Image of 751R Indoor Infrascan 3 Wire 10A with Relay

Motion Infrared Sensor Sensor, 10A, 3 Wire, Indoor

Catalogue Number: 751R
Image of 751R Indoor Infrascan 3 Wire 10A with Relay
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE

Specifications

hide show
Range
Infrascan
Product brand
Clipsal
Product or component type
movement sensor
Device application
lighting
Sensor type
PIR
Product specific application
staircase monitoring
[Ue] rated operational voltage
200...265 V AC
Network frequency
50 Hz
Inrush current
10 A
Power range
<= 2300 W
Protection type
creep zone protection
Function available
automatic with manual override
Movement detection area
12 m
Horizontal detection angle
0-120 °
Time delay range
0...5 s (switch-on)
Duty cycle
20 min
Detection face
  • lateral: 6 m
  • frontal: 6 m
    • Material
      plastic
      Mounting support
    • ceiling
    • wall
      • Mounting height
        2.4 m
        IP degree of protection
        IP20
        Ambient air temperature for operation
        0-40 °C
        Environmental health and issues
        halogen free
        EU RoHS Directive
        Compliant
        Toxic heavy metal free
        Yes
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
         Pro-active China RoHS declaration (out of China RoHS legal scope)
        Circularity Profile
        ENVEOLI121002EN

        Frequently Asked Questions

        hide show

        Can more than one 751R , be used to control the same load?

        Yes , the 3 wire 751R can have more than one unit controlling the same load...
        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=751R

         

        What is the part number for an IP rated sensor similar to 751R?

        The part number for an IP rated sensor similar to 751R is 753SSR - this is 360 degree sensor

        For further information please visit: https://www.clipsal.com/Trade/Products/ProductDetail?catno=753SSR

        User-added image

        What is the part code for a front part only for a CBUS infrascan CBUS2

        The part code is 5751L is the CBUS version of 751R

        Which motion sensors have ESS approval?

        750WPR is ESS approved.

        Does the timer reset, within the time limit, after first being triggered on a 751R?

        Yes, the timer restarts every time it senses movement.

        For more information, please refer to the link:
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=751R 




         

        Can a 753 sensor be used with fluro's and electronic ballasts

         No use the 753R

        Will the 753R sensor compatible with LED's?

        Yes the 753R sensor is compatible with the following loads:

        1. Incandescent
        2. Halogen
        3. Fluorescent
        4. Iron Core Transformers
        5. Electronic Transformers
        6. Small Motor Loads

        Is a mask available for part number 753R?

        The Part number for the mask is 753MASK-WE.

        Is cover available for part number 753R?

        No.Cover is not available for this part.

        Do you do a 753R 360 degree sensor that has a timer of 1 hour?

        No, unfortunatley this part is no longer available and we have no direct alternative.

        For further information please visit https://www.clipsal.com/Trade/search-results/sensor.

        Can the sensor 753R be overridden?

        Yes its not so much wheteher the sensor can do it its more the way its wired you will need an extra switch wire and a 3 position switch "SENSOR, OFF, ON" the part number for that switch mech is 39MSON.

        Will the timer on a 753R reset when someone is in the room?

        No. The 753R will continue to keep lights on in a room, aslong as there is movement which the sensor can detect.
        Once the room is empty the timer will then engage and eventually turn off, depending on your timer configuration.

        Can I adjust the 753R to operate day and night?

        Yes, if you turn the light level adjustment down to the " - " it will work both day and night.

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=753R

        Which 751 infrascan , can use 2 units to control the same load??

        751R-WE

        Does 753R have sensitivity adjustment ?

        Unfortunately not, 753R does not have a sensitivity adjustment. Alternatively we have 753CF1 which has sensitivity adjustment.

        Sensitivity adjustment controls the detection range and sensitivity of 753CF1 sensor. If set to the maximum position, the detection range is Ø7 m @ 2.5 m height.
        If set to the minimum position, the detection range is Ø2 m @ 2.5 m height.
        For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=753CF1

        Can a 751 be used with 25W LED?

        Yes, it can but you will need to put a 31CAP in parallel with the load.

         

        External Antennas for GPRS Cards for WallBotz 500

        Issue:

        External Antennas for GPRS Cards for WallBotz 500

        Product Line:

        NetBotz

        Environment:

        NetBotz NBWL0500

        Cause:

        Supported Accessories

        Resolution:

        Option offers an external antenna for the Globetrotter cards:
        https://eshop.option.com/product.asp?product=OI-ANT-EX-WAPI


        SierraWireless supports external antennas via an adapter that they sell:
        https://mycusthelp.com/sierrawireless/FILEXFER/issue_207/External%20antennas.doc
        https://www.sierrawireless.com/eStore/product.asp?SKU=6000072&CID=1&tgl=yes

         

        What is the minimum load on a 753 sensor?

