Quantcast

Acti9 Voltage Release, iMX+OF, Tripping Unit, 12..24VAC, Shunt Rel

Acti9 Voltage Release, iMX+OF, Tripping Unit, 12..24VAC, Shunt Rel

Acti9 Voltage Release, iMX+OF, Tripping Unit, 12..24VAC, Shunt Rel

Item Number: A9A26948

Retail
$401.54
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Acti 9

Product or component type

shunt trip release with OC contact

Range of product

  • iSW-NA
  • iID
  • iDPN Vigi
  • iC60
    • Product compatibility

    • single terminal
    • iID
    • iC60
    • double terminal
    • iDPN Vigi
    • RCA
    • ARA
    • iSW-NA
      • Market segment

      • residential
      • small commercial
        • Sustainable offer status

          Green Premium product

          Warranty

          18 months

          Physical

          [Ie] rated operational current

        • AC-12: 6 A at 12 V AC 50 Hz
        • AC-12: 6 A at 24 V AC 50 Hz
        • DC-12: 6 A at 12 V DC
        • DC-12: 6 A at 24 V DC
          • Range compatibility

          • Acti 9 iC65
          • Acti 9 ARA
          • Acti 9 iDPN Vigi
          • Acti 9 iID
          • Acti 9 iSW-NA
          • Acti 9 RCA
          • Acti 9 iDPN (China version)
          • Acti 9 iC60 double terminals miniature circuit breaker
          • Acti 9 iC40
            • Local signalling

              action indicator

              Mounting mode

              clip-on

              Mounting support

              DIN rail

              Width

              18 mm

              Connections - terminals

            • clamp terminal - 2 cable(s) 2.5-2.5 mm² - flexible with cable end
            • clamp terminal - 1 cable(s) 6-6 mm² - rigid
            • clamp terminal - 2 cable(s) 2.5-2.5 mm² - rigid
            • clamp terminal - 1 cable(s) 4-4 mm² - flexible
              • Standards

                EN/IEC 60947-5-1

                Relative humidity

                95-95 % at 55-55 °C

                Ambient air temperature for operation

                -25-50 °C

                Ambient air temperature for storage

                -40-85 °C

                REACh free of SVHC

                Yes

                EU RoHS Directive

                Compliant

                Toxic heavy metal free

                Yes

                Mercury free

                Yes

                RoHS exemption information

                Yes

                China RoHS Regulation

                 Pro-active China RoHS declaration (out of China RoHS legal scope)

                Environmental Disclosure

                ENVPEP1305024

                Others

                Device short name

                iMX+OF

                Signal contacts composition

                1 C/O

                [Uc] control circuit voltage

              • 12...24 V AC 50/60 Hz
              • 12...24 V DC
                • 9 mm pitches

                  2

                  Tightening torque

                  1-1 N.m

                  Compatibility code

                  iMX+OF

                  Tropicalisation

                  2 conforming to EN/IEC 60947-5-1

                  Package 1 Weight

                  0.083 kg

                  Package 1 Height

                  0.77 dm

                  Package 1 width

                  0.8 dm

                  Package 1 Length

                  0.95 dm

                  WEEE

                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                  Show all specifications

                  Frequently Asked Questions

                  hide show

                  Will a new A9A26948 fit an old MG breaker

                  No they don't fit. You will need to replace the old MG MCB with new Acti9 MCB to fit the new Auxiliaries

                  will the A9A26929 fit on a C60-DC MCB?

                  No, those are designed to fit onto the acti9 AC MCBs for those MCBs use the A9N26929

                  What are the codes of the items supplied with the 3 phase EV parking protection kits?

                  Parts that should be supplied as follows:

                  KITPARKING22-1:
                  A9F54440 x 1, MCB, iC60H 4P 40A C Curve
                  A9Z51440 x 1, RCD, iIDP 4P 40A 30mA Type B, 400V
                  A9A26969 x 2, Under voltage release, iMNX 220 240VAC
                  A9F44204 x 1, MCB, iC60N 2P 4A C Curve
                  A9R91240 x 1, RCCB, iID 2P 40A 30mA Type Asi
                  A9A26924 x 2, Aux contact, iOF 240 415VAC 24 130VDC

                  KITPARKING22-2:
                  A9F54440 x 2, MCB, iC60H 4P 40A C Curve
                  A9Z51440 x 2, RCD, iIDP 4P 40A 30mA Type B, 400V
                  A9A26969 x 3, Under voltage release, iMNX 220 240VAC
                  A9F44204 x 1, MCB, iC60N 2P 4A C Curve
                  A9R91240 x 1, RCCB, iID 2P 40A 30mA Type Asi
                  A9A26924 x 4, Aux contact, iOF 240 415VAC 24 130VDC
                   

                  What is the code for the Acti9 Padlock?

                  The code is A9A26970

                  Are the A9N18359 and A9A26924 compatible?

                  The ref A9N18359 is C120 MCB (Multi9 design in the white material).

                  The ref A9A26924 is iOF auxiliary (Aciti9 design for iC60 MCB).

                  I can confirm that the parts A9N18359 and A9A26924 are not compliant with each other

                   

                  Does A9A26976 go with iDPN N VIGI?

                  No. Unfortunately it does not and we don't do the terminal Shiels for iDPN N vigi as the screws are small.
                  Show More