elbow flat trunking 50x100

Maxi Duct Fittings, Flat Elbows - Grey, 100 x 50mm

Catalogue Number: 900/100/50E

Discontinued

elbow flat trunking 50x100
Colour: Grey
Colour: Per UOM Std.
  • Grey 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Series 900
Material
PVC (polyvinyl chloride)
Sustainable offer status
Green Premium product
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
ENVPEP100802EN

Frequently Asked Questions

hide show

What is the part number for a coupling for the 900/100/100?

The part number for a coupling for the 900/100/100 is - 900/100C
For further information, visit the link below:-
https://www.clipsal.com/Trade/search-results?q=900/100C
User-added image

Does the 900/100/50-GY trunking come with a Separator

No the 900D50S needs to be bought seperately.

Is there an Internal Elbow for truning size 150 x 50mm Maxi Duct Drunking?



No, largest internal elbow available is 900/100/100EI

Does the trunk mate for a Clipsal 900/100/100GY come in different sizes

No

Is 900/50/50 PVC Maxi duct UV resistant?

Unfortunately not, they are not UV resistant. 

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=900/50/50

What is the part code for a trunking divider 100mm

The part code is 900D100S-WE

What is the code for the end cap on 900/50/50 Trunking?

900/50/50P-GY

 

Does the 900/50/50 duct come in black?

No, unfortunately the PVC Maxi Duct only comes in grey.

Some of the key features are:
  • Rectangular
  • Screw or double sided tape fastening

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=900/50/50

Does Clipsal have duct, ie: 900/16/10, in the HFT series?

No, we don't have any 900 series duct in HFT.

 

What is the part number for the terminal sheilds for the NSX 100/160/250 C/B's?

The part numbers for the terminal shields for the NSX 100/160/250 C/B's are -  

SHORT SHEILDS,
3 pole - LV429515,
4 pole - LV429516. 

LONG SHEILDS,
3 pole - LV429517,
4 pole - LV429518


For further information, visit the links below:-
https://www.schneider-electric.com.au/en/search/LV429515
https://www.schneider-electric.com.au/en/search/LV429516
https://www.schneider-electric.com.au/en/search/LV429517
https://www.schneider-electric.com.au/en/search/LV429518
User-added image
User-added image

Are there End Plugs available for the 150 x 75mm (900/150/75) Maxi Duct Trunking?

We do not currenlty stock any fittings for the 150 x 75mm Maxi Duct - This includes End Plugs, Internal, External and Flat Elbows etc...

Do you do internal and external Elbows for the duct 900/60/40?

No, unfortunatley for this size duct we do not offer internal or external elbows.

For further information please visit
https://www.clipsal.com/Trade/search-results?q=mini%20duct
 

Is part number 900/40/25/2 available in Black?

Unfortunately, part number 900/40/25/2 is only available in White & Grey.



 

How to join 900/75/50 trunking pieces together (not elbows)

 You need to use a 900CC-WE trunking connector

Can I get a flat elbow for the Clipsal 900/40/25-WE

Yes, part number is 900/40/25E-WE

Does the 900/100/100-GY come with a removeable lid

Yes it does.

Does the Quantum 140ARI03000 module support an type Ni (Nickel) RTD?

Yes, the 140ARI03000 supports Ni 100,200,500 & 1000 RTD's.

Com'X 200 / 210 / 510 Documentation (Technical Datasheet, User Guide, and Installation Guide)

Issue
Documentation for COM'X 200/210/510 is needed

Product Line
Com'X 200 (EBX200)
Com'X 210 (EGX210)
Com'X 510 (EBX510)

Environment
Documentation

Resolution
The documents below include Technical Datasheet, User Manual, and Installation Guide

Com'X 200/210/510 Installation Guide:5406AD002
Com'X 200/210 User Manual: DOCA0036EN
Com'X 510 User Manual: DOCA0098EN
Com'X 200/210/510 Technical Datasheet: PLSED310098EN
 

What are the LEDs indications for Com’X 200/210/510?

Product Line:
Com’X 200
Com’X 210
Com’X 510
 
Environment:
LEDs indications 
 
Resolution:

What fuse is needed to be used with Com'X 200/210/510?

Product Line
Com'X 200 (EBX200)
Com'X 210 (EBX210)
Com'X 510 (EBX510)

Environment
Fuse protection type

Resolution
  • 100-230 V AC option (Com'X 200 only)
    • Fuse protection type T 0.63AE/250V (F1)
  • 24 V DC option
    • Fuse protection type 3.15AL/250V (F1500)
  • Power Over Ethernet (PoE) 
    • No fuse needed

What is the length of the Com'X 200/210/510 External GPRS antenna cable

Product Line
Com’X 200 (EBX200)
Com’X 210 (EBX210)
Com'X 510 (EBX510)

Environment
GPRS communication

Resolution
The length of the cable that comes with Com'X External GPRS antenna (Part# EBXAANT5M) is 5 meters (16 ft)

MultiTech Router Commissioning for Com’X 200/210/510

Issue
Installation of MultiTech rCell Series router for use with Com'X Gateway

Product Line
Com’X 200/210/510

Environment
Power Monitoring Communications

Cause
Documentation needs for MultiTech Router Commissioning

Resolution
The attached document 7EN42-0166-00.pdf describes installation recommendations and how to commission a MultiTech rCell Series router for use with a Com’X gateway.

Polarity of 0-5V Sensor Cable NBCD0001

Issue:

Polarity of 0-5V Sensor Cable NBCD0001

Product Line:

NetBotz

Environment:

NetBotz version 1 and 2
NBCD0001

Cause:

Configuation / connection to 0-5v source.

Resolution:

One end of NetBotz 0-5V Sensor Cable is DIN6 (ps/2) connector, which goes to an external sensor port on 320/420/500 model or Sensor Pod 120. On the other end are 2 wires - the black wire is ground (-); the red is sense (+).

