Block MTG Trunking Surf STD

Block MTG Trunking Surf STD

Block MTG Trunking Surf STD

Item Number: 900SPMB-WE

Retail
$40.19
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE
  • Brown 1 PCE
  • Grey 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

97.5 g

Package 1 Height

3.8 cm

Package 1 width

7.3 cm

Package 1 Length

11.5 cm
Show all specifications

Frequently Asked Questions

hide show

What size entry(s) does the 900SPMB have?

The 900SPMB has four 25 mm x 16 mm trunking entries, one at each side and end.

Does the 900spmb come in black?

No, the 900SPMB comes in White Electric, Grey and Brown.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=900SPMB

What size Duct Entry does the 900RMB have?

It has 2x 25x16mm entries (one at each end).

Why are 9001KM38 listed twice, as resistor and full voltage light modules?

Issue:
Is the 9001KM38 a resistor type or full voltage type of light module?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Cause:
Product Features

Resolution:
Both descriptions are accurate. They are both the same device but can be selected by either description depending on the application/preference.

Does the Clipsal 900 RMB have a lid?

The 900RMB is a mounting block for round surface sockets. It does not have a lid as it is not designed as a junction box.

What is the difference between a 9001K7 and 9001K7B?

Issue:
What is the difference between a 9001K7 and 9001K7B?

Product Line:
Pushbuttons and Operator Interface

Environment:
9001K, SK Operators

Resolution:
9001K7 the cover can be be locked with the knob in any position. 9001K7B the knob must be straight up and down to lock the cover.

What is the parts breakdown of a 9001KP1R31?

Issue:
9001KP1R31 components

Product Line:
Harmony Pushbuttons

Environment:
All Products

Resolution:
It consists of a 9001KM1 light module, 9001KP operator and a 9001R31 lens.

How can the 9001KM5 use a 6V lamp?

Issue:
9001KM light module

Product Line:
30 mm Push Buttons

Environment:
Type K, SK and KX Electrical Components

Resolution:
This light module uses a transformer that drops voltage to the lamp to 6 volts.

What kind of application is this relay RM35S0MW built for? How to use it ? Is there some limitation?

Goals and Symptoms

What kind of application is this relay RM35S0MW built for?
How to use it ?
Is there some limitation?

Facts and Changes

RM35S0MW

Causes and Fixes

Speed Measurement and Control Relay

The relay counts the time between each pulse and evaluates the speed.
This value is compared with the preset value to determine whether if the system is under or over speed. The pulse interval can vary from 0.05 seconds to 10 minutes

The main application are escalators, monitoring of rotation speed, transporter or conveyor belt speed, pump rotation, industry process systems..

Interval between pulses (measurement range) corresponds to frequency (Hz) and speed (rpm):
Time Frequency (Hz) Frequency (rpm)
0.05 to 0.5s 2 to 20 120 to 1200
0.1 to 1s 1 to 10 60 to 600
0.5 to 5s 0.2 to 2 12 to 120
1 to 10s 0.1 to 1 60 to 6
0.1 to 1 mn 0.017 to 0.178 1 to 6
0.5 to 5 mn 0.033 to 0.33 0.2 to 2
1 to 10 mn 0.0017 to 0.017 0.1 to 1
A relay can only control one characteristic: Undervoltage or Overvoltage.
You cannot do both. On the other hand, you must use 2 relays and select it with the knob N°1. Then you select the range (Knob N°3) and adjust % (Knob N°2) according to the speed to control.

Example :
A speed 900rpm corresponds to 15Hz(900/60) and then to a time of 0.067s. You select with the knob N°3 the time range 0.05 to 0.5s and the select 13.33% with knob N°2

Currently, we do not have another relay that control a speed higher than 1200rpm.
If you have a speed higher, you can use a reduction gear


Legacy KB System (APS) Data: RESL197713 V1.0, Originally authored by BrCa on 09/02/2009, Last Edited by BrCa on 09/02/2009
Related ranges: Zelio Control

What is the VA rating of a 9001KM 120V LED light module?

Issue:
What is the VA rating of a 9001KM 120V LED light module?

Product Line:
Push Buttons and Operator Interface

Environment:
30mm, 9001KM, 9001K, 9001SK

Resolution:
All 9001KM 120V LED:  9001KM38LR, 9001KM38LG, 9001KM38LY, 9001KM38LW, 9001KM38LL have a  1.4VA rating.

What is the difference between transformer and full voltage in the 9001KM light modules?

Issue:
Difference between transformer type and full voltage type light modules.

Product Line:
Harmony Push Buttons

Environment:
Harmony 30mm

Resolution:
All transformer light modules have a secondary of 6 volts, so they all use 6 volt lamps, no matter what the primary. With full voltage you must use a bulb of the same voltage as the input voltage.


 

What is the VA rating of a 9001KM transformer light module?

Issue:
What is the VA rating of a 9001KM transformer light module?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Cause:
Product Features

Resolution:
9001 KM2 110-120 volt 25-30 hertz      2.2 VA
9001 KM1 110-120 volt 50-60 hertz      2.4 VA
9001 KM3 208-220 volt 50-60 hertz      2.5 VA
9001 KM4 220-240 volt 25-30 hertz      2.2 VA
9001 KM7 220-240 volt 50-60 hertz      2.0 VA
9001 KM8 277 volt 50-60 hertz             2.4 VA
9001 KM5 380-480 volt 50-60 hertz      2.8 VA
9001 KM6 550-600 volt 50-60 hertz      2.5 VA
Show More