Key Features & Specifications

hide show
  • 5A maximum load current
  • 10mA maximum off-state leakage current
  • Stand-by power consumption is less than 1W
  • 2 Wire
  • 30 seconds warmup time
  • 18 metre radius x 110° rated detection field at maximum sensitivity
  • 5 seconds to 20 minutes timer delay range
  • Cables accommodates 4 terminals, up to 2 x 2.5mm² cable per terminal
  • Triac switching method
Range of product
Infrascan
Range
Infrascan
Product brand
Clipsal
Product or component type
movement sensor
[Ue] rated operational voltage
200...265 V AC
Network frequency
50 Hz
Power range
<= 40 W
Mounting support
  • wall
  • ceiling
    • Mounting height
      2.4 m
      IP degree of protection
      IP66
      Ambient air temperature for operation
      0-50 °C
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Circularity Profile
      ENVEOLI121002EN

      Frequently Asked Questions

      hide show

      What is the part number for the hinge section on the 750WP range?

      The part number is 750-KNUCKLE-GY.

      Which outdoor sensors have a sensitivity adjustment

      The  part codes are  100SA360, 750WP and 750WPR

      Can 750WP be connected in parallel to control the same load .

      No. Need to use the 750WPR, three wire device when connecting in parallel
      For more information on the 750 series please visit the Clipsal web site on the link provided . https://www.clipsal.com/Trade/search-results?q=750w

      Does the 96VH110/2 have a sensitivity adjustment

      No it does not only the 100SA360, 750WP and 750WPR do

      Can the 750WP sensor supply LED's?

      The 750WP was not tested on LED loads, however a Load correction device may be used in conjunction for LED lighting loads. Load correction device part number = S31LCDA
      Also check what LED driver is being used.

      Can you get the bit that goes between the base and the sensor on the 750WP

      The part number is 750-KNUCKLE-GY
       

      Can the 750WP be used with LED lamps?

      The 750WP is not compatible with electronic transformers, so can not be used for LED lights.

      However, the 750WPR can be used to control LED lights.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=750WP
       

      My 750WPR Infrascan has stopped switching the light on, but the red LED in the sensor is still flashing. What do I do?

      If installed within the last five years it is covered under warranty. Please contact the Clipsal warranty department using the link to have the unit replaced free of charge.
      Link: https://www.clipsal.com/warranty
       

      How do I know if 750WPR Infrascans I have installed are affected by the batch related component issue?

      If movement is still being detected (shown by the flashing RED LED indicator behind the sensor lens), however the load does not switch on, then the unit is affected. If this is the case please contact the Clipsal warranty department using the link to have the unit replaced free of charge.
      Link: https://www.clipsal.com/warranty
       

      What is the part number for the load correction device for the 750WP?

      The part number for the load correction device for the 750WP is - 31CAP

       

      Can you have multiple 750WP 2 wire sensors wired in parallel?

      No, unfortunately you will need the 3 wire version. The part number for a 3 wire sensor is 750WPR.
      Some of the key features are:
       

      • 10A maximum load current
      • Stand-by power consumption is less than 1W
      • 3 Wire
      • Neutral required
      • 30 seconds warmup time
      • 18 metre radius x 110° rated detection field at maximum sensitivity
      • 5 seconds to 20 minutes timer delay range
      • Cables accommodates 4 terminals, up to 2 x 2.5mm² cable per terminal
      • Relay switching method

      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=750WPR

       

      How do I know if I my stock of the 750WPR-GY Infrascan is possibly affected by the recent batch related component issue?

      Check the manufacturing date code on the bottom of the unit box or on the label under the mounting base. Products manufactured after May 2017 are not affected and are ok to use. If you have stock manufactured prior to this date, we are happy to provide free of charge replacements through our warranty process, by contacting Customer Care on email : CustomerCare.AU@schneider-electric.com or Telephone: 137328

      Regarding the recent batch related component issue on the 750WPR Infrascan. I have installed a 750WPR Infrascan several months ago and its working fine so far, do i need to go back to replace it?