Configuring the Return or Reply Email Address on a Netbotz Appliance

Issue:

Configuring the Return or Reply Email Address on a version 1 Netbotz Appliance

Product Line:

NetBotz

Environment:

NetBotz version 1 and 2

Cause:

e-mail configuration

Resolution:

Many times an smtp relay server requires a valid FROM address in order to send the email. The "FROM" address on the 300, 303, 310, and 400 series appliances is a combination of the Location field and the DNS Domain field, i.e. location@dnsdomain.com. To properly set the "FROM:" address on a 300, 303, 310 or 400 series appliance you need to properly populate the "Location" field and "DNS Domain" fields on the appliance. Follow these instructions to set these fields:

Location: Browse to "Settings, Location" then populate the appliance location field with what should be the part of the return address before the @ sign. Example, for the return email address to be "netbotz-server-room@netbotz.com", I would set the "Location" field to be "netbotz-server-room".

DNS Domain: Browse to "Network, DNS" and set the "DNS Domain" to be the domain name that should come after the @ sign. Using the example above, I would simply make the DNS Domain "netbotz.com".

On a 320/420/500 series appliance, the "FROM" address is set on the "Email Server" configuration screen. Simply go into "Configuration, Email Server" then set the "From" field at the top of that configuration panel with the full email address as you would like it to appear, e.g. netbotz-server-room@netbotz.com.

NOTE: You do NOT need to use the location field & DNS Domain fields on the 320/420/500 appliances.
300, 303, 310 and 400 series appliance are no longer officially supported.

Do APC Network Management Cards (and Network Management Card embedded devices - Rack PDU, etc) support 1000mbps Ethernet connections?


Issue

Do APC Network Management Cards (and Network Management Card embedded devices - Rack PDU, etc) support 1000mbps (AKA Gigabit) Ethernet connections? How about 10000mbps (10GBe connections)?



Product Line
 
  • Network Management Card 1 - AP9617, AP9618, AP9619
Devices with an embedded Network Management Card 1 include (but are not limited to): Metered/Switched Rack PDUs (AP78XX, AP79XX), Rack Automatic Transfer Switches (AP77XX, Environmental Monitoring Units (AP9320, AP9340, Netbotz 200).
  • Network Management Card 2 - AP9630/30CH, AP9631/31CH, AP9635/35CH
Devices with an embedded Network Management Card 2 include (but are not limited to): 2G Metered/Switched Rack PDUs (AP84XX, AP86XX, AP88XX, AP89XX), Certain Audio/Video Network Management Enabled products, Smart-UPS Online (SRT).


Environment
  • 1000mbps/10000mbps (1GB/10GBe) networking environments
  • All firmware versions
  • All serial numbers
     
Cause

Many users are upgrading their networking environments and looking to understand if APC Network Management Card devices support 1GB/10GB Ethernet connections.


Resolution

APC Network Management Card enabled devices support 10/100mbps Ethernet connections. Generally, 1GB Ethernet switches will support 100mbps (either by auto-negotation or configuration modification) but 10GB switches will not. Though, sometimes vendors offer special hardware modules that can provide 100mbps capability for 10GB Ethernet Switches.

It is suggested that users can check the documentation on their networking equipment to find out if the equipment is capable of 10mbps or more commonly 100mbps and how it can be accomplished. If it can, then APC Network Management Cards will operate normally in a 100mbps environment.

 

ETSNZ - Would the BMXFTB2800 be compatible with the following analogue modules? BMXAMI0810 and BMXAMO0410

The BMX FTB 2800 is a Cage Clamp Screw terminal strip 28 points for 8ch Analog INPUT modules and can be used with the BMX AMI 0810.
The BMX FTB 2820 is a Spring terminal strip 28 points for 8ch Analog INPUT modules and can be used with the BMX AMI 0810.

The BMX FTB 2000 is a Cage Clamp Screw terminal strip 20 points and can be used with the BMX AMO 0410.
The BMX FTB 2010 is a Screw terminal strip 20 cir. Points (Square washers) and can be used with the BMX AMO 0410.
The BMX FTB 2020 is a Spring terminal strip 20 points and can be used with the BMX AMO 0410.

BMX AMO 0410 can also be connected to the Telefast module ABE-7CPA21 with the cable BMX FCA 150/300/500.

What are the part numbers for the motor power and encoder connector for Lexium 28 drives?

Customers may wish to build their own cables for use with Lexium 28 and BCH2 motors.

The connector sets are available using the following part numbers.

Motor power connectors:

Motors with flying leads
BCH2*B/*D/*F motors (flange size: 40/60/80 mm) with free leads connection, without brake uses - VW3M5D1A type connector   (sold in lots of 3)

BCH2*B/*D/*F motors (flange size: 40/60/80 mm) with free leads connection, with brake uses - VW3M5D1F type connector.   (sold in lots of 3)

Motors with military type connector
BCH2*H/*M motors (flange size: 100/130 mm) with or without brake uses - VW3M5D2A    (sold in lots of 3)

BCH2*R motors (flange size:180mm) with or without brake uses - VW3M5D2B     (sold in lots of 3)


Motor Encoder connectors:
For BCH2*B/*D/*F motors (flange: 40/60/80 mm) with free leads connection uses - VW3M8D1A    (sold in lots of 3)

For BCH2*H/*M/*R motors (flange: 100/130/180 mm) with MIL connector uses - VW3M8D2A     (sold in lots of 1)



rev 7-19-18



 

COM'X 200/210/510 control power options and power consumption

Issue
Com'X power supply options and the power consumption for each of the options are needed

Product Line
Com'X 200 (EBX200)
Com'X 210 (EBX210)
Com'X 510 (EBX510)

Environment
Power supply

Resolution
  • 100-230 V AC  (±15 %) (This option is only available in Com’X 200)
    • Power consumption: 26 W max
  • 24 V DC (±10 %)
    • ​​Power consumption: 26 W max
  • PoE using Ethernet port 1 (ETH1)
    • ​​Power consumption: 15 W max

MultiTech Router Commissioning for Com'X 200/210/510

Issue
Installation of MultiTech rCell Series router for use with Com'X Gateway

Product Line
Com’X 200/210/510

Environment
Power Monitoring Communications

Cause
Documentation needs for MultiTech Router Commissioning

Resolution
The attached document 7EN42-0166-00.pdf describes installation recommendations and how to commission a MultiTech rCell Series router for use with a Com’X gateway. Here are the content of this document:
  • Saftey Information
    • Important information
  • Safety Precautions
  • Hardware
    • DIN Rail Mounting
    • Power Supply
    • External Antenna
  • Router Configuration
    • Configuring the Router with a PC
  •  Com'X Configuration
    • Connecting the Router to Com'X
    • Configuring Proxy Settings with EBXA-GPRS-SIM SIM Card

Can the EGX400 or ECC21 fiber port connect directly to a gigabit (1000 Mb) network?

