Quantcast

XW+ Automatic Generator Start

XW+ Automatic Generator Start

XW+ Automatic Generator Start

Item Number: 865-1060-01

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Others

Package 1 Height

6 cm

Package 1 Length

26.5 cm

Package 1 Weight

500 g

Package 1 width

21 cm
Show all specifications

Frequently Asked Questions

hide show

Is the new SCP part number 865-1050-01 compatible with all the XW inverter chargers? (Ex. XW4024, XW6048, XW4548)

865-1050-01 SCP Compatibility
The new part number for the system control panel (SCP) is 865-1050-01.
The XW models had a part number 865-1050 but now the SCP is 865-1050-01 and it is compatible with all XW models.

Customer is requesting the utility interactive current for XWs models

Max Sell Amps

Default - 18Amps (865-1010 XW4024) 36Amps (865-1010-01 XW4024)
                27Amps (865-1000 XW6048) 20Amps (865-1005 XW4548) 48Amps (865-1000-01 XW6048)

Range - 0-18Amps (865-1010 XW4024) 0-36Amps (865-1010-01 XW4024)
                0-27Amps (865-1000 XW6048) 0-20Amps (865-1005 XW4548) 0-48Amps (865-1000-01)

Which metrics will be displayed when using the Conext Battery Monitor?

Issue:
Which metrics will be displayed when using the Conext Battery Monitor?

Product Line:
Conext Battery Monitor

Environment:
Any Schneider Electric solar installation

Cause:
Specific metrics aren't outlined on website

Resolution:
The following metrics will be displayed when using the Conext Battery Monitor:

Battery Current
Battery Temperature
Battery State of Charge
Battery Midpoint 1 Voltage
Battery Midpoint 2 Voltage
Battery Capacity Remaining
Battery Capacity Removed

You can find this and other specifications for the device on our website:
https://solar.schneider-electric.com/product/conext-battery-monitor/

What are the firmware requirements for the new XW+ model

Issue
What firmware is required for older accessories to work with the XW+ models

Environment
Situation where an inverter upgrade is done, such as an RMA/Replacement

Product Line
Conext XW+, SCP, AGS, Combox

Cause
XW+ models require a certain level of firmware to the compatible with the SCP, the AGS, and the Combox.

Resolution
XW+ Model Firmware Requirements

1) The XW+ requires an SCP with fw 2.00bn13. All old SCPs in the US distribution center have been re-programmed and changed to part number 865-1050-01
2) The XW+ requires an AGS with fw 3.00bn2. All old AGSs in the US distribution center have been re-programmed and changed to part number 865-1060-01
3) The XW+ requires a Combox with fw 2.00bn656. All old AGSs in the US distribution center have been re-programmed, but the part number remains 865-1058
4) The old XW / CSW and accessories will run fine with the new AGS / SCP

What does the XW+ Welded relay faults mean (F17, F18, F19, F20, F21, F22)?

 Explanation of XW+ welded relay faults

 

If you receive one of the Welded Relay errors on an XW+ Inverter/Charger (F17 through F22), it is possible that one of the AC transfer relays has failed, but in order to rule out wiring errors or improper operation of the AC bypass breakers, you should take the following steps:

 

First, verify that the AC Bypass Breakers are in the OFF position.  If the AC Bypass breakers are switched ON while the Inverter Output breakers are also ON, the XW will sense that an AC voltage source is present on its AC Output terminals and will register one of these faults.
Any outside source of AC presented to the input and output of the XW simulataneously can potentially weld the relay. THIS IS CONSIDERED A MIS-WIRE AND MAY VOID THE WARRANTY. The Power Distribution Panel (865-1015-01) comes prewired for a single XW and has an interlock to prevent both the inverter output breakers and the AC bypass breakers from being in the ON position simultaneously. When installing dual XW units, ensure that the AC breakers and interlock plate (comes with 2nd inverter extension kit Pt # 865-1020) are installed per the installation manual to prevent this issue. Any system with 3 XW units or more must incorporate and external bypass switch.

 

If the AC Bypass Breakers are off, power the inverter OFF at the AC and DC breakers and disconnect the AC wires from the Inverter's AC Out terminals at the inverter itself. Power the inverter back on and see if the fault clears. Have a qualified person measure across the disconnected output wires while either grid or generator power is being supplied to XW input (AC1 or AC2 LEDs blinking or solid). Make sure no AC voltage is measured across the disconnected output wires.

 

If the fault does not clear, it is likely one of the AC Transfer Relays is actually welded closed.  In this case, a replacement of the AC Board will be necessary.  If this was caused by a mis-wire, it will not be covered under warranty. Contact Technical Support at 866-519-1470 for more information regarding parts and availability..

 

 

What are the part numbers for the red and green LEDs used on the S-Flex Enclosed Drives?

Issue:
Part numbers for the red and green LEDs used on the S-Flex Enclosed Drives

Product Line:
S-Flex 212 and 21

Environment:
All

Cause:
Replacement green and red leds.

Resolution:
Spare Light part numbers:
80462-110-01 Red Led
80462-109-01 Green Led

See table on page 101 of the attached S-Flex Manual.

Show More