901

Standard Plug, Side Entry, 3 Pin, 10A

Catalogue Number: 901
901
Colour: White
Colour: Per UOM Std.
  • Black 1 PCE
  • Clear 1 PCE
  • White 1 PCE

Specifications

hide show
Range of product
  • Series 900
  • PDL
    • Product brand
      Clipsal
      [In] rated current
      10 A
      [Ue] rated operational voltage
      230 V 50/60 Hz conforming to EN 60309-2
      Voltage colour
      blue
      Colour
      white
      Plug, socket, control station shape
      angled
      Duration
      6 h

      Frequently Asked Questions

      hide show

      Can the 901 plug be used with 1.5mm cable?

      Yes, the 901 plug can be wired with 1.5mm ordinary duty flex.

      Some of the key features are:
      • Terminals accommodate conductors from 0.75 sq mm to 1.5 sq mm
      • Recommended for use with PVC insulated ordinary duty Three core circular flexible cords
      • AS/NZS3112, AS/NZS3100 standard
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=901

      What are the stand alone short circuit current ratings on the LC1D** contactors?

      Issue:
      Tesys D SCCR

      Product Line:
      Contactors and Overload Relays

      Environment:
      TeSys™ D Contactors and Overload Relays
       
      Resolution:
      The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

      They are as follows:
      Horsepower SCCR (A)

      0 thru 1 1,000
      1 thru 50 5,000
      51 thru 200 10,000
      201 thru 400 18,000
      401 thru 600 30,000
      601 thru 900 42,000
      901 thru 1600 85,000
      1601+ 100,000

      What is the R01 colour options

      R01 is an equipotential earth stud and it comes in green only

      What is the protective available mech N01 in the ML series ?

      The power available mech on its own is part number 30NPA.

      What is the shaft size for R01

      The shaft size is 8mm

      What is the voltage rating for the PDL 501

       The PDL 501 has a voltage rating of 415V AC

      What colours is the Clipsal 501 Lampholder available in?

      The 501 Lampholder available in black (BK) and white (WE).

      Can I get the 90B in orange?

      No. Unfortunately, the 90B only comes in black only.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=90B
       

      What is the part code for a Medilec R01 with a plate

      The part code is ML2031VR01-WE

      What is the alternate for a Clipsal 439/15HD (PVC 15A Plug top)

      The 439/15HD is obsolete the alternate is 905

      Is there a latching version of the PDL 951

       No - all portable RCDs are non latching for safety reason

      What does the *01 or *10 indicate at the end of the part number on the K-Line contactors?

      Issue:
      What does the *01 or *10 indicate at the end of the part number on the K-Line contactors?

      Product Line:
      TeSys K-Line Contactors

      Environment:
      All Product Lines

      Cause:
      The Digest does not specify.

      Resolution:
      the *10 will indicate a normally open auxiliary contact

      the *01 will indicate a normally closed auxiliary contact

      (example: LC1K0910 has one normally open auxiliary contact)

      What are the screws that come with a PDL 89DP

      Part number 201 dimensions 16mm x 6-32UNC

      What are the repair parts for a J250R, Series A01 or B01 circuit breaker enclosure?

      Issue:
      Repair parts

      Product Line:
      Circuit Breaker Enclosure

      Environment:
      Repair parts

      Cause:
      Maintenance

      Resolution:
      Only the parts listed below are considered field replaceable.
      Cover - At this point in time, the replacement cover for the J250R is not available. If a replacement cover is needed, order a new device. 
      Cover Mounting Screws - 4020513002K
      Circuit Breaker Cover - BCV (This is the smaller plastic cover that is attached to the larger metal cover)
      Top Endwall Closing Cap - ACPL



       

      What is the torque requirement on the 9013 type G?

      Issue:     
      What is the torque requirement on the 9013 type G?

      Product Line:
      Pressure Switches

      Environment:
      Class 9013 type G pressure switches

      Cause:
      What is the torque requirement on the 9013 type G?
       
      Resolution:
      The torque on the 9013 type G pressure switch, as well as the 9016GVG, is 17 to 21 pounds.

      Is there a specific shroud like the 90B to suit Slimline SC series or Saturn

      The 90BI-BK standard size intermediate type shroud will suit both the Slimline and Saturn series.
      For more information please visit the Clipsal web site on the link provided.
      https://www.clipsal.com/Trade/search-results?q=90BI
      User-added image

      Does the CPLEM422EM-E-KBTS and CPLEM422EM-E-KMTS come with a CT - Sensor

       Yes they both come with a 90A CT-sensor

      Do you sell replacement GU10 lamps for the 981 and 982 series downlights?

      No, unfortunately the 981 and 982 series downlights have been discontinued and we no longer sell the GU10 lamps.