Issue:
User would like to communicate with an EGX400 or ECC21 using a gigabit (1000 Mb) fiber network
 
Product line:
ECC21, EGX400
 
Cause:
Customer wanted to know if they can directly connect 1000Mb a gigabit) fiber connection to EGX400 or ECC21 fiber port?
 
Resolution:
Customer cannot connect a 1000Mb fiber connection directly to the ECC21 or EGX400.
As per the ECC21 and EGX400 Installation Manuals, the fiber port is compatible with 100Mb networks only.
If gigabit fiber network connections are needed, a 100Mb multi-mode LC fiber converter will be required. 

Alternately, a gigabit fiber switch with 10/100/1000 copper ethernet connections could be used. In this instance, the fiber would be run to the switch and 10/100 ethernet to the EGX or ECC gateway.
 

Audio Sensor Reading for Version 2 Appliances does NOT Correlate to Decibel Level

Issue:

Audio Sensor Reading for Version 2 and Version 3 Appliances does NOT Correlate to Decibel Level

Product Line:

NetBotz

Environment:

NetBotz Version 2 and 3 Appliances

Cause:

Audio sensor readings information

Resolution:

For NetBotz version 1 (300/300B/310/400) models, each unit (1...11) in Audio task represents 20 dB.

For version 2 (320/420/500) models and version 3 (355/450/455/550/570) models, the audio level (1...100) does not have directed a correlation to a dB level other than the higher the range the higher the dB of the noise detected. This is due to the fact that the NetBotz devices have a Voice Discrimination logic that will focus the sensor listening in a frequency range that alarms produce audio at. Also the configuration of the audio sensors is dependent on the deployment of the devices. Since the audio level being detected is in relation to the location of the device it requires the user to configure the sensor levels thresholds based off of the actual audio alarm levels and compare them to the normal room noise level.

It is very difficult to measure dB since the room environment can have an effect on the noise level. To test audio sensors on NetBotz 320/420/500 appliance, the suggested method for setting audio is to view the audio graph over a period of time to see the bounds to set a trigger for.

What type of 3G modem can my Com'X use?

Issue:
What type of 3G modem can Com'X gateways use?
 
Product Line:
Com’X 200/210/510
 
Environment:
Com’X 200/210/510 with 3G Modem communication 
 

Resolution:
The following 3G modems have been tested and are compatible with the Com'X 200/210/510.
For each modem, refer to the manufacturer's documentation for technical specifications and detailed installation instructions. 

Manufacturer/Model Antenna Notes 
MultiTech MTC-H5  External  Recommended
Connect to the Com'X gateway internal USB port.
This modem must be mounted to the enclosure externally.
Huawei MS2131i-8  Internal  55°C maximum operating temperature
Modem connects to internal USB port and mounts inside the Com'X gateway front door. 
MultiTech MTD-H5  Internal  Connect to the Com'X gateway internal USB port. 
Modem must be extended outside the Com'X gateway front door










 

Back-UPS is detected as an ""Unknown Device"" in Device Manger

Issue:

Back-UPS is detected as an ""Unknown Device"" in Device Manger


Product Line:

All APC Back-UPS UPS utilizing USB communications.


Environment:

All APC Back-UPS UPS utilizing USB communications.



Cause:

If communication between the PC and the USB compatible Back-UPS, is not working properly when the cable is first connected, an ""Unknown Device"" is detected. This problem may be the result of a weak USB receiver on the PC side. If the UPS itself is not detected when the cable is connected (i.e., its not detecting a ""Back UPS Pro 350"", the installation of APC's Power Management Extensions or Powerchute Personal Edition may fail or hang after the setup.exe file is executed.


Resolution:

1. Make sure the UPS and PC are turned on. Disconnect and reconnect the USB cable a few times until the PC detects the appropriate UPS model. Once it
does, continue on with the installation instructions. If this is not successful, go to the next step.


2. Check to see if the Human Interface Device (HID) drivers are already installed. If they are not installed, the Add New Hardware Wizard will not start
up when the USB cable is connected. If the HID drivers are installed, then continue on with the installation of APC's Power Management Extensions
software. To check to see if these drivers are installed go to Device Manager (Start - Settings - Control Panel - System - Device Manager) and look for a
device category called ""Human Interface Device"". If you then unplug the USB cable, this line item will disappear. When you reconnect the cable, the
category will reappear. This confirms that the drivers are properly installed.


3. Confirm that your PC's USB ports are enabled. Go to Device Manager (Start - Settings - Control Panel - System - Device Manager) and look at the list of installed devices.
Towards the bottom, you should see, ""Universal Serial Bus controllers"" and within that you will see, XXX ""Universal Host Controller"" and ""USB Root Hub"".
If Device Manager does not list these items, then your PC is not properly configured to support USB ports. Consult your PC manufacturer for help on this issue.


4. If you are connected through a USB Hub, try connecting the supplied UPS's USB cable directly to a USB port on the PC itself.


