Quantcast

Clipsal - Powerguard Series, Twin Switch Socket Outlet, 250V 10A, 2 Gang, Safety Shut

White | Clipsal - Powerguard Series, Twin Switch Socket Outlet, 250V 10A, 2 Gang, Safety Shut

Clipsal - Powerguard Series, Twin Switch Socket Outlet, 250V 10A, 2 Gang, Safety Shut

Item Number: 951-WH

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

  • PDL
  • Powerguard

Product brand

Clipsal

Colour

body: white

Sustainable offer status

Green Premium product

Physical

Number of poles

1

[In] rated current

10 A

[Ue] rated operational voltage

230 V 50/60 Hz conforming to EN 60309-2

Connections - terminals

screw terminal

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

RoHS exemption information

Yes

Environmental Disclosure

ENVPEP060307EN

Material

Material

plastic

Others

Package 1 Bare Product Quantity

1

Voltage colour

blue

Duration

6 h

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

7.5 cm

Package 1 Width

16.0 cm

Package 1 Length

23.5 cm

Package 1 Weight

183.0 g
Show all specifications

Frequently Asked Questions

hide show

How to change the order of the Schedule in PICED so it sits in the correct order that you want on the wiser2 apps

Wiser2 apps Widget/Schedule not in order.

To change the order of the widget display in wiser2 apps.

PICED> In widget manager

  1. Aligning them from low to high by clicking the number column
  2. Highlight the widget  then drag and drop the widget in the order that you please

collum

 

The order can also be change for scheduler

  1.  Aligning the Schedules from low to high by clicking the number column
  2. Highlight the schedule widget  then drag and drop the widget in the order that you please

collums


 

Touch Panel 5000ETP10W how to Restoring factory defaults

Power cycle wait for 6 sec then hit and held down the On button until the screen display Erasing Content

fatory reset


 

Static IP Address fail to update when editing the 5000ETP10W Touch Panel

5000ETP10W Touch Panel IP Address fail to updating when entering a static IP address

When entering a fixed IP for the touch panel it is necessary to enter values into ALL fields, including DNS primary & secondary addresses, even if they are not going to be used.


static IP

 

DNS 1 and DNS2 need to be fill in overriding the default one i.e

0 0 0 0

0 0 0 0

 
 

In Aveva Plant SCADA why do the processes in Runtime Manager do not start randomly or Computer Role cannot be set to Server and Client (Multi-Process) in Setup Wizard

SUMMARY
In AVEVA Plant SCADA / Citect SCADA the processes in Runtime Manager do not start randomly and / or in the Setup Wizard on Computer Role page the Server and Client (Multi-Process) option is disabled or grayed out.

SITUATION
AVEVA PlantSCADA 2020R2 / Citect 2018R2 (and older versions)
OS – Windows Server 2019/2016, Windows 10/ 8/ 7

SYMPTOMS
Few of the Processes in the Runtime Manager don’t start randomly and every time the "Restart All" button is pressed only few of the Processes will run, as shown in Figure 1..
Runtime Manager
                                                 Figure - 1 (Runtime Manager)

And / Or the Server and Control Client (Multi-Process) option will get disabled in Setup Wizard (As shown in Figure 2) even though the machine has full Citect (server) installation / configuration on it.
Setup Wizard                                                                                                 
                                                    Figure -2 (Setup Wizard)

Root Cause
The name of the Computer is more than 15 characters and more than 1 Network Interface cards are used or configured on the computer. When the Computer name is more than 15 characters, the NetBIOS name of that computer gets limited to first 15 characters which may cause conflicts under NetBIOS name resolution.
Having Computer name as more than 15 characters with more than one Network Interface Cards will result in Runtime Manager’s Processes to behave abnormally. Also, if one of the two Network Interface Cards are used for Wifi, it may result in disabling the Server and Control Client (Multi-Process) option in the Setup Wizard.

ACTION
Limit the Computer name to 15 characters only.
 

Is there a Saturn series intermediate mech with LED ?

No, Saturn Intermediate Mechanism is 60PBI and is with no LED indication.
60PBI - 250V 10AX - Intermediate Push-button.

60PBI.png60PBI...png
 

Where to download the firmware (V 1.13.0) for SpaceLogic C-Bus Controllers NAC and AC?

The new firmware (version 1.13.0) for SpaceLogic C-Bus Controllers NAC and AC is available for download on se.com. and in Exchange Platforms

The new firmware version V1.13.0 is available for 5500NAC2, 5500AC2, 5500NAC, 5500SHAC, LSS5500NAC, LSS5500SHAC.

The main features of this new firmware release  (V1.13.0) are:
 

  • Scheduler Enhancement
  • Error reporting application improvements
  • Bug fixes

Related documents can be downloaded along with the firmware file:
  • Release Notes for V1.13.0
  • User Manual update for firmware V1.13.0
Links for www.se.com page and Exchange to download the firmware and the related documents:
 
 
5500NAC2
SpaceLogic C-Bus Network Automation Controller
Commercialized
 
 
Se.com: Link   
 
Exchange:
Firmware download page link
 
Direct link to the firmware file
 
5500AC2
SpaceLogic C-Bus Application Controller
Commercialized
 
 
Se.com: Link 
 
Exchange:
Firmware download page link
 
Direct link to the firmware file
 
5500NAC
C-Bus Network Automation Controller
End of Commercial
 
 
Se.com:  Link   
 
Exchange:
Firmware download page link
 
Direct link to the firmware file
 
5500SHAC
Wiser for C-Bus Automation Controller
End of Commercial
 
 
Se.com: Link
 
 
Exchange:
Firmware download page link
 
Direct link to the firmware file



 
Show More