Maxi Duct Fittings, Internal Elbows - Grey, 100 x 100mm

Maxi Duct Fittings, Internal Elbows - Grey, 100 x 100mm

Maxi Duct Fittings, Internal Elbows - Grey, 100 x 100mm

Item Number: 900/100100EI-GY

Retail
N/A
RRP (Inc. GST)
Colour Grey (GY)
  • Grey 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Series 900

Sustainable offer status

Green Premium product

Physical

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP100802EN

Material

Material

PVC (polyvinyl chloride)

Others

Package 1 Weight

0.44 kg
Show all specifications

Frequently Asked Questions

hide show

What is the part number for a coupling for the 900/100/100?

The part number for a coupling for the 900/100/100 is - 900/100C
For further information, visit the link below:-
https://www.clipsal.com/Trade/search-results?q=900/100C
User-added image

Is there an Internal Elbow for truning size 150 x 50mm Maxi Duct Drunking?



No, largest internal elbow available is 900/100/100EI

Does the trunk mate for a Clipsal 900/100/100GY come in different sizes

No

Does the 900/100/100-GY come with a removeable lid

Yes it does.

Does the 900/100/50-GY trunking come with a Separator

No the 900D50S needs to be bought seperately.

What is the part code for a trunking divider 100mm

The part code is 900D100S-WE

How do I change the Profibus address on the ATV61 or ATV71 with an optional Profibus card?

Issue:
How do I change the Profibus address on the ATV61 or ATV71 with an optional Profibus card?  

Product Line:
Altivar 61, Altivar 71

Environment:
Profibus network

Cause:
Configuration

Resolution:

Profibus card part numbers are VW3A3307 or VW3A3307S371.

The profibus address is set through a series of 8 dip switchs on the card beside the 9 pin profibus connector.  The address is set in binary form.  A switch in the up position indicates 0 and in the down position indicates 1.  The least significant bit is the far right switch. Example, to set the address to 36 (binary 00100100).  Place the switches in order from left to right: UP, UP, DOWN, UP, UP, DOWN, UP, UP.



Refer to page 11 in either of the attached Profibus manuals for switch configurations. You can also download the manuals using these links:

ATV61/71 Profibus DP manual - VW3A3307
https://www.schneider-electric.us/en/download/document/1755873/

ATV61/71 Profibus DPv1 manual - VW3A3307S371:
https://www.schneider-electric.com/en/download/document/AAV52935/

NetBotz 750 | Network Port Light Indicators

Issue:
   Description of the Network Port lights (Link/Status) on NetBotz version 5.

Product Line:
   NetBotz version 5
      - Rack Monitor 750

Environment:
   NetBotz v5.X

Resolution:

Link (10/100/1000) LED
The LED on the right of any network port indicates the network status.
 
Condition Description
Off One or more of the following situations exist:
  • The Appliance is not receiving input power.
  • The cable that connects the appliance to the network is disconnected or not functioning properly.
  • The appliance is turned off or not operating correctly. It may need to be repaired or replaced. Contact Customer Support at www.apc.com/support.
Solid Green The appliance is connected to a network operating at 100 Megabits (Mb) per second or 1000 Mb/1 Gigabit (Gb) per second.
Solid Orange The appliance is connected to a network operating at 10 Mb per second.
Flashing Green The appliance is receiving or transmitting data packets at 1 Gb per second.
Flashing Orange The appliance is receiving or transmitting data packets at 10 Mb or 100 Mb per second.

Status LED
The LED on the left side of any network port indicates the status of the appliance.
 
Condition Description
Off One of the following situations exists:
  • The appliance is not receiving input power.
  • The appliance is not operating properly. It may need to be repaired or replaced. Contact Customer Support at www.apc.com/support.
Alternately Flashing Green and Amber The appliance is waiting for a DHCP server to assign a valid IP address.
Solid green The appliance is on and has a valid IP address.

Where can we find information on Berger-Lahr products?

Berger Lahr Motion Technology is a division of Schneider Electric.

Berger Lahr offers a complete Motion Control product range for machine automation. In addition, Berger Lahr develops and manufactures customized products and solutions, based on its standard products. In 2008, Berger Lahr changed the company name to Schneider Electric Motion Deutschland, and integrated its products and services into the offering of Schneider Electric. The motion products are a part of Schneider Electric's Lexium range.