5. If other USB devices are connected, try removing those other devices before connecting our USB cable.


6. If possible, try the same installation on another PC or with another UPS.


7. Reboot your PC. After reboot, did your PC recognize the UPS or are you still receiving the initial message of ""Please check that the USB cable between your battery backup and PC is properly connected”? If so, there are a few parameters of your PC’s BIOS that need to be changed in order for your PC to recognize the USB device as an APC UPS after each boot. These changes are as follows:

Advanced Power Management – Needs to be disabled
USB Legacy Device – Needs to be enabled

Note: An APC representative cannot make changes or assist customers in making changes to the BIOS, as it is a liability to APC. The BIOS of your PC is both manufacturer and model specific. Consultation of the Original Equipment Manufacturer is advised in making these changes.


8. If none of the above steps work, please contact APC's Technical Support in the United States and Canada via E-Support at www.apcc/support/contact or via
telephone at 800-800-4272. For support outside of North America, please refer to APC's worldwide contact page at www.apcc.com/contact/#worldwide


Note for Back UPS PRO 350U or 500U users: Compaq Presario Series 5000/5100/5200 computers using non-Intel chip sets have demonstrated unpredictable USB performance with some USB peripherals. APC has developed a special USB connector for these computers which will significantly improve the reliability of USB communications. APC strongly recommends the use of this special connector with Compaq 5000/5100/5200 series computers.


To get your special USB connector shipped to you at no charge, visit the Web at https://promo.apcc.com (key code J421Z). Or you can mail or fax the order form enclosed with you Back UPS Pro 350U or 500U."

Why are there two Ethernet ports on the Com'X 200 / 210 / 510 ?

Issue
The Com'X 200, Com'x 210, and Com'X 510 have two Ethernet ports and a user may be unsure how to use each of the ports.

Product Line
Com'X 200 (EBX200)
Com'X 210 (EBX210)
Com'X 510 (EBX510)

Environment
Com'X 200/210/510 Ethernet Networking

Cause 
A user may be confused about which port to use for an application.

Resolution 
The Com'X features 2 Ethernet ports:

The Ethernet ports can be configured in 2 modes:
     1) Switch mode: in this case both Ethernet ports share a common configuration.
     2) Upstream/downstream mode: both Ethernet ports are configured separately.


1) In switch mode, both Ethernet ports have the same settings. Using 2 ports simplifies wiring:
    -  Ethernet 1 can be connected to a switch on a local network.
     - Ethernet 2 can be used to connect a PC for configuration operations or to connect a data collection device locally with an Ethernet port.

2) In upstream/downstream mode, the 2 Ethernet ports have different settings and function independently:
    - Ethernet 1 must be used for data publishing. It can be also configured in DHCP Client mode or static IPv4 address mode.
    - Ethernet 2 must be used for data collection. It can be configured as DHCP client, static IPv4 address, or DHCP server.

Note: The Com'X can also utilize power over Ethernet (PoE). Ethernet 1 port should be used for PoE.  View the Technical Datasheet attatched for more details.

NetBotz 750 | Physical Description

Issue:
   Physical Description of the NetBotz 750

Product Line:
   NetBotz version 5
      - Rack Monitor 750

Environment:
   NetBotz v5.X

Resolution:

Physical Description



 
Item Description
1 AC line inlet Input power connection.
2 Switched Outlet Provides power to a device at a maximum of 10 A. Activates a connected device when configured events occur. (For example, a fan may be connected to this outlet, and the outlet may be configured to turn on when certain alarms are generated.)
3 A-Link ports Provide communications and power to connected devices (sensor pods, rack access pods, and temperature/humidity sensors with digital displays) over standard CAT-5 cabling with straight-through wiring. For instructions to cascade devices, see the Installation and Quick Configuration Manual.
4 Leak Rope ports Used for connecting a NetBotz Leak Rope Sensor (NBES0308).
5 Rack Access Ports* Ports for the door switch sensors (NBES0302 or NBES0303) and handle sensors (NBHN125 or NBHN1356).
6 Universal Sensor ports Used to connect APC by Schneider Electric sensors, third-party dry-contact sensors, and standard, third-party 0-5 V sensors. Third-party, dry-contact state sensors require the NetBotz Dry Contact Cable (NBES0304), and third party, 0-5 V sensors require the NetBotz 0-5 V sensor cable (NBES0305).
7 Beacon Port Used for connecting an Alarm Beacon (AP9324).
8 10/100/1000 Network Port Provides a connection to the network. Status and link Light-emitting Diodes (LEDs) indicate network traffic. See Link LED and Status LED for additional information.
9 Private LAN Provides a 10/100/1000 connection to a private local area network and 48 VDC to an attached device.
10 Wireless Sensor Coordinator USB Port with Wireless NetBotz USB Coordinator (NBWC100U) installed. Used with wireless sensors.
11 USB Type A Ports Reserved for future use.
12 Modbus RS485 Port Reserved for future use.
13 Voltage Output Provides 12 VDC or 24 VDC (75 mA) to one connected device.
13 Relay Output Used for connecting relay-controlled external devices. Relay Outputs can only be connected to Class 2 circuits.
14 4-20 mA Inputs Inputs for industry standard 4-20 mA sensors.
15 Console Port Provides a serial connection to the appliance.
16 Power LED Illuminates when the unit is receiving power.
17 Reset Switch Reboots the appliance.
18 Exhaust fan Exhausts hot air from the appliance.
*Note supported on firmware version 5.0.1. Update the firmware to access these features.

Video: How do I create a direct connection between a computer and a APC networked enabled product?

Issue
How do I create a direct or one to one connection between a computer and a APC networked enabled product?

Product Line
  • Any network enabled Schneider Electric devices including but not limited to:
    • Network Management Cards (NMC/NMC2)
    • Rack Power Distribution Products (PDU, ATS)
    • KVM Switches
    • NetBotz
    • StruxureWare Data Center Expert Hardware Appliance
 
Environment
  • Situations where it may be necessary to rule out a network problem and directly connect via Ethernet to a device
  • Situations where it may be necessary to directly connect to a device for access when a networking device such as a hub, switch, or router is unavailable to facilitate a network connection
  • Environments where a PC or Mac with available wired Ethernet port is available

Cause

You may run into a scenario in which you or a user believes the Network Management Card (or any other network enabled device) is faulty because it cannot be reached it through the particular network. This is typically a configuration issue or problem with the network. If there are lights on the NMC (or the particular device's) network jack, it is very likely the card itself is operating. Because troubleshooting a customer network issue is typically outside the scope of Schneider Electric technical support, it is technical support's prerogative to prove the Schneider Electric device is functional. We can do this by creating a direct connection between the a user's computer and the NMC (or other device type), which eliminates the particular network as a variable in most, if not all, scenarios. Essentially, we are creating a mini network between the computer and the NMC (or other networked device).

