905R

Plug, Round Earth, 10A, Heavy Duty

Catalogue Number: 905R
905R
Retail
$19.74
RRP (Inc. GST)
Colour White (WH)
  • White 1 PCE
  • Black 1 PCE

Specifications

hide show
Range of product
  • PDL
  • Series 900
    • Product brand
      Clipsal
      [In] rated current
      10 A
      Colour
      white
      Plug, socket, control station shape
      straight
      Package 1 Weight
      0.041 kg

      Frequently Asked Questions

      hide show

      What is the cord connector to suit the PDL 905R ?

      The cord connector to suit is Clipsal 438L

      What is the alternate for a Clipsal 439/15HD (PVC 15A Plug top)

      The 439/15HD is obsolete the alternate is 905

      I need a PDL 925R with a round earth pin (cord connector 10amp) rewirable

      PDL does not have a round earth cord connector 
      Clipsal range offer a 438L-we it has a round earth pin only availble in White in NZ

      How does 9050 JCK off-delay timer operate?

      Issue:
      Operation of the time function

      Product Line:
      Class 9050 Type JCK

      Environment:
      Timers

      Cause:
      n/a                   

      Resolution:                                                                 
      Control power is applied continuously. When the initiating contact is closed, the output contacts change state. Opening the initiating contact begins the time delay. At the end of the time delay, the output contacts go back to original state. Reclosing the initiating contact during the timing will cause the timing to start over when initiating contact is reopened.
       

      Is the 9050CO2DV66 timing relay still available?

      Issue:
      Availability of the 9050CO2D timing relay.

      Product Line: 
      Class 9050 Type C Relays and Timers

      Environment:
      North American Products

      Resolution:
      Obsolete with NO replacement.

      What is the repeat accuracy for the 9050 JCK general purpose timers?

      Issue:
      9050JCK accuracy

      Product Line:
      Class 9050 Type JCK Timers

      Environment:
      All type JCK

      Resolution:
      The 9050 JCK11 through JCK59 and the JCK1F through JCK5F have a repeat accuracy of + / - (plus or minus) 1%.  

      The 9050JCK60 and 9050JCK70 devices have a + / - (plus or minus) 0.1% repeat accuracy.

      How do you install the 8501NH7 strap?

      Issue:
      Adding the retaining strap onto the 9050JCK timer on the base.

      Product line:
      9050 JCK timer

      Environment:
      all

      Cause:
      Installation

      Resolution:
      The spring clip secures onto the side of the timer base.  See attached.

      What is the timing range for a 9050JCK70?

      Issue:
      Time Ranges available on the 9050JCK70

      Product Line:
      Class 9050 Type JCK Timers

      Enviroment:
      North American Products

      Resolution:
      The 9050JCK70 has 5 selectable timing ranges:
      0.5 to 9.99 seconds
      0.1 to 99.99 seconds
      1 to 999 secconds
      0.1 to 99.9 minutes
      1 to 999 minutes.

      How does the 9050JCK16 On Delay timer work?

      Issue:
      Installation and wiring for the 9050JCK1* On Delay timers.

      Product line:
      9050 Type JCK timer

      Environment:
      Adjustable On Delay timers

      Cause:
      No trigger contact for the timer function

      Resolution: 
      There is no trigger contact with the 9050JCK1* On Delay timers.  The timing function for on delay begins with the coil voltage being applied.  When the coil voltage is applied the timing period begins.  At the end of the timing period, the contacts will change state.

      To reset the timer, remove the coil voltage. 
       

      Where are Single-phase Symmetra frame serial numbers located?

      Issue:
      Where can the frame serial numbers of a single-phase Symmetra UPS be found?

      Product Line:
      Symmetra Power Array
      Symmetra RM
      Symmetra LX

      Environment:
      All serial ranges

      Cause:
      The frame model and serial number is used for logging and tracking single phase Symmetra technical support calls.  This information will be required when calling in for support.

      Resolution:

      The Symmetra Power Array, Symmetra RM, and Symmetra LX chassis/frame serial number is not obtainable through any UPS accessory, such as the PowerView or Network Management Card. The only way a customer can collect this information is to look on the UPS for the white sticker with the model and serial number information.

      The location of these stickers varies per Symmetra model:

      Symmetra Power Array: bottom, front of UPS. SYMSTRF, SYMINIF, etc.

      Symmetra RM 6kVA: front above System Enable switch behind display bezel, or rear bottom-left corner. SYHF6KT 

      Symmetra RM 12kVA: rear, bottom-right corner. SYPF12KT

      Symmetra LX: rear, upper center on UL/Certification Sticker. SYAFxxxx. For 2018 models and above there is also a sticker located on the front in bay R1 for easier access. 

      For Symmetra LX, the model number of the chassis will always begin with "SYAF". It is possible to find a second "configuration" sticker with part # such as SYA12K16RMP located under the System Enable/EPO panel.

      Please Note: The Serial Number provided via the PowerView is that of the PowerView display itself. The serial number and manufacturing date provided via the Network Management Card refers to Symmetra Main Intelligence Module that is in control of the UPS.