      Other manufacturers still produce GU10 lamps but we cannot recomend a particular manufacturer. It would be trial and error process to see what lamp is suitable for your dimmer.

      For further information please visit 
      https://www.clipsal.com/Trade.
       

      Support on Buildings Management Systems and Pelco Security Solutions

       For support on Buildings Management Systems and Pelco Security Solutions please visit:  https://buildingskb.schneider-electric.com/

      What are the switching angles of the 7 Series rotary cam switches?

      Cams can be made with 30*, 45*, 60* and 90* switching angles.

      What does a 991 error code on a Circuit Monitor 2000 (CM2000 / CM2) display mean?

      Issue
      CM2000 Series meter's front display shows an alarm code "991" and user may not know what that means and how to fix it.

      Product Line
      CM2000, CM2050, CM2150, CM2250, CM2350, CM2450

      Environment
      Alarm code, Error Message, Power meter retrofit and replacement
       
      Cause
      If the front display of a Circuit Monitor 2000 displays a 991 message, this indicates an internal memory failure.

      Resolution
      It is possible that re-loading the latest firmware for the meter could correct the issue. If a firmware refresh does not correct the error, the unit will need to be replaced.

      The latest firmware for a CM2000 Series meter can be found in FA221408.

      See FA237920 for information on how to upgrade the CM2000 firmware and for a link to the firmware download utility, DLF-3000. 

      What is part code CPLEM422EM-E-KBTS and what comes with it?

      This is a Clipsal Ecomind Electricity Monitor and comes with one 90A  CT-Sensor, transmitter, USB cable, and battery powered digital display.
      There is also a CPLEM422EM-E-KMTS which has a power pack included for the digital display.
      Extra 90A CT's can be supplied for 2 & 3 phase installations, part number CPLEM422S-12C90A.

      How do I order a 9013 type G pressure switch with contacts that open on falling pressure?

      Product Line:

      9013 pumptrol pressure switches 
       
      Resolution:
       
      Add Form R (reverse action) to the class and type.


       

      Video 9013 FSG - Tutorial to help to install your Pumptrol pressure switch FSG

      See You Tube video @ providing help to install your Pumptrol power pressure switch FSG in class 9013
      https://www.youtube.com/watch?v=7_HfvvOASnk&index=2&list=PLSHNBITyPfumUojjnUPoUb5O_6hXKDBlI

      What are the 9013FHG pressure switch contacts rated at?

      Issue:
      Contact Rating of 9013F Pressure Switches

      Product Line: 
      Pressure, vacuum and Float Switches 

      Environment:
      9013 Type F Pressure Switch 

      Resolution:
      Those contacts have a control circuit rating of A600.
      They are DC rated at 1/4 HP at 115V and 230V (Except form M4)
      They are Single Phase AC rated 1 1/2 HP at 115V, 2 HP at 230V
      They are Polyphase rated 2 HP at 115V, 3 HP at 230V, and 1 HP at 460/575V.

      This also applies to the 9013 FHG2, 9, 12, 13, 44, 49 9013 FSG, and FSW.

      My XW+ is showing F01 instead of RPO with RPO switch closed.

      Issue
      The unit is displaying RPO behavior despite not showing "RPO" on the inverter display.

      Product Line
      Conext XW+

      Environment
      This is a system that intends to use the Remote Power Off (RPO) feature that is built-in to the Conext XW+

      Cause
      If the RPO setting is enabled AND the RPO switch is CLOSED before power-on, the XW will sometimes issue an F01 instead of an RPO message on startup. This is a rare condition between the RPO and fault detection signals.  The same situation can also prevent the inverter from charging.

      Resolution
      To reset condition, open RPO switch (if safe to do so). De-energize. Wait 1 minute. Re-energize. To prevent re-occurrence, make sure to reset RPO switch to OPEN before powering or re-powering inverter. 

      Severity Level is Incorrect in ISX Manager for High Temperature on External Sensor Violation Events

      "These alarms are incorrectly mapped in the ISX Manager. The ISX Manager defines these events as ""Critical"" while the Network Management Card defines them as ""Warning"" level events. There is no workaround for this issue at this time other than to make sure that the appropriate notifications are set up for Warning and Critical Level Events. "

      NSF Rating for 9013 pressure switches

      Issue:
      Are any of the 9013 pressure switches rated for food applications (NSF)

      Product Line:
      9013 Pressure Switches - GIC Product

      Environment:
      US Product

      Cause:
      Product Certifications

      Resolution:
      The 9013FR, 9013FS, 9013FT, 9013FY, 9013GM, 9013GS, and 9013GH pressure switches all carry the NSF marking.  Specific details reagrding compliance can be found on the attached document.