Furthermore, these instructions can be helpful for obtaining logs or data from the network interface of a device if a typical network connection via a hub, switch, or router is unavailable.

Please refer to the instructions below in order to sit up the mini network.


Resolution



Equipment required: 
  • Laptop or computer with 10/100/1000 mbps Ethernet port
  • Serial cable (depends on APC/Schneider Electric product)
  • Crossover cable (or patch cable if computer has 1000 mbps gigabit port)


Steps:
(This example will refer to a Network Management Card (NMC) but the steps are the same for any networked device for the most part).
  • Set the IP address of the NMC to a non-routable network address. For our purposes, we will use 192.168.1.2
  • Set a Subnet mask of 255.255.255.0
  • Set the default gateway of the NMC as the IP address of the computer. For our purposes we will use 192.168.1.3
  • Configure a static IP on the computer in the same network. (In a Windows environment this is typically located under control panel > network connections > Local Area Connection.)
  • Choose properties, scroll down to TCP/IP and choose properties
  • Click the radio box for "Use the following IP address" and enter the IP information. For our example, enter:
    • IP: 192.168.1.3
    • Subnet mask: 255.255.255.0
    • Default gateway: 192.168.1.2 (which is the IP address of the NMC)

Click Ok, then close. The computer will take a second to cycle its network interface to take the new IP settings. Connect the crossover (or straight through, in the case of gigabit) cable.
After completing the above configuration, for our example, we are having the APC device look at the computer as its default gateway and having the computer look at the APC device as its default gateway. In a customer scenario, this should hold true, no matter what IP address scheme they choose to use.

From the computer, you should now be able to ping the IP of the NMC, in our case 192.168.1.2. You can also access telnet or the web interface. This is proof that the NMC's interface is accessible.

Remember that the computer's IP settings will likely need to be reconfigured again to regain normal network communications after testing.

ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List

Issue:
ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List.

Product line:
ACRP1Xx, ACRP5XX, ACRD5XX, ACRC5XX.

Environment:
All Serial Numbers.

Cause: 
Parts.

Resolution:
Please contact Cooling Tech Support to confirm the part numbers before quoting as some may have changed. 888-695-6500 Option 2, Option 2, Option 2
 
