61011_A9A26924
iOF Auxiliary contact
61011_A9A26924
iOF Auxiliary contact

Acti 9 Auxiliary Contact Iof, 1 Change Over, 240-415VAC, 24-130VDC

Catalogue Number: A9A26924
61011_A9A26924
iOF Auxiliary contact
61011_A9A26924
iOF Auxiliary contact
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Acti 9
Range of product
  • iID
  • ARA
  • iSW-NA
  • RCA
  • iSW 40...125
  • iC60
  • iDPN Vigi
    • Product or component type
      OC contact
      Device short name
      iOF
      Signal contacts composition
      1 C/O
      [In] rated current
    • 1-1 A at 130 V DC
    • 1.5-1.5 A at 60 V DC
    • 2-2 A at 48 V DC
    • 6-6 A at 24 V DC
    • 3-3 A at 415 V AC - 50/60 Hz
    • 6-6 A at 240 V AC - 50/60 Hz
      • 9 mm pitches
        1
        Range compatibility
      • Acti 9 iSW-NA
      • Acti 9 iC60
      • Acti 9 iC65
      • Acti 9 iC60 RCBO
      • Acti 9 iID
      • Acti 9 ARA
      • Acti 9 RCA
      • Acti 9 iDPN (China version)
      • Acti 9 iDPN Vigi
      • Acti 9 iSW
      • Acti 9 iC40
        • [Ui] rated insulation voltage
          500 V
          [Uimp] rated impulse withstand voltage
          4 kV
          Mounting mode
          clip-on
          Mounting support
          DIN rail
          Height
          86 mm
          Width
          9 mm
          Depth
          73 mm
          Net weight
          32 g
          Connections - terminals
        • screw clamp terminal (bottom) 1 cable(s) 1-4 mm² - rigid
        • screw clamp terminal (bottom) 1 cable(s) 0.5-2.5 mm² - flexible
        • screw clamp terminal (bottom) 2 cable(s) 2.5-2.5 mm² - rigid
        • screw clamp terminal (bottom) 2 cable(s) 1.5-1.5 mm² - flexible with ferrule
          • Wire stripping length
            10 mm
            Tightening torque
            1-1 N.m
            Product compatibility
            single terminal
            Compatibility code
            iOF
            Market segment
          • small commercial
          • residential
            • Standards
              EN/IEC 60947-5-1
              IP degree of protection
              IP20 conforming to EN/IEC 60947-5-1
              Pollution degree
              3 conforming to EN/IEC 60947-5-1
              Tropicalisation
              2 conforming to EN/IEC 60947-5-1
              Ambient air temperature for operation
              -35-70 °C
              Ambient air temperature for storage
              -40-85 °C
              Sustainable offer status
              Green Premium product
              REACh Regulation
              Free of Substances of Very High Concern above the threshold
              REACh free of SVHC
              Yes
              EU RoHS Directive
              Compliant
              Toxic heavy metal free
              Yes
              Mercury free
              Yes
              RoHS exemption information
              Yes
              China RoHS Regulation
               Pro-active China RoHS declaration (out of China RoHS legal scope)
              Environmental Disclosure
              ENVPEP091004EN
              Circularity Profile
              ENVEOLI100608EN
              WEEE
              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
              Warranty
              18 months

              Documents & downloads

              hide show
              Filter items
              • All

              • Product Brochures

              • CAD Files and Packs

              • Technical Data Catalogues

              • End of Life Manual

              • Product Environmental

              • Installation Instruction

              • Declaration of Conformity

              Frequently Asked Questions

              hide show

              Are the A9N18359 and A9A26924 compatible?

              The ref A9N18359 is C120 MCB (Multi9 design in the white material).

              The ref A9A26924 is iOF auxiliary (Aciti9 design for iC60 MCB).

              I can confirm that the parts A9N18359 and A9A26924 are not compliant with each other

               

              will the A9A26929 fit on a C60-DC MCB?

              No, those are designed to fit onto the acti9 AC MCBs for those MCBs use the A9N26929

              What is the code for the Acti9 Padlock?

              The code is A9A26970

              Will a new A9A26948 fit an old MG breaker

              No they don't fit. You will need to replace the old MG MCB with new Acti9 MCB to fit the new Auxiliaries

              Does A9A26976 go with iDPN N VIGI?

