Frequently Asked Questions

hide show

Is there a white cover plate available for the PDL vertical double socket outlet with extra switch - 692X?

The PDL 692XC is the cover plate to suit.
 

Is the PDL 695X available in 15A version?

No, we have no 15A sockets available with an extra switch.

Is there a PDL 695 with neon in middle

You can purchase PDL 695X and the pdl indicator module that is required

Is there a Surge Protection Socket Outlet available in the 600 series?

PDL used to do a complete unit - The 695SP however, this is now obsolete. A Surge Protection Outlet can be made up of parts. You will need to use one of the sockets that have an extra switch space such as the 694X or the 695X and replace the extra switch with our Surge Protection Module, the 600SM.

 

What is the part code for a Surge protection outlet in 15A

You can plate mount a surge module PDL600SM into any 600 series aparture that could be a 681VH plate or a 695X

Is it possible to get the PDL 695R (10A Horizontal double, switched socket with Round Earth Pin) in black?

No, the complete unit does not come complete in black. However, you can purchase the PDL 695C in black (BK) and swap the cover plates over.
But the Sockets and the switches will still be white.
 

Can you put a 642MUSB USB mech into a double socket plate, eg 695X ?

Yes as of December 2015 the 642MUSB mech can be installed into the extra mech position of the 692X or 695X
This is also available as complete units:
PDL695USBWH
PDL692USBWH

Is the PDL694XX available in black?

No, only available in white

Is the PDL 695RCD double pole switched?

Yes, Double pole switching protects against faulty wiring.

Is there a socket eg. PDL 695WH with a USB charging jack in it as well

Yes, You can use the PDL695X and install a PDL694MUSB in place of the extra switch.

will a PDL642MUSB mech fit into the pdl692xbk Socket outlet?

Yes the 642MUSB mech will fit a 692X. Wire the Active and Neutral into USB mech.

 

Is the PDL 694X, socket outlet horizontal and switched with an extra switch, available in black?

No, the PDL 694X is only available in white
 

Is there a white cover plate available for the PDL 694X?

Yes, the cover plate code is PDL 694XCWH. The cover plate is also available in Polished Brass (694XMPB), Brushed Bronze (694XMBBZ) and Stainless Steel (694XMSS).

 

What does "63.8" on the back of a 3720 ACM mean?

Some older 3720 used to use "63.8" as an ordering option which referred to a 69VAC measurement system.


  • Public

    All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL187974 V1.0, Originally authored by KBAdPM on 09/08/2007, Last Edited by KBAdPM on 09/08/2007
Related ranges: 3720 ACM

Is it possible to get a vertical single, switched socket with two extra switches in the PDL range?

We only do a horizontal single, switched socket with two extra switches - PDL 694XX.

Another alternative would be to use a PDL 691X. This is a vertical single, switched socket with one extra switch.
 

How do I know what the default IP address is for a Twido controller?

The default IP address is 85.16.x.y, where x.y is derived from the last two octets of the MAC address converted to decimal.
Example:
If the MAC address is 00.80.F4.81.45.22, the last two octets is 45.22. These must be converted to decimal. 45hex = 69dec and 22hex = 34dec.
Therefore, the default IP address would be 85.16.69.34

 

How do I troubleshoot the Altivar Process Drive when it will not connect or communicate while over a Modbus Serial Network?

Issue:
How do I troubleshoot the Modbus Serial on the Altivar Process Drive?

Product Line:
Altivar Process Drive (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)

Environment:
All serial numbers for Altivar Process Drive

Cause:
N/A

Resolution:

Note: This FAQ goes over some basic checks and troubleshooting tips. For extended troubleshooting please refer to your drives Modbus Serial manual. 

Drive Will Not Connect
  • Installation
    • Make sure Modbus cable (not Ethernet cable) is connected to the appropriate Modbus serial port.
    • Pin Layout - Make sure to use proper pinouts
    • Isolate any electrical interference
      • Use conduits
      • Separate control and power connections
    • Add terminating resistors if the drive is at the end or the last of device in the network.
    • Network
      • Check for any duplicate addresses on the network.
      • Check to make sure you have proper configured assemblies
    • Programming
      • Check Basic Settings on the drive. Make sure the following is set:
        • Modbus Address
        • Modbus Baud Rate
        • Make sure drive is power cycled after any Communication settings are made.
    • Troubleshooting
      • Check LEDs on the drive
      • The following figure describes the LEDs status for Modbus Field-bus monitoring:
      • Eth NS (Embeded Modbus) - Indicates the Modbus serial link connection status​
Drive Connects But Will Not Run
  • Network
  • Programming on the Drive
    • Confirm drive is setup for Network Control
      • Check Command and Reference Menu
        • [Complete settings] [Command and Reference]
  • ​​Troubleshooting
    • Check Communication Map
      • [Display] [Communication map]
        • ​​Check Command Channel
        • Command Register
        • Ref Freq Channel
        • Ref Freq
  • Reference attached manuals for further troubleshooting