Description Part Number Mfg. P/N
     
ACTUATOR - FLOATING 132 IN-LBS W491-0521  
ADPTR ELBOW 1/2 INCH - 15 MM PEX (FOR PIPING - Compression coupling) [PART OF SHIP LOOSE KIT] W875-0989  
ADPTR PIPE 3" ENGL TO METRIC (adapter for connecting to metric pipe) 0M-61194  
ADPTR STRAIGHT 1/2 INCH - 1/2 INCH PEX (Humid & Cond Connections) [PART OF SHIP LOOSE KIT] W875-0991  
ADPTR STRAIGHT 1/2 INCH - 15 MM PEX [PART OF SHIP LOOSE KIT] 875-0989  
ATS - ACRP500 W451-0227  
ATS - ACRP501 W451-0226  
ATS TRANSFORMERS W430-0423  
BALL VALVE, GAS SHUTOFF 3/4" [PART OF SHIP LOOSE KIT] 875-4280  
CABLE ASSY 200V CONTROL JUMPER W0W3109  
CABLE ASSY ACRP CW MAIN CTRL W0W4760  
CABLE ASSY ATS CONTROL - ACRP5xx 208V (CW) (connects TIMERs, CONTACTORs, & CIRCUIT BREAKERs) 0W3103  
CABLE ASSY ATS CONTROL - ACRP5xx 480V  (CW) (connects TIMERs, CONTACTORs, & CIRCUIT BREAKERs) 0W3175  
CABLE ASSY CABLE ATS #1 200-240V 0W3121  
CABLE ASSY CABLE ATS #1 480V 0W3122  
CABLE ASSY FAN GUARD [female to female connector and the rear of the fan grill module] 0W3104  
CABLE ASSY FAN/HTR INTRLK ADAPT - ACRP1xx (DX) (P30A to P5 & P6) 0W3569  
CABLE ASSY FAN/HTR INTRLK ADAPT - ACRP5xx (CW) (P30A to P5 & P6) 0W3568  
CABLE ASSY Humidity Sensor For ACRP 1.6 ft - Spare Part (front) W0N-0297  
CABLE ASSY Humidity Sensor For ACRP 17ft - Spare Part (rear) W0N-0865  
CABLE ASSY TEMPERATURE SENSOR KIT (AT0056GB01 - ACRP ADDITIONAL SUPPLY TEMPERATURE SENSOR) 0N-0933  
CABLE ASSY THERMISTOR/PROBE EMU 1.6 FT (front) 0W3314A  
CABLE ASSY THERMISTOR/PROBE EMU 13 FT (RACK INLET) [PART OF SHIP LOOSE KIT] 0J-0W99952  
CABLE ASSY THERMISTOR/PROBE EMU 8 FT - SPARE PART 0J-0W3163A  
CABLE ASSY THERMISTOR/PROBE EMU 8 FT ASSY (Generic EMU sensor) AP9335T  
Cable Fan To Safety Plug for ACRPxxx (CW AND DX) - Spare Part W0W3105  
Cable for FAN ACRP1xx (DX) - Spare Part (P30 to P101/P100) W0W3118  
Cable For FAN ACRP5xx (CW) - Spare Part W0W3120  
Cable for Reheat ACRP1xx (DX) - Spare Part W0W3117  
Cable for Reheat ACRP5xx (CW) - Spare Part W0W3119  
Cable from Ckt Brk to Reheat/Humidifier for ACRP1xx (DX) - Spare Part W0W3106  
Cable from Ckt Brk to Reheat/Humidifier for ACRP5xx (CW) - Spare Part W0W3107  
Cable Main Power 208/400V For ACRP100/102 (DX) - Spare Part W0W3128  
Cable Main Power 480V For ACRP101 (DX) - Spare Part W0W3127  
Cable Main Power ACRP5xx ASSY ATS 200-240V #2 0W3125  
Cable Main Power ACRP5xx ASSY ATS 400-480V #2 0W3126  
CABLE TIE HNGD FOR HOLE D4.8MM ROHS [PART OF SHIP LOOSE KIT] 820-0048  
CABLE Variable Frequency Drive 200V for ACRP100 (DX) - Spare Part W0W3171  
CABLE Variable Frequency Drive 400V for ACRP101 (DX) - Spare Part W0W3116  
CDU Metric Pipe Connection Kit ACAC20012  
Circuit Board For Compact ACRP100/500 208 VAC 3 Phase - Spare Part (Humid Control Board) W0P2484  
Circuit Board For Compact ACRP101/501 460 VAC 3 Phase - Spare Part (Humid Control Board) W0P2505  
Circuit Breaker 2P 5A 240V Class K -  ACRP500 ATS MONITOR BREAKERS W530-0920 ABB P/N : 2CDS 272 417 R0357
Circuit Breaker 2P 5A 480V UL489 Class K - ACRP501 ATS MONITOR BREAKERS W530-0919 ABB P/N : 2CDS 272 317 R0357
Circuit Breaker 3P 10A 280V Class K -ACRP500/100 HUMIDIFIER BREAKER W530-0917 ABB P/N :  2CDS 273 417 R0457
Circuit Breaker 3P 10A 480V UL489 Class K - ACRP101 ELECTRIC HEATER BREAKER W530-0918 ABB P/N : 2CDS 273 317 R0427
Circuit Breaker 3P 15A 480V UL489 Class K - ACRP501 ELECTRIC HEATER BREAKER W530-0916 ABB P/N : 2CDS 273 317 R0457
Circuit Breaker 3P 20A 240V UL489 Class K -ACRP100 ELECTRIC HEATER BREAKER W530-0915 ABB P/N : 2CDS 273 417 R0487
Circuit Breaker 3P 30A 240V Class K - ACRP500 ELECTRIC HEATER BREAKER W530-0913 ABB P/N : 2CDS 273 417 R0527
Circuit Breaker 3P 30A 480V - ACRP501/101 CB0-A/B INPUT BREAKER W530-0442 ABB P/N : T1N030TL
Circuit Breaker 3P 50A 480V - ACRP501/101 CB0-A/B INPUT BREAKER W530-0445 ABB P/N : T1N050TL
Circuit Breaker 3P 50A 280V TMF ABB T1N -ACRP500 CB0-A/B INPUT BREAKER W530-0445 ABB P/N : T1N050TL
Circuit Breaker 3P 5A 240V Class K - ACRP500/100 FAN / COND PUMP W530-0912 ABB P/N : 2CDS 273 417 R0357
Circuit Breaker 3P 5A 480V Class K - ACRP501/101 FAN / COND PUMP W530-0911 ABB P/N : 2CDS 273 317 R0357
Circuit Breaker 3P 70A 280V TMF ABB T1N - ACRP100 CB0-A INPUT BREAKER W530-0447 ABB P/N : T1N070TL
Circuit Breaker 3P 8A 480V UL489 Class K - ACRP501/101 HUMIDIFIER BREAKER W530-0909 ABB P/N : 2CDS 273 317 R0407
CLAMP DOUBLE SNAP CRIP 27-31MM [PART OF SHIP LOOSE KIT] 875-00009  
Complete 801 PCB CRAC MB - (MB Only) W0P2340  
