Quantcast

Maxi Duct Fittings, Couplings - Grey, 100mm

Grey | Maxi Duct Fittings, Couplings - Grey, 100mm

Maxi Duct Fittings, Couplings - Grey, 100mm

Item Number: 900/100C-GY

Retail
$86.35
RRP (Inc. GST)
Colour Grey (GY)
  • Grey 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

Length

100 mm

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Material

Material

PVC (polyvinyl chloride)

Others

Package 1 Weight

0.016 kg
Show all specifications

Frequently Asked Questions

hide show

Is the 900/75C sold individually or in pairs

 900/75C-WE sold individually

What is the code for a 2-gang conversion plate for PDL 500/600 series?

Part code is PDL 538

What is the replacement mechanism for the surge protection in a 2025SF?

The replacement for the surge protection in a 2025SF is the 30SFM.

Some of the key features are:
  • Peak current (8/20µs) 6.5 kA
  • Maximum clamping voltage (8/20 µs, 100 A) 710 V
  • Energy absorption (10/1000 µS) 3 x 140J
  • Impulse response time <50 ns

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30SFM



 

Reject obsolete Is S383 an option with the Altivar 71 drives rated for 500/600 Vac?

Issue:
Is S383 an alternative with the Altivar 71 drives rated for 500/600 Vac?

Product Line:
Altivar 71 drives

Environment:
ATV71 ....Y
 
Cause:
Product Selection

Resolution
No, the S383 is not an option with the ATV71 ....Y versions.

Com'X 500/200 - "Could not parse response code. Server Reply: SSH-2.0" when publishing data

Issue 
When connecting to SFTP server to publish data, gives an error: "Could not parse response code. Server Reply: SSH-2.0"

Product Line
Com'X 200/210 (EBX200/210)
Com'X 500/510 (EBX500/510)

Environment
Com'X 500/200 Publishing Data to the SFTP server

Cause 
In Com'X 500/200 series, SFTP is not supported for data publishing. Remote SFTP Server is expecting to use SFTP protocol and SSH connection not plain FTP.

Resolution 
Four(4) supported Transfer Protocols by COM'X 500/200 series are:
  1. HTTPS
  2. HTTP
  3. FTP 
  4. SMTP
For Publication, FTP is not recommended, instead either HTTPS with authentication, or SMTP with either SSL/TLS or SMART TLS configured for publication are recommended.

For any reason if FTP Transport is the only possible option, then port 21 on remote server needs to be open.
Connection on Port 21 is for FTP and Port 22 is for SFTP/SSH.

Here are the User guides for the Com'X 500/200 series:

200/210
https://www.schneider-electric.com/en/download/document/DOCA0036EN/
500/510
https://www.schneider-electric.com/en/download/document/DOCA0098EN/
 

Many customers use brake resister with ATV58. Can you tell me the DC voltage when the brake begin? And how large brake current(DC) can ATV58 sustain c...

Goals and Symptoms

Many customers use brake resister with ATV58. Can you tell me the DC voltage when the brake begin? And how large brake current(DC) can ATV58 sustain continuously?

Causes and Fixes

The braking transistor is started at:

800 V ( DC bus ) for 400/500V ATV58 range
395 V ( DC bus ) for 200/240V ATV58 range


Legacy KB System (APS) Data: RESL154896 V5.0, Originally authored by on , Last Edited by on
Related ranges: Altivar 58