Acti9 Iacts 1No-1Nc, 2A, Indication, Auxiliary Contact

Acti9 Iacts 1No-1Nc, 2A, Indication, Auxiliary Contact

Acti9 Iacts 1No-1Nc, 2A, Indication, Auxiliary Contact

Item Number: A9C15914

Retail
$168.45
RRP (Inc. GST)

Product Dimensions

Width icon

Width9 mm

Height icon

Height81 mm

Depth icon

Depth68 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

iCT

Range

Acti 9

Product or component type

remote indication auxiliary

Product compatibility

iCT

Market segment

  • small commercial
  • residential
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Range compatibility

      Acti 9 iCT

      Mounting mode

      fixed, on the right of CT

      Mounting support

      35 mm symmetrical DIN rail

      Height

      81 mm

      Width

      9 mm

      Depth

      68 mm

      Wire stripping length

      9 mm

      Standards

      EN 60947-5

      IP degree of protection

    • IP20
    • IP20 conforming to IEC 60529
      • Relative humidity

        95-95 % at 55-55 °C

        Ambient air temperature for operation

        -5-50 °C

        Ambient air temperature for storage

        -40-70 °C

        REACh free of SVHC

        Yes

        EU RoHS Directive

        Compliant

        Toxic heavy metal free

        Yes

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

        X

        Environmental Disclosure

        ENVPEP110308EN

        Others

        Device short name

        iACTs

        Signal contacts composition

        1 NO + 1 NC

        Signalling circuit voltage

      • 24 V AC/DC: 10 mA
      • 230 V AC: 50/60 Hz 5 A
      • 230 V AC: 50/60 Hz 2 A
      • 130 V DC: 1 A
        • [Uc] control circuit voltage

        • 24...240 V AC 50/60 Hz
        • 24...130 V DC
          • [Ui] rated insulation voltage

            440 V

            [Uimp] rated impulse withstand voltage

            4 kV

            9 mm pitches

            1

            Auxiliary connection terminal

          • tunnel type terminals2 cable(s) flexible 2.5-2.5 mm²
          • tunnel type terminals2 cable(s) rigid 1.5-1.5 mm²
          • tunnel type terminals1 cable(s) rigid 1.5-2.5 mm²
          • tunnel type terminals1 cable(s) flexible 1.5-2.5 mm²
            • Tightening torque

              0.8-0.8 N.m

              Compatibility code

              iACTs

              Tropicalisation

              2

              Unit Type of Package 1

              PCE

              Number of Units in Package 1

              1

              Package 1 Weight

              44 g

              Package 1 Height

              2.2 cm

              Package 1 width

              7.5 cm

              Package 1 Length

              8.5 cm

              Unit Type of Package 2

              BB1

              Number of Units in Package 2

              10

              Package 2 Weight

              503 g

              Package 2 Height

              9 cm

              Package 2 width

              8 cm

              Package 2 Length

              23 cm

              Unit Type of Package 3

              S03

              Number of Units in Package 3

              120

              Package 3 Weight

              6.273 kg

              Package 3 Height

              30 cm

              Package 3 width

              30 cm

              Package 3 Length

              40 cm

              WEEE

              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
              Show all specifications

              Frequently Asked Questions

              hide show

              What is the Alternative for the Merlin Gerin 15913?

              A9C15913

              What is the dimensions of the load shedding device A9C15906 ?

              Height = 77 mm  Width = 145 mm Depth = 60 mm

              How wide is A9A15219 Safety Transformer ?

              10 Modules of 9mm = 90mm 

              Is technical support or drivers available for 19018, APC-4914 or APC-7314?

              Issue:
              Technical support is required.

              Product Line:
              Cables and Connectivity Solutions

              Environment:
              USB Extender, USB File Transfer Cable

              Cause:
              Need drivers or other technical support.

              Resolution:
              For technical support please contact APC Cables. 
              Phone: 888-370-6688 in North America.
              email: support@apccables.com

              Driver download for 19018, APC-4914 and APC-7314
              Please go to ftp://apccables.com/driver
              User Name: Top61_PC
              Password: Top61_PC
              For the APC-4914 choose model BF-4914
              For the APC-7314 choose model BF-7314
              For the 19018 choose model BF-320

              What is the part number for the auxiliary for A9C20843 contactor?

              The part number for the auxiliary for A9C20843 contactor is A9C15914
              For further information see:https://eshop.schneider-electric.com/product.aspx?prod_id=A9C15914&org=21&lang=1&dist=276&tab=0&ses_id=
               

              what is the maximum current for the R2 relay contacts on all sizes of ATS48 range of soft start

              Goals and Symptoms

              what is the maximum current for the R2 relay contacts on all sizes of ATS48 range of soft start

              Facts and Changes

              maximum current
              R2 relay
              soft start

              Causes and Fixes


              Characteristics of ATS48 relay :
              max voltage : 400Vac (0.2A max)
              thermal current : 5A
              During life :
              AC load
              AC1 5A 250V 10E5 cycles (resistor)
              AC15-14 : 0.5A (240Vac) 10E6 cycles (contactor)
              Cos 0.5 1.8A (240Vac) 10E5 cycles (inductive)

              DC load
              DC13 : 0.5A (48Vdc) 10E6 cycles (contactor)
              L/R 20mS 1.8A (30Vdc) 10E5 cycles (inductive)
              minima commutation capacities :
              6Vdc 10mA 10E7 cycles (PLC low level)

              It's availble for all range.