Complete 805 PCB CRAC 2X DP - (DPS Diff Pressure Card) W0P2354  
Complete 879 PCB XA SIMM - (XAS card) W0P2342  
COMPRESSOR 200V RECIP N-VAR R407C (ACRP100) 208v W875-3801 120B0032
COMPRESSOR 460V RECIP N-VAR R407C (ACRP101/ACRP102) 460v W875-3802 120B0004
COMPRESSOR NOISE COVER (MEETS UL 94 HB) 850-0665A  
Condensate Overflow CLAMP DOUBLE SNAP CRIP 27-31MM 875-00009  
Condensate Overflow HOSE STEAM SUPPLY 7/8ID 660-7002B  
Contactor A26 Coil 200/240VAC 1NO For ACRP500 - Spare Part W451-0046 ABB P/N : 1SBL241001R7510
Contactor, NR 24VAC 16 AMP 1NO - Spare Part (ACRP100 - heater) W451-0141 ABB P/N : A16-30-10-81
Contactor, NR 24VAC 9 AMP 1NO - Spare Part (ACRP101 - both heaters & humidifier; ACRP100 - humidifier) W451-0104 ABB P/N : A9-30-10-81
CPLR HFC35 PIPE THREAD SHUTOFF 3/8 BSPT [PART OF SHIP LOOSE KIT] 875-0978  
CPLR PLC PIPE THREAD SHUTOFF 3/8 BSPT [PART OF SHIP LOOSE KIT] 875-0974  
CRANK CASE HEATER ASSY #1 W0M-9895  
ELBOW ADPTR REDUCTION 1/2 INCH - 3/8 INCH [PART OF SHIP LOOSE KIT] 875-0990  
Fan Module Assembly 200V - Spare Part W0M-9841  
Fan Module Assembly 400-480V ACRP101/501- Spare Part W0M-9848  
FILTER AIR 30% 418X470X96 MM (Standard) 0J-875-2013A  This is a pack of 4 filters
FILTER AIR 85% 418X470X96 MM  (Optional) W875-2014  
Flexible Fluid Piping - 100 Feet (30.4 Meters) ACAC20003  
Flexible Fluid Piping - 300 Feet (91.4 Meters) ACAC20002  
Flexible Fluid Piping Clamp/Hanger ACAC20007  
Flexible Fluid Piping Clamp/Hanger (qty of 50) ACAC20008  
Flexible Fluid Piping Couplings (4 per pack) [875-4308 is the individual pn#] ACAC20006  
Flexible Fluid Piping Couplings FTG PEX 1"NPT with CRIMP [comes in a pack of 4 with pn#ACAC20006] 875-4308  
Flexible Fluid Piping Insulation - 100 Feet (30.4 Meters) ACAC20005  
Flexible Fluid Piping Insulation - 300 Feet (91.4 Meters) ACAC20004  
Flexible Fluid Piping Strut Mounted Clamp ACAC20009  
FLOW METER - 1"  (body of the flowmeter) W875-4018  
FLOW METER ELECTRONIC PIPING FLOW electronics section of flowmeter W0N-0278  
FLOW METER GRUNFOS (new flowmeter) W0N-0303  
Flow meter UNION 1.0" C X NPTI (* send 2 with a flow meter body) 875-0876  
FLTR-DRIER 5/8" ODF SOLDER W875-2012  
FUSE FAST 30A CLASS J 600V CUBEFUSE for Compressor - ACRP101 (DX 400V) W516-0107 BUSSMANN : TCF30
FUSE FAST 60A CLASS J 600V CUBEFUSE for Compressor - ACRP100 (DX 200V) W516-0106 BUSSMANN : TCF60
FUSEHOLDER CLASS J 30-60A 600V CUBEFUSE - ACRP1xx (DX 200/400V) W890-0079 U2-1IGZ/H U2311301
GASKET FOR INROW CW 3-WAY VALVE W875-00012  
HIGH PRESSURE SWITCH ASSY (cuts out at 377psi) W0M-9897  
HOSE STEAM SUPPLY 7/8ID (ordered in feet) [PART OF SHIP LOOSE KIT] 660-7002B  
HUMIDIFIER COMPACT 1-3 KG/H 200 V (humidifier frame) 875-9001  
HUMIDIFIER COMPACT 1-3 KG/H 480 V (humidifier frame) 875-9003  
HUMIDIFIER CYLINDER HOLDING BELT W875-00029  
HUMIDIFIER DRAIN VALVE SLND CAREL 1-1/4 IN W875-4257  
HUMIDIFIER FILL VALVE W875-4233  
HUMIDIFIER HIGH COND. CYLINDER REPLA 1-3KG/H 208V (Standard conductivity 350-1250) W491-0529 BL0TRB00H1
HUMIDIFIER HIGH COND. CYLINDER REPLA 1-3KG/H 480V (Standard conductivity 350-1250) W491-0528 BL0TRM00H1
HUMIDIFIER LOW COND. CYLINDER REPLA 1-3KG/H 208V SPARE PART (Optional conductivity 125-350) W875-00030 BL0TRA00H1
HUMIDIFIER LOW COND. CYLINDER REPLA 1-3KG/H 480V SPARE PART (Optional conductivity 125-350) W875-00032 BL0TRL00H1
HUMIDIFIER Printed Circuit Board For Compact 3 KG/H 400 VAC 3-Phase - Spare Part W0P2504  
HUMIDIFIER Printed Circuit Board For Compact 3 KG/H 208 VAC 3-Phase - Spare Part W0P2484  
KIT DOOR CRV POWERVIEW 42U 600MM SX (BLK KEY) (Rack) W0H-0128  
KIT DOORS SPLIT PERF 42U 600MM BLK SX (Rack) W0H-0042  
LABEL MODEL/ SERIAL # ROHS [PART OF SHIP LOOSE KIT] 885-7015B  
Leak sensor (ships with orange sensor and cable ties; NO BLACK CAT5e CABLE)[ACRP ONLY] AP9326  
Main Control Cable for ACRP1xx (DX) - Spare Part W0W3100  
Main Control Cable for ACRP5xx (CW) - Spare Part (new flow meter) W0W4760 (old flow meter) W0W3101  
MOTHERBOARD SET (MB,WC,XA,DP,OPT)  (Complete Board Assy) W0P2372  
Motherboard Set 1-Bay Board Set (MB,WC,XA,DP,OPT,485-FMTR) - Spare Part (board set for new flowmeter) W0P2860  
NMC with CAN controller - (EMBEDDED NMC) WAP9517CAN  
PCB 808 CRAC 9X RLY 2X OPTO FAN TACH (relay board) W0P2465  
PCB 811 CRAC 8X OPTO SIMM (SIMM Card power control board) W0P2358  
PCB CMS Complete 809 CRAC 3X RS485 SIMM - (CMS power control board) W0P2355  
PCB COMMUNICATION CARD FOR RS485 (Humid Comm Board) W0P2483  