      No. Units only need to be replaced IF they become defective. If within 5 years from install the unit does however become defective, please contact the Clipsal warranty department using the link below to have the unit replaced free of charge.
      Link: https://www.clipsal.com/warranty
       

      How do i stop my LED Flood light from flashing when connected to my 750WP 2-wire Sensor?

      The LED Light is not working correctly with 750WP 2-Wire Sensor because it is NOT a compatible load.
      If controlling a LED load via a sensor is required, you will need to use a 3-Wire version. The part number for a 3 Wire version is a 750WPR.
      Please see the compatibility chart below:
      Catalogue Number 750WP 750WPR
      Compatible Load Types Incandescent Incandescent
        240V Halogen 240V Halogen
        Iron Core Transformers Fluorescent Loads
        N/A Iron Core Transformers
        N/A Electronic Transformers
        N/A Shaded Pole Induction Motors (Exhaust fans, (5A Max)
        N/A Split Phase Induction Motors (ceiling fans, 5A Max)
        N/A Other Motor Loads (Limit to 5A Max)
      Incompatible Load Types Electronic Transformers N/A
        Fluorescent Loads N/A
        Discharge Lamps N/A
        Motor Loads N/A

      Some of the key features for the 3 wire 750WPR Outdoor sensor are:
      • 10A maximum load current
      • Stand-by power consumption is less than 1W
      • 3 Wire
      • Neutral required
      • 30 seconds warmup time
      • 18 metre radius x 110° rated detection field at maximum sensitivity
      • 5 seconds to 20 minutes timer delay range
      • Cables accommodates 4 terminals, up to 2 x 2.5mm² cable per terminal
      • Relay switching method
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=750WPR

      Why is LED Light not working correctly with 750WP?

      The LED Light is not working correctly with 750WP 2-Wire Sensor because it is not a compatible load.
      If controlling a LED load via a sensor is required, you will need to use a 3-Wire version. The part number for a 3 Wire version is a 750WPR.
      Please see the compatibility chart below:
      Catalogue Number 750WP 750WPR
      Compatible Load Types Incandescent Incandescent
        240V Halogen 240V Halogen
        Iron Core Transformers Fluorescent Loads
        N/A Iron Core Transformers
        N/A Electronic Transformers
        N/A Shaded Pole Induction Motors (Exhaust fans, (5A Max)
        N/A Split Phase Induction Motors (ceiling fans, 5A Max)
        N/A Other Motor Loads (Limit to 5A Max)
      Incompatible Load Types Electronic Transformers N/A
        Fluorescent Loads N/A
        Discharge Lamps N/A
        Motor Loads N/A

      Some of the key features for the 3 wire 750WPR Outdoor sensor are:
      • 10A maximum load current
      • Stand-by power consumption is less than 1W
      • 3 Wire
      • Neutral required
      • 30 seconds warmup time
      • 18 metre radius x 110° rated detection field at maximum sensitivity
      • 5 seconds to 20 minutes timer delay range
      • Cables accommodates 4 terminals, up to 2 x 2.5mm² cable per terminal
      • Relay switching method
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=750WPR



       

      Will a 2-wire Infrascan 750WP Sensor operate with 20W load?

      No, Unfortunately a 20W load will not operate a 2-wire Infrascan 750WP Sensor as it has a minimum load of 40W. You can increse the minimum load by adding multiple lights or a larger light. Alternatively you can install a product called a 31CAP which is a capacitor specifically designed to "increase" the minimum load. 

      The characteristics of a 31CAP capacitor are:
      Values Description
      Amp 0.025A (Ampere)  =  25mA (Milliampere).
      Watts 6W
      Voltage 240V
      Microfarad 0.33μF
      Maximum amount stacked in parallel 3

      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=31CAP