900 Series Plug Rear Entry, Heavy Duty, 10A, Locking Ring, Insulated Pins

Catalogue Number: 905LR
905LR
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
  • Series 900
  • PDL
    • Product brand
      Clipsal
      [In] rated current
      10 A
      Colour
      body: white
      Plug, socket, control station shape
      straight

      Frequently Asked Questions

      hide show

      What is the cord connector to suit the PDL 905R ?

      The cord connector to suit is Clipsal 438L

      Do we offer a 9001 KM LED light module at 480 volts AC?

      Issue:
      Do we offer a 9001 KM LED light module at 480 volts AC?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      Use the 480 volt transformer light module and a 6 volt LED. Example: 9001 KM5LR will be a 480 volt AC transformer light module and a red LED. All the transformer light modules with LED`s are set up on the system, but they are not listed in the literature.


      CTA-ID : 13535

      What is the difference between the 9065SR*** and 9065SS*** solid state overload relays?

      Issue:
      Difference between 9065SR*** and 9065SS***

      Product Line:
      Class 9065 NEMA Solid State Overload Relays
       
      Environment:
      North America Product

      Resolution:
      The 9065SS are separate mount units.  The 9065SR units are for retrofit only, into existing 8536 Type S starters.

      What is the warranty period for the ACES48 ceiling fans?

      The warranty period for the ACES48 ceiling fans is 3 years.
      The original purchaser of this Airflow Ceiling Sweep Fan is provided with the following warranty, subject to the following conditions:

      Schneider (Australia) Pty Ltd warrant this product for a period of three years from the date of purchase for all parts defective in workmanship or materials. All products used in commercial applications are limited to a 90
      day warranty. All defective parts will be replaced free of charge. The following exclusions do not preclude the purchaser from those statutory rights consumers have under the Trade Practices Act or similar:
      • SYMMETRA (M SERIES)
      • THIRD PARTY PROCUREMENT
      • COOLING EQUIPMENT SYS

      How to properly set FM condenser set points

      Issue: FM Condenser Set Points A350 Controller
       
      Product line: FM
       
      Environment: Data Center Cooling
       
      Cause:
       
      Resolution:
      The OHEs use A350A/B and S350A/B temperature controllers to regulate fan operation. These controllers operate on 24 VAC, and each provides an SPDT relay output. Each controller has a front panel LED that indicates when the relay is energized.
       
      Model LNH 1140 rpm Larkin
      Condensers
      Fan Config.
      1×N or 2×N

       
      A350 Set
      Point
      S1 ºC (°F)
      S350**
      OFFSET S2
      (°F)
      S350**
      OFFSET S3
      (°F)
      FM35 LNH-S01-A007
      LNH-S01-A011
      LNH-S02-A017
      1 x 1
      1 x 2
      1 x 2
      x
      90
      100
      x
      x
      x
      x
      x
      x
      FM40 LNH-S02-A011
      LNH-S02-A017
      LNH-S02-A026
      1 x 2
      1 x 2
      1 x 3
      87
      95
      110
      x
      x
      12
      x
      x
      x
      FM50 LNH-S02-A011
      LNH-S02-A017
      LNH-S02-A026
      1 x 2
      1 x 2
      1 x 3
      77
      90
      100
      x
      x
      10
      x
      x
      x

      Note:** Larkin wires A350A/B and S350A/B as NC, jumper positions in A350A/B and S350A/B as
      heating.