        The Standard 753 2 wire sensor has a 40W minimum load.
        The 753R 3 wire sensor has no minimum load.

        Can the sensor 753R be overridden?

        Yes its not so much wheteher the sensor can do it its more the way its wired you will need an extra switch wire and a 3 position switch "SENSOR, OFF, ON" the part number for that switch mech is 39MSON.

        How do I enable Telnet on a version 2 or 3 NetBotz appliance?

        Issue:

        Enabling Telnet on a version 2 or 3 NetBotz appliance

        Product Line:

        NetBotz

        Environment:

        NetBotz version 2 and 3

        Cause:

        Alternate configurations

        Resolution:

        Telnet is disabled on a Version 2 and 3 NetBotz Appliances by default, and in order to turn it on use the following procedure.

        To enable telnet temporarily, simply type in the following URL in a web browser:
        https://ip-of-appliance/enabletelnet

        To disable telnet, simply type in the following URL in a web browser:
        https://ip-of-appliance/disabletelnet

        Upon reboot, the appliance will disable telnet again, in other words, it`s not a persistent setting.
         

        Supported PCMCIA Modem Cards for WallBotz 500

        Issue:

        Supported PCMCIA Modem Cards for WallBotz 500

        Product Line:

        NetBotz

        Environment:

        NetBotz 500

        Cause:

        Supported Accessories

        Resolution:

        The part number (from Intel) for the only 500-supported modem pc card is CM-56G:
        https://www.intel.com/network/connectivity/emea/eng/products/xircm56g.htm


        There are some combo cards (10/100 Ethernet + modem) with similar names (i.e. Xircom CreditCard xxxxxxx), and they are NOT supported by WallBotz500.

        Where should the Load correction devices 31CAP and S31LCDA be used?

        The 31CAP is to be use with the following two wire products
        Infrascan 750WP, 751, 753.
        Timer 31VETR
        Sunset Switch WS226SSR/2, 56SSR/2, 31VSSR/2

        The S31LCDA is suitable for use with Clipsal & Schneider Electric 2-Wire, mains powered Dimmers that use
        Leading Edge, Trailing Edge and Universal Dimming.
        Other Suitable loads: Dimmable CFL/ Dimmable LED with Electronic control

        (Load correction Devices may not correct all problems)
        Installation Instructions can be found on the Clipsal.com Website.
         

        Can multiple 753R 360 degree sensors be used on the same circuit?

        Yes they can providing they are the 3 wire design.

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=753R

        What is the cut out size for the Clipsal , 360° Infrascan® Passive Infared Motion Sensor?

        The cut out size is 50mm, please see the attached installation sheet for further detail.

         

        What is the cut out dimensions for 753R?

        The cut out dimensions for the 753R is - 50mm

        For further information , please visit link below:-
        https://www.clipsal.com/Trade/search-results?q=753R

        User-added image

        What is the cutout dimensions for a 753?

        Cutout dimensions for 753 and 753r is 50mm.

        Please follow link below for installation instructions
        https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001475.pdf

        What is the IP rating of 753 and 753R, 360 degree flush mount PIR motion sensor?

        753 and 753R does not have an IP rating. They are designed for indoor use. 753 is a 2-wire (does not require Neutral connection), and can only switch a
        limited range of load types. 753R is a 3-wire device (requires Neutral connection to operate) capable of switching a wide range of load types.
        For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001475.pdf

        User-added image

         

        What is the part number for the 360 degree flush mount infrascan?

        The part number for the 360 degree flush mount infrascan are
        753 .... its a 2 wire device
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=753

        753R ... its a 3 wire device
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=753R

        User-added image
         

        Can the 100CF360 be fitted with an override?

        Unfortunately no, the 100CF360 is not able to be overridden by a wall switch.

        However the 753 & 753R is able to be overridden.

        For information on the 753 & 753R, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=753R
        User-added image

        Standard Lens Specifications for the WallBotz 500 & Camera Pod 120

        Issue:

        Standard Lens Specifications for the WallBotz 500 & Camera Pod 120

        Product Line:

        NetBotz

        Environment:

        NetBotz 500 / Camera pod 120 (Owl 1 pod only)

        Cause:

        Lens specifications.

