Image of 752/WP sensor, pir, wall

C-Bus Occupancy Controller Range, Wall Mount Pir Motion Detector, 110 Degree

Catalogue Number: 752/WP
Image of 752/WP sensor, pir, wall
Retail
$277.24
RRP (Inc. GST)

Specifications

hide show
Range of product
C-Bus
Range
C-Bus
Product brand
Clipsal
[Us] rated supply voltage
24 V DC
Network type
DC
Output current
<= 280 mA
Package 1 Weight
0.3 kg
REACh free of SVHC
Yes
EU RoHS Directive
Compliant
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
ENVEOLI121002EN

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Leaflet

  • Installation Instruction

  • End of Life Manual

  • Specifications

  • Corporate Marketing

Frequently Asked Questions

hide show

Does the 752/CD sensor need extra control gear?

This sensor is for use with a C-bus system.
For a stand alone 240V version you would need the 752/CD1RC.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=752/CD1RC
 

Which occupancy is C-Bus compatible?

Part number 752/CD  is C-Bus compatible.

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=752/CD

User-added image

What is the part number for the hinge section on the 750WP range?

The part number is 750-KNUCKLE-GY.

Which outdoor sensors have a sensitivity adjustment

The  part codes are  100SA360, 750WP and 750WPR

Can 750WP be connected in parallel to control the same load .

No. Need to use the 750WPR, three wire device when connecting in parallel
For more information on the 750 series please visit the Clipsal web site on the link provided . https://www.clipsal.com/Trade/search-results?q=750w

Does the 96VH110/2 have a sensitivity adjustment

No it does not only the 100SA360, 750WP and 750WPR do

Can the 750WP sensor supply LED's?

The 750WP was not tested on LED loads, however a Load correction device may be used in conjunction for LED lighting loads. Load correction device part number = S31LCDA
Also check what LED driver is being used.

Can you get the bit that goes between the base and the sensor on the 750WP

The part number is 750-KNUCKLE-GY
 

Can the 750WP be used with LED lamps?

The 750WP is not compatible with electronic transformers, so can not be used for LED lights.

However, the 750WPR can be used to control LED lights.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=750WP
 

How do I know if 750WPR Infrascans I have installed are affected by the batch related component issue?

If movement is still being detected (shown by the flashing RED LED indicator behind the sensor lens), however the load does not switch on, then the unit is affected. If this is the case please contact the Clipsal warranty department using the link to have the unit replaced free of charge.
Link: https://www.clipsal.com/warranty
 

What is the part number for the load correction device for the 750WP?

The part number for the load correction device for the 750WP is - 31CAP

 

Can you have multiple 750WP 2 wire sensors wired in parallel?

No, unfortunately you will need the 3 wire version. The part number for a 3 wire sensor is 750WPR.
Some of the key features are:
 

  • 10A maximum load current
  • Stand-by power consumption is less than 1W
  • 3 Wire
  • Neutral required
  • 30 seconds warmup time
  • 18 metre radius x 110° rated detection field at maximum sensitivity
  • 5 seconds to 20 minutes timer delay range
  • Cables accommodates 4 terminals, up to 2 x 2.5mm² cable per terminal
  • Relay switching method

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=750WPR

 