Peristolic Pump (Pump only) 491-0510  
Peristolic Pump Goo (solution-send with the perostolic pump) 491-0511  
PIPE ASSY 6 INLET RECIVER 0M-9815A  
POLY BAG (6" X 9") PA130 [PART OF SHIP LOOSE KIT] 872-9014  
POWERVIEW MP - SPARE PART W0N-0286  
PRESSURE RELIEF VALVE -3/8 MPTX1/2 FLARE 425PSIG (INDOOR) W875-4230  
PUMP CONDENSATE HARTELL 240V * ALL UNITS 200/400/480 W491-0523  
QUICK CPLR HFC35 ELBOW HOSE SHUTOFF 1/2 ID (Internal Connections Condensate to W875-0979) W875-0981  
QUICK CPLR HFC35 HOSE SHUTOFF 1/2 ID (Internal Connections Condensate to W875-0981) W875-0979
QUICK CPLR HFC35 IN-LINE HOSE SHUTOFF 1/2 ID (Condensate Connects to W875-0978) W875-0980
QUICK CPLR HFC35 PIPE THREAD SHUTOFF 3/8 BSPT (Condensate Connects to W875-0980) [PART OF SHIP LOOSE KIT] W875-0978
QUICK CPLR PLC ELBOW MALE 3/8 OD 1/4 ID (Internal Connections Humid to W875-00020) W875-00021
QUICK CPLR PLC PIPE THREAD SHUTOFF 3/8 BSPT (Humid Connects to W875-0976) [PART OF SHIP LOOSE KIT] W875-0974
QUICK CPLR PLC PNL MNT FEMALE 3/8 OD 1/4 ID  (Internal Connections Humid to W875-00021) W875-00020  
QUICK CPLR PLC PNL MNT HOSE SHUTOFF 3/8 OD 1/4 ID (Humid Connects to W875-0974 ) W875-0976  
Reheat Module for 200V ACRP100/500 - Spare Part W0N-0813  
Reheat Module for 400-480V ACRP101/501- Spare Part W0N-0812  
RES CARB FILM 1/4W 5% 120 OHM [PART OF SHIP LOOSE KIT] 110-0121  
ROTO MALE STRAIGHT 1 1/4" - 3/4" SWT - (DX Refrig Supply and Return Connections Internal) 875-4285  
Rotolock Pipe FEMALE ENDCAP 1-1/4" 12 UNF W875-4288  
Rotolock Pipe Female Straight Fitting 1-1/4" - 3/4" SWT - (DX Supply & Return Connection) [PART OF SHIP LOOSE KIT] W875-4286  
SCREW M5 X 10MM TORX W/WASHERS ROHS [PART OF SHIP LOOSE KIT] 803-5531A  
SCREW M6 X 16MM TORX W/WASHERS ROHS [PART OF SHIP LOOSE KIT] 803-0686A  
SCREW M6X12MM TORX W/WASHERS ROHS [PART OF SHIP LOOSE KIT] 803-0684A  
SCREW THFM M6X10MM PN HD TX ZP [PART OF SHIP LOOSE KIT] 803-0660  
Side Panel Assy  42U x 1070mm Blk W0M-5965  
SIGHT GLASS 5/8" ODF SOLDER (Piping) W875-2011  
SOLENOID 24AC COIL 6POSITION PLUG ASSY  (BYPASS) W0M-8204  
SOLENOID COIL ASSY (LL) W0M-9894  
SOLENOID REFRIGERATION VALVE 3/8 875-4196  
SOLENOID REFRIGERATION VALVE 5/8 W875-4282  
STRAIGHT ADPTR REDUCTION 3/8 BSPT-1/2 NPT  (Humid & Cond Supply) 875-4341  
TEFLONRINGS FOR ROTO 1 1/4"  (for suction line at the compressor) [PART OF SHIP LOOSE KIT] W875-4294 compressor
TEFLONRINGS FOR ROTO 1" (for discharge line at the compressor) [PART OF SHIP LOOSE KIT] W875-4291  
TELECOUPLNG 8P8C RJ45 STRAIGHT (ethernet telecoupler) W750-0034  
TEV VALVE, 5/8 IN 7/8 OUT R-407C W875-1001  
TRANSDUCER PRESSURE 2CP5 W875-3400  
TRANSFORMER CLASS II 100VA 208-230-460-480VX24V-30V W430-0197 T30018 Rev C
TYRAP 390MM V0 RATED GT120RV0 [PART OF SHIP LOOSE KIT] 820-0390  
UNION - Ring Seal D35 X 3 - (CW Supply and Return Connections) W875-4298  
UNION 1.0" C X NPTI Gasket 875-0887  
UNION END 1-3/8 ID SWT CW 37 Sleeve Union End (CW Supply and Return Connections) 875-00014  
UNION END 1-3/8 ID SWT HEX (CW Return Connections) 875-00034  
UNION Extension Adapter COPLING 11 NPT 1-3/8 ID SWT (CW Supply and Return Connections) 875-00015  
UNION FITTING 1-1/2'' 11 NPT  (CW Supply and Return Connections) 875-4289  
UNION NOT 1-1/2'' 11 NPSM 1 3/8'' SWT (CW Supply Connections) 875-4292A  
VARIABLE FREQUENCY CONVERTER 11KW 200 V W491-0531  
VARIABLE FREQUENCY CONVERTER 11KW 400 V W491-0530  
VARIABLE FREQUENCY Electrical Board 11KW 200 V (1.07 upgrade) 530-1138A  
WIRE ASSY FM 208V JUMPER 0W2540  
WIRE ASSY FM 208V JUMPER SET W0H-0152  
WIRE ASSY FM 230V JUMPER 0W2541  
WIRE ASSY FM 380V JUMPER 0W2542  
WIRE ASSY FM 400V JUMPER 0W2543  
WIRE ASSY FM 415V JUMPER 0W2544  
WIRE ASSY FM 460V JUMPER [PART OF SHIP LOOSE KIT] 0W2545  
WIRE ASSY FM 480V JUMPER 0W2546  
WIRE CLIP - BLACK AP9335TH [PART OF SHIP LOOSE KIT] 870-13220  
Wire Kit Customer Interface (CW AND DX) - Spare Part W0W3124  
WIRE TIE 8 X 0.1 X 0.06 NYLON 105C ROHS [PART OF SHIP LOOSE KIT] 820-0003A  
ZIP LOCK POLY BAG 3 X 4 [PART OF SHIP LOOSE KIT] 872-0019  
1U Airflow Management Blanking Panel Kit (Qty 2) Black AR8108BLK   
1U 19" Black Modular Toolless Airflow Management Blanking Panel - Qty 10    AR8136BLK  
1U 19" Black Modular Toolless Airflow Management Blanking Panel - Qty 200    AR8136BLK200  
MECH-ELEC INTERLOCK FOR CONT. A9-A40 450-0515  
 
 
 
RC/RP50x CW Supply Piping                                 RC/RP50x CW Return Piping                    RD50x/RP10x DX Supply & Return Piping

 

 