        Resolution:

        Lens Specifications for the standard lens on the WallBotz 500 / Camera Pod 120 (Owl 1 pods only)
        Manufacturer: Marshall Electronics
        Model: V-4508
        Size: 1/2 inch format
        Focal Length: 8mm
        Note: The focal length distance between the lens and the imager. F-Stop: 1.3
        Note: The f-stop affects depth of field, or how much is in focus in front of and behind the subject.
        Field of View (horizontal x vertical in degrees): 40x28

         

        How Do I Eliminate Multiple Alert Notifications

        Issue:

        Eliminating Multiple Alert Notifications from NetBotz appliances

        Product Line:

        NetBotz

        Environment:

        Potentially any version

        Cause:

        Potentially, different configuration options may cause repeated alerts.

        Resolution:

        - Check that each alert action associated with an alert sequence does not have duplicate addresses associated with it.
        - Verify that the different alert sequences within a profile is not set up with the same notifications.
        - Thresholds may have a threshold specific e-mail address associated with it. Make sure this is not a duplicate of an address already associated with the actions.
        - Make sure the threshold is not set up so that the threshold itself is switching into and out of alert too frequently.
        - Increase the notification interval or decrease the number of notifications in the Alert configuration / profile
        - Maks sure the check box is unchecked for"Automatically add new alert actions to this schedule" for any alert profile sequences.
         

        Why are my lights flickering on a 751 sensor?

        Generally it is because 1 of 2 reasons, Incompatible load type or your not exceeding your minimum load.
        Please see table below for specifications:
         
        Catalogue Number 751 751R
        Minimum Loads 40W 0W
        Compatible Load types Incandescent Incandescent
          240V Halogen 240V Halogen
          Iron Core Transformers* Iron Core Transformers
            Fluorescent
            Electronic Transformers
             
        Incompatible Loads Fluorescent N/A
          Electronic Transformers N/A
          Small Motor Loads 5A Max N/A
          Dischharge Lamps N/A

        For further information please visit Trade - Clipsal by Schneider Electric

        Why the LED light for a combination of a 753 with LED light strobes, when the sensor switches off? Is there a solution to fix this problem?

        Yes there is a solution. Try the following:

        Option1: You will need to change your 753 to a 753R
        Option 2: use a 31CAP, 31LCDA, or add a relay.

        This is a compatibility issue between our sensor and some other company's LED lighting.
        This solution will work 95% of the time but not always.
        For best results you need to use Clipsal LED lights.

        For more information on our sensors visit the website at www.clipsal.com/Trade/search-results and click on the link to view a brochure.

        What is the IP Rating for the motion sensor 753R?

        The IP Rating for the sensor 753R is IP20.
        Some of its key features are:
        • 10A maximum load current
        • Stand-by power consumption is less than 1W
        • 3 Wire
        • Neutral required
        • 30 seconds warmup time
        • 360°, circular detection field 14m diameter rated detection field at maximum sensitivity
        • 5 seconds to 20 minutes timer delay range
        • Cables accommodates 4 terminals, up to 2 x 2.5mm² cable per terminal
        • Length of sensor 141.5mm
        • 72mm Diameter
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=753R
         

         

        What type of loads are compatible with 753 & 753R PIR motion sensor?

        Please refer to the below chart for load compatibility of a 753 and 753R motion sensor.

        For further information please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001475.pdf
        User-added image
         

        Why wont my 751 passive infrared sensor work, it has a 20W flood light wired to it?

        The reason why the light/ sensor wont operate as deisred is because the minimum operating load is 40W. Due to the design of this sensor it is only capable of a maximum of 2 Amps and a minimum of 40W. It also has a maximum off-state leakage current of 5mA.
        If any of these values are exceeded this may casue the system not to work.

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=751
         

        Is there a recessed wall mount sensor?

        No unfortunately we do not offer a recessed sensor. However we can offer a Surface mount sensor, part number 751R.
        Some of the key features are:
        • 10A maximum load current
        • Stand-by power consumption is less than 1W
        • 3 Wire
        • Neutral required
        • 30 seconds warmup time
        • 6m x 6m, 8.5m from sensor head, head rotatable through 120° rated detection field at maximum sensitivity
        • 5 seconds to 20 minutes timer delay range
        • Cables accommodates 3 terminals, up to 1 x 2.5mm² cable per terminal
        • Length of sensor 57mm
        • 100mm Diameter

        For furthur information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=751R

        OR 

        See the attached installation instructions.

        What adjustment options are available on 753 and 753R, 360 degree indoor passive infrared motion sensor?

        753 and 753R has the below adjustments:
        Time-On Adjustment:
        Adjustment Range: Five seconds to 20 minutes. Rotate clockwise to set required time-out period.

        Light-Level Adjustment:
        Adjustment Range: One lux to full sunlight. Rotate clockwise to avoid having load activated when natural light is adequate.

        For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001475.pdf