Is the 900/75C sold individually or in pairs

 900/75C-WE sold individually

Are the 9001K51 and 9001K52 closing plate metal or plastic?

Issue:
Requested to clarify if the 9001K51 and 9001K52 is metal or plastic before purchase.
Product Line:
30mm Closing Plate
Environment:
30mm K and SK control stations, 9001K51 and 9001K52 30mm 30 mm 9001 9001k plug hole enclosure ky sky kyp skyp control station box accessories accessory   Push Buttons
Cause:
Request from vendor before purchase is placed
Resolution:
The closing plate both 9001K51 and 9001K52 is plastic with a metal ring nut that secures the plate to the enclosure.  Meets UL and Nema 1, 2, 3, 4, 4x, 6, 12, and 13.
 

Is the head of 9007C rotatable?

Issue:
9007C head orientation

Product Description:
9007C Limit Switches

Environment:
North American Products

Resolution:
Yes.  With the 4 screws removed off the headit can be rotated.

Is there any technical information available for the old range of XCKJ safety limit switches?

Yes, there is technical information in the attached file named “XCKJ59-79_1995 catalogue pages”.
 

 

 

How to join 900/75/50 trunking pieces together (not elbows)

 You need to use a 900CC-WE trunking connector

What is the clamping diameter for the 9007BA1 arm for some 9007C limit switches?

This relates to the 11 mm diameter of the shaft for the related 9007C rotary limit switches.

Refer to the attached pdf file named "dimensions in Square D limit switches 2004 9007CT0401".

What is the code for the divider / separator for 900/75/75 trunking?

900D75S-WE

What does form Y203 mean on the 9007C series limit switches?

Issue:
What does form Y203 mean on the 9007C series limit switches?

Product Line:
IDSEN - sensors

Environment:
9007C

Cause:
product feature

Resolution:
The Form Y203 or (Y20-3) is for the factory modification to rotate the Turret head 180 degrees from its standard position.
However, this form is no longer available but the modification can be done in the field. The head can actually be rotated
 360 degrees in 90 degree increments.

Can the head on 9007C limit switches be rotated?

ISSUE
 9007C limit switch head rotation

PRODUCT LINE
Limit switches

ENVIRONMENT
9007C

CAUSE
Adjustments or modifications 

RESOLUTION
Yes, the head can be rotated 360 degrees in 90 degree increments.

What is the part number for the current measurement board for the ATS46 softstarter?


Issue: Current measurement board part number
Environment: Replacement parts
Cause: current measurement board failure.
Resolution: See attached document for the current measurement board part numbers. Note: The current measurement boards for all ATS46 models are obsolete and no longer available. The ATS46 softstarter should be replaced with the current version of ATS48.

What is the replacement for the hooped delrin lever arm shown in the Digest as 9007FA9?

Issue:
What is the replacement for the hooped delrin lever arm shown in the Digest as 9007FA9?

Product Line:
Digest 177 Section 21 : Limit Switches

Environment:
North American Products

Cause:
Needs the replacement for the hooped delrin lever arm shown in the Digest as 9007FA9.

Resolution:
The Digest incorrectly shows this unit as 9007FA9.  The correct part number is 9007FA6.

Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

ISSUE
Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?
PRODUCT LINE
Auxiliary contacts for the Tesys D line
ENVIRONMENT
Tesys D-Line and Tesys F
CAUSE
Fit
RESOLUTION
These contacts will only fit on the following contactors:
Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
Left side mount only to LC1F contactors
CTA-ID : 2002751

What is the ``solid red`` only knob that can be used on the 9001KR9R or 9001SKR9R push-pull operator?

Issue:
Is there a part number for a solid red knob used on our push pull operators?

Product Line:
Harmony Push Button

Environment:
Harmony 30mm

Resolution:
The 9001R20 (1-3/8`` red mushroom) or the 9001R21 (2-1/4`` red mushroom) can be used for ``solid red`` buttons only.
When used on 9001KR9R or 9001SRK9R operators, 9001R20 and 9001R21 mushroom knobs must be used in conjunction with adapter ring 9001K54 which is available for the purpose at no charge.``)

What is the breakdown of components for 9001KYK117?

Issue:
What is the breakdown of components for 9001KYK117?  

Product Line:
Harmony Push Buttons

Environment:
Harmony Control Stations

Cause:
Product Features

Resolution:
9001KYK117 components are:
1-9001KY1S1 (red enclosure)
1-9001K15 (break glass operator)
1-9001KA1 (1 open and 1 closed contact)
1-9001KN799RP (legend plate)

Replacement glass discs are 9001K57 (package of five)