              No. Unfortunately it does not and we don't do the terminal Shiels for iDPN N vigi as the screws are small.

              Padlocking device to fit Domae MCB

              the Acti9 A9A26970 will fit on the domae breakers.

              Does the A9A26981 fit on the A9S66163?

              Yes, that is designed to fit on the Acti9 shaped devices including the iSW switches.

              What items come with the KITWALLBOX7?

              A9Z51240 = Type B single phase RCCD
              A9F54240 = 2 pole, 40A, Curve MCB
              A9A26969 = Under voltage release

              What are the part numbers for Padlocking device which will go on LHS and RHS of Acti 9 iC60 and RCBO's?

              Part number A9A26380 is for mounting on the left side of Circuit Breaker.
              Part number A9A26381 is for mounting on the  Right side of Circuit breaker.
              For further details please follow the below link,
              https://www.tracepartsonline.net/(S(jj1xcpflpzf1tyxwjtna0vip))/partdetails.aspx?PartID=10-02112015-105620&class=SCHNEIDER_ELECTRIC_DISTRI&clsid=/SCHNEIDER_DISTRI/F_SCHNEIDER_DISTRI/SCHNEIDER_DISTRI.030/SCHNEIDER_DISTRI.030.010/
              Image result for A9A26380 schneider

              What is new code for Multi 9 26924 ?

              new code
              A9A26924
               

              What is the cheapest range of 24 pole MB distribution boards?

              The cheapest range of distribution boards available is the MB MSC standard range

              What RCCB is suitable for use in a VSD application?

              B type RCCB, 63 A 4 poles 30 mA sensitivity:  Part #16756

              If the customer wants to change the bridge with keeping its Remote, is it enough to switch it OFF and then to switch it ON in order to find the Base linked to the other bridge he wants to drive. Is it right ?

              If using a display remote device, a long reset (>5s) is enough.If using a LED remote device, the configuration SW is mandatory.

              What is the replacement for the NS250N series of CB?

              The replacement Series for the NS250N is the NSX250F.
              The NS250N was originally a 36 KA Fault level MCCB's which has now beeen replaced by NSX250F series.

              Please see below for a list of part numbers.

              For further information please visit Trade - Clipsal by Schneider Electric



               

              Why does ATV18 drive say ready but does not run?

              Issue: Why does ATV18 drive say ready but does not run?
               
              Product Line: ATV18
               
              Environment: All
               
              Cause: Not running
               
              Resolution: Jumper +24 to LI1 so will have a direction signal and with a speed reference present or LSP higher than 0hz the unit will run.


               

              Can the Full PME Hierarchy Configuration be Exported/Imported

              Issue
              Often times after creating a hierarchy within PME, it would be desirable to export and save the configuration outside of PME for backup purposes
              or for analysis in order to make further enhancements to the hierarchy.

              Product
              Power Monitoring Expert

              Environment
              Power Monitoring Expert 7.x, 8.x

              Cause
              The Hierarchy Configuration Utility does have the capability to export a partial or skeleton hierarchy configuration to Microsoft Excel. 
              The intent of this was to aid and expedite the creation of a hierarchy by extracting and associating devices to nodes within this skeleton
              configuration CSV file and importing the entries back into the Hierarchy Manager using the modified CSV file. This partial or skeleton hierarchy
              CSV file does not contain the full hierarchy configuration.

              Resolution
              A new feature added in PME 8, allows the export of the full hierarchy configuration to an XML file.  This can be done with the Hierarchy Configuration Utility.  The
              XML file can be viewed with an XML editor or a text editor such as Notepad++.  It is also possible to restore a entire hierarchy from a previously exported XML file.
              Instructions for both exporting and importing to the XML are found in the section "Saving and Restoring a Hierarchy Configuration" beginning on page 22 of the
              "Hierarchy Configuration Guide" (attached). 

              NOTE: Restoring a configuration XML file deletes the current hierarchy configuration and replaces it with the one represented in the file.

              For PME 7.2.2 and older, the Hierarchy Configuration Utility does not support Hierarchy configuration export in XML format