 mm² rigid with cable end
          • power circuit: tunnel type terminals 1 cable(s) 1.5-4 mm² flexible
          • power circuit: tunnel type terminals 1 cable(s) 1.5-4 mm² flexible with ferrule
            • Wire stripping length
              11 mm
              Tightening torque
              1-1 N.m
              Range compatibility
            • iATEt
            • iATLc
            • iATLc+s
            • iATLm
            • iATLs
            • iETL iTL 16
            • iATLc+c
              • Market segment
              • small commercial
              • residential
                • Compatibility code
                  iTL
                  Standards
                • EN 669-1
                • EN 669-2-2
                  • Product certifications
                    GOST
                    Quality labels
                  • KEMA
                  • VDE
                  • IMQ
                  • CEBEC
                  • NF
                    • Noise level
                      60 dB
                      IP degree of protection
                    • IP20 conforming to IEC 60529 (on opening)
                    • IP40 conforming to IEC 60529 (in enclosure)
                      • Pollution degree
                        3
                        Tropicalisation
                        2
                        Relative humidity
                        95-95 % at 55-55 °C
                        Ambient air temperature for operation
                        -20-50 °C
                        Ambient air temperature for storage
                        -40-70 °C
                        Unit Type of Package 1
                        PCE
                        Number of Units in Package 1
                        1
                        Package 1 Weight
                        105 g
                        Package 1 Height
                        1.8 cm
                        Package 1 width
                        7 cm
                        Package 1 Length
                        8.5 cm
                        Unit Type of Package 2
                        BB1
                        Number of Units in Package 2
                        12
                        Package 2 Weight
                        1.313 kg
                        Package 2 Height
                        9 cm
                        Package 2 width
                        8 cm
                        Package 2 Length
                        23 cm
                        Unit Type of Package 3
                        S03
                        Number of Units in Package 3
                        144
                        Package 3 Weight
                        16.298 kg
                        Package 3 Height
                        30 cm
                        Package 3 width
                        30 cm
                        Package 3 Length
                        40 cm
                        Sustainable offer status
                        Green Premium product
                        REACh free of SVHC
                        Yes
                        EU RoHS Directive
                        Compliant
                        Mercury free
                        Yes
                        RoHS exemption information
                        Yes
                        China RoHS Regulation
                        Product out of China RoHS scope. Substance declaration for your information
                        Environmental Disclosure
                        ENVPEP110302EN
                        WEEE
                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                        Warranty
                        18 months

                        Frequently Asked Questions

                        hide show

                        What is the acti 9 equivelant of the 15512

                        The part code is A9C30211

                        what is the Acti 9 code for Merlin Gerin 15515?

                        A9C30831 is the Acti9 code for the 1P 1NO 32A 230v AC impulse relay.

                        Is the 15958 classed as a double pole

                         No - The 15958 only is 1 NO contact

                        New code for 15958?

                        New code is
                        A9C20731

                        Is there an iCT contactor available above 100Amp?

                        No, The largest current rating we have available in the iCT contactors is 100A. For Higher currents see the TeSys D product.

                        https://www.schneider-electric.com/en/product-range/664-tesys-d/

                         

                        How can I control an ATV61/71 via the Modbus communication channel?

                        Issue:
                        How can I control an ATV61/71 via the Modbus communication channel?

                        Product Line:
                        Altivar 61, Altivar 71

                        Environment:
                        All

                        Cause:
                        Programming

                        Resolution:
                        To control the ATV61/71 via the Modbus RTU communication channel, it is first necessary to configure the modbus communication parameters.

                        In the ATV61/71 Communications menu, go into MODBUS NETWORK submenu.

                        Parameter Add (Modbus Address) is adjustable between OFF to 247.
                        Parameter TBR (Modbus baud rate) is adjustable from 4.8-38400 bauds.
                        4.8K
                        9.6K
                        19.2K
                        38.4K

                        Parameter TFO (Modbus format) is adjustable from 8-odd-1, 8-even-1, 8-neutral-1, and 8-netural-2.
                        8O1 = 8 data bits, odd parity, 1 stop bit
                        8E1 = 8 data bits, even parity, 1 stop bit
                        8n1 = 8 data bits, no parity, 1 stop bit
                        8n2 = 8 data bits, no parity, 2 stop bit

                        Parameter TTO is the modbus timeout value adjustable from .1 to 30 seconds.

                        Please note that these settings are not stored until the ATV61/71 power supply is switched off and on again.
                        Next, configure the command and reference channels. The Command channel is the channel which provides the ATV61/71 with signals to start and stop, the Reference channel provides the motor speed reference. 

                        These two items can be separated in terms of how they are programmed in the Command menu, as shown in the following examples;
                        Example 1
                        Both the command and reference come from the Modbus communication channel. 
                        CtL Command menu => Reference 1 configuration: Fr1 = Reference via Modbus.
                        CtL Command menu => Profile not separate. 

                        Example 2
                        The command channel is separate from the reference channel. The speed reference is sent via modbus, control can be via the terminals, display terminal, etc.
                        CtL Command menu => Reference 1 configuration: Fr1 = Mdb: Reference via Modbus.
                        CtL Command menu => Mixed mode: profile SEP: Profile separate.
                        CtL Command menu => Cd1: Command channel 1:  Configuration of command channel is selected from the following;
                        Terminals, HMI, Modbus, Com card, Prog. card.

                        Example 3
                        The command channel is separate from the reference channel. Only the command is via Modbus:
                        CtL Command menu => Reference 1 configuration: Fr1 is selected from the following options;

                        AI1: Analog input AI1
                        AI2: Analog input AI2
                        AI3: Analog input AI3
                        AI4: Analog input AI4
                        LCC: HMI
                        NDB: Modbus
                        CAN: Canopen
                        NET: Com. card
                        APP: Prog card
                        P1: RP
                        PG: Encoder

                         
                        CtL Command menu => Profile separate.
                        CtL Command menu => Cd1: Configuration of command channel = Mdb Command via Modbus network 
                        This completes the configuration changes required within the ATV61/71 to implement modbus control. The controlling PLC will require appropriate programming to ensure that the correct sequence of instructions is sent to the ATV61/71 to achieve the required functionality.

                        Profile as I/O profile allows the first bit in the command word register 8501 to be a run forward.
                        The rest of the bits of the command word is programmed as seen fit.  
                        For further information, refer to the following manuals;

                        Will the Compact NSX breaker be for sale in the USA or Canada?

                        Issue:
                        Where can I buy a Compact NSX breaker?

                        Product Line:
                        Circuit Breakers

                        Cause:
                        This breaker is popular overseas and there is interest in the US

                        Resolution:
                        There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

                        If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

                        For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
                        https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page