Learn more these products and technologies here:
https://www.schneider-electric.com/en/brands/berger-lahr/

What are the replacement interiors for the 9001BW Pendant control stations?

 Issue:
Needs the replacement contacts or interior for 9001BW pendant stations

Product line:
9001BW Pendant control

Environment:
North American Products

Resolution:
Note replace the * with the enclosure color Y = yellow, B = black R = red
9001BW92* - replacement interior is 9001BOC368
9001BW93* - replacement interior is 9001BOC368
9001BW94* - replacement interior is 9001BOC358
9001BW95* - replacement interior is 9001BOC359
9001BW96* - replacement interior is 9001BOC358
9001BW97* - replacement interior is 9001BOC359
9001BW98* - replacement interior is not available

9001BW90*U - replacement interior is 9001BOC366
9001BW91*U - replacement interior is 9001BOC359
9001BW94*U - replacement interior is 9001BOC358
9001BW100*U - replacement interior is 9001BOC367
9001BW102*U - replacement interior is 9001BOC367

Can the EGX400 or ECC21 fiber port connect directly to a gigabit (1000 Mb) network?

Issue:
User would like to communicate with an EGX400 or ECC21 using a gigabit (1000 Mb) fiber network
 
Product line:
ECC21, EGX400
 
Cause:
Customer wanted to know if they can directly connect 1000Mb a gigabit) fiber connection to EGX400 or ECC21 fiber port?
 
Resolution:
Customer cannot connect a 1000Mb fiber connection directly to the ECC21 or EGX400.
As per the ECC21 and EGX400 Installation Manuals, the fiber port is compatible with 100Mb networks only.
If gigabit fiber network connections are needed, a 100Mb multi-mode LC fiber converter will be required. 

Alternately, a gigabit fiber switch with 10/100/1000 copper ethernet connections could be used. In this instance, the fiber would be run to the switch and 10/100 ethernet to the EGX or ECC gateway.
 

NetBotz 750 | Physical Description

Issue:
   Physical Description of the NetBotz 750

Product Line:
   NetBotz version 5
      - Rack Monitor 750

Environment:
   NetBotz v5.X

Resolution:

Physical Description



 
Item Description
1 AC line inlet Input power connection.
2 Switched Outlet Provides power to a device at a maximum of 10 A. Activates a connected device when configured events occur. (For example, a fan may be connected to this outlet, and the outlet may be configured to turn on when certain alarms are generated.)
3 A-Link ports Provide communications and power to connected devices (sensor pods, rack access pods, and temperature/humidity sensors with digital displays) over standard CAT-5 cabling with straight-through wiring. For instructions to cascade devices, see the Installation and Quick Configuration Manual.
4 Leak Rope ports Used for connecting a NetBotz Leak Rope Sensor (NBES0308).
5 Rack Access Ports* Ports for the door switch sensors (NBES0302 or NBES0303) and handle sensors (NBHN125 or NBHN1356).
6 Universal Sensor ports Used to connect APC by Schneider Electric sensors, third-party dry-contact sensors, and standard, third-party 0-5 V sensors. Third-party, dry-contact state sensors require the NetBotz Dry Contact Cable (NBES0304), and third party, 0-5 V sensors require the NetBotz 0-5 V sensor cable (NBES0305).
7 Beacon Port Used for connecting an Alarm Beacon (AP9324).
8 10/100/1000 Network Port Provides a connection to the network. Status and link Light-emitting Diodes (LEDs) indicate network traffic. See Link LED and Status LED for additional information.
9 Private LAN Provides a 10/100/1000 connection to a private local area network and 48 VDC to an attached device.
10 Wireless Sensor Coordinator USB Port with Wireless NetBotz USB Coordinator (NBWC100U) installed. Used with wireless sensors.
11 USB Type A Ports Reserved for future use.
12 Modbus RS485 Port Reserved for future use.
13 Voltage Output Provides 12 VDC or 24 VDC (75 mA) to one connected device.
13 Relay Output Used for connecting relay-controlled external devices. Relay Outputs can only be connected to Class 2 circuits.
14 4-20 mA Inputs Inputs for industry standard 4-20 mA sensors.
15 Console Port Provides a serial connection to the appliance.
16 Power LED Illuminates when the unit is receiving power.
17 Reset Switch Reboots the appliance.
18 Exhaust fan Exhausts hot air from the appliance.
*Note supported on firmware version 5.0.1. Update the firmware to access these features.
Show More