      Is there a lampholder BC, 3 piece cord grip, 501 with a short skirt avaliable?

      Yes, the part number for the  lampholder BC, 3 piece cord grip, 501 with a short skirt is 501S.
      Some of the key features are:
      • 3 piece cord grip
      • Voltage rating: 250 V
      • 3A
      • With Short Skirt
      For further details please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=501S
       


       

      Why is my Conext CL showing an alarm code: 701 & 706 (DC Injection Err & DC Injection Inst Service Alarm)

      Issue: 
      Customer is calling in requesting support for an alarm code: 701 & 706 (DC Injection Err & DC Injection Inst Service Alarm Code)

      Product Line: 
      Conext CL 18000NA Conext CL 25000NA Conext CL 20000E Conext CL 25000E

      Environment:  
      On site troubleshooting

      Resolution: 
      Turn off and on the AC breaker
      If problem persists, replace the inverter

      Cause:
      External transformer saturation, impedance change, resonance
      Internal: component failure due to degradation
      The DC average content (or instantaneous) of AC output current is above setting value 

      What are the part number needed for 3 pole, 20A load break switch, din rail mounted?

      The part number needed for 3 pole, 20A load break switch, din rail mounted is V01 + VZ17 + KZ32 + KCF1PZ

      For more information see :https://www.schneider-electric.com.au/documents/catalogue/2013-2014-schneider-electric-australian-catalogue/index.htm
      PAGE 3.1.59

      IN THE ECOMIND, CAN THE TRANSMITTER AND THE SENSOR BE PURCHASED SEPARATELY ?

      THE SENSOR LEADS CAN BE PURCHASED SEPARATELY BUT NOT THE TRANSMITTER.
      The Ecomind comes complete with the Display screen and transmitter which also  comes standard with one 90a lead for single phase monitoring , but extra 90a or 120a leads can be purchased for Larger current ratings or if extra leads are required for 3 phase monitoring
      Complete unit is EM422EM-E-KMTS ( mains powered transmitter option)
                                     EM422EM-E-KBTS ( Battery powered transmitter option )
                                     EM422S-12C90A ( 90a leads )
                                     EM422S-16C120A ( 120a lead )

      For more information on this product range please visit the Clipsal web site on the link provided https://www.clipsal.com/Trade/search-results?q=EM422

      Is the pressure relief valve, Form X, of a 9013GHG2X field replaceable ?

      Product Line:
      9013 pressure switches

      Resolution:
      Yes, the valve can be replaced, 9049A12, on 9013G switches that were delivered with Form X. However, this is not a field retrofit for products that were not delivered with the Form X.


      CTA-ID : 850

      What is the VA rating of a 9001KM transformer light module?

      Issue:
      What is the VA rating of a 9001KM transformer light module?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      9001 KM2 110-120 volt 25-30 hertz      2.2 VA
      9001 KM1 110-120 volt 50-60 hertz      2.4 VA
      9001 KM3 208-220 volt 50-60 hertz      2.5 VA
      9001 KM4 220-240 volt 25-30 hertz      2.2 VA
      9001 KM7 220-240 volt 50-60 hertz      2.0 VA
      9001 KM8 277 volt 50-60 hertz             2.4 VA
      9001 KM5 380-480 volt 50-60 hertz      2.8 VA
      9001 KM6 550-600 volt 50-60 hertz      2.5 VA

      Can we change a 9001 KS43B to a 9001 KS63B?

      Issue:
      Can a 9001 KS43B convert to a 9001 KS63B?

      Product Line:
      Push Button and Operator Interface 

      Environment:
      9001K 3-Position Selector Switches

      Resolution:
      Cannot change from maintained to spring return. Must replace the operator. Basic operator is 9001 KS6. 
       

      Does the alarm log in Vijeo Designer V4.5 overwrite once I reach the memory limit?


      The alarm log is a circular buffer. It means that, once it filled up, new alarm events will overwrite the oldest alarm events. For example, if your alarm log size is set to 100 records, it will work like this:
      - events 1 to 100 will fill up the alarm log.
      - event 101 will overwrite event 1.
      - event 102 will overwrite event 2.
      ....................
      - event 199 will overwrite event 99.
      - event 200 will overwrite event 100.
      - event 201 will overwrite event 101.
      etc...


      Legacy KB System (APS) Data: RESL183431 V1.0, Originally authored by MiMe on 04/10/2007, Last Edited by MiMe on 04/10/2007
      Related ranges: Vijeo Designer

      What does Error 801 mean in Concept?


      This error occurs when Concept cannot find a loadable on the disk when doing a compare or a download.
      Make sure that all your user loadables are in the Concept\Dat directory.


      Legacy KB System (APS) Data: RESL163984 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Concept

      What is the voltage for part no 6508805212??

      Super bright LED bulbs
      24 V / 9001 ppp35L---6508805210
      or 48 V / 9001 ppp36L--- 6508805212
      or 120 V / 9001 ppp38L---6508805211
       

      What is the ATS48 soft starters dissipated watts loss for calculating heat loss for enclosure sizing?

      Issue:
      What is the ATS48 soft starters watts loss for calculating heat loss for enclosure sizing?

      Product Line:
      Altistart ATS48 soft starters

      Environment:
      All

      Cause:
      Needs to know the dissipated heat loss in watts the ATS48 soft starter will produce when running at full load.

      Resolution:
      See the table below and choose the ATS48's watt loss based on if a shorting contactor is being used or not.




      TAI : 2021691
       

      Can C-Bus Ripple software run on Mac ?

      No, C-Bus software can only be run in Windows

      The C-Bus Ripple software is an application you run on your personal computer to stream music to an MRA Matrix Switcher. The software will catalogue your music collection and allow you to sort it in many ways including album art. This also allows advanced control of music selection via C-Bus.

      https://www2.clipsal.com/cis/technical/downloads/general_utilities#CBusRipple

      Who can I contact for PowerLogic Support?

      Issue:
      How to do I get support on the powerlogic products

      Product Line:
      1. Power-Power Monitoring products

      Resolution:
      The Schneider Electric Industry support group provides support on the PLC and HMI.  But for powerlogic equipment and system application you can contact 888-797-6468 Option 5.


       

      Can a 9012GAR5 be used on water systems?

      Issue:     
      Can a 9012GAR5  be used on water systems?

      Product Line:
      Pressure Switches

      Environment:
      9012 Pressure Switches

      Resolution:
      Yes, all components are compatible with water systems. However, salt water may attack standard flange material and may work best with 9013F Form Q. It is important to note that these switches are control rated devices. An interposing starter, or contactor must be used for switching a pump motor . Low level signals to PLCs or computers requires the use of an interposing low level switching relay.


       

      How can EM422EM-E-KBTS and EM422EM-E-KMTS be used for three phase monitoring?

      For three-phase installations, two additional sensors are required.
      EM422S-12C190A: Clamp-type sensor, suitable for 90A cables up to 12mm diameter.
      EM422S-16C120A: Clamp-type sensor, suitable for 120A cables up to 16mm diameter.

      Can EM422EM-E-KMTS or EM422EM-E-KBTS measure three phase ?

      In three-phase installations, two additional sensors may be required.

      Ecomind Sensors that can be purchased separately:
      EM422S-12C90A: Clamp-type sensor, suitable for 90A cables up to 12mm diameter.
      EM422S-16C120A: Clamp-type sensor, suitable for 120A cables up to 16mm diameter.
       

      What is a 9001 AS2?

      Issue:
      What is a 9001 AS2?

      Product Line:
      Harmony Push  Buttons

      Environment:
      All 30mm Push Buttons

      Cause:
      Kit compnents

      Resolution:
      This is a member of the Point of Purchase, or POP, system. These are devices packaged in plastic clam shells to display on a peg board at a distributor. The 9001 AS2 consists of a 9001 KS43BH13 and a 9001 KN260.


      CTA-ID : 2022285

      What is the heat dissipation and minimum required air flow rate for each of the Altivar 900 Process Drives?

      Issue:
      What is the heat dissipation and minimum required air flow rate for each of the Altivar 900 Process Drives?

      Product Line:
      Altivar 900 Process Drives

      Environment:
      All serial numbers for Altivar 900 Process Drives

      Cause:
      N/A

      Resolution:


               
                              
       

      What is the seal kit for the 9012GAW5?

      Issue:
      What is the seal kit for the 9012GAW5?

      Product Line:
      Float, Pressure and Vacuum Switches

      Environment:
      All Products

      Cause:
      Product selection

      Resolution:
      9998PC184 gasket kit.


      CTA-ID : 2028834

      what is longest trunking?

      Clipsal 900 series Maxi Duct trunking comes in lengths of 4 metres.

      Where can I get the Modbus Registers for the Altivar 900 Process Drives?

      Issue:
      Modbus Registers for the Altivar 900 Process Drives?

      Product Line:
      Altivar Process Drives

      Environment:
      All serial numbers for Altivar Process Drives

      Cause:
      N/A

      Resolution:
      Attachment - Document Reference: NHA80944

      What are the part numbers needed for 3 pole, 20A lad break switch, din mounted?

      The part numbers needed for 3 pole, 20A lad break switch, din mounted is V01 + VZ17 + KZ32 + KCF1PZ
      Image result for vz17 schneider