Oven Switch 32A

White | Oven Switch 32A

Oven Switch 32A

Item Number: 680-WH

Retail
$50.52
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

PDL 600 Designer Series

Product brand

Clipsal

Physical

Device presentation

basic element with full cover plate

Actuator

rocker

Number of rocker

1

Number of poles

1

Device mounting

flush

Fixing mode

by screws

Local signalling

without

[Ue] rated operational voltage

240 V AC

Rated current

  • 32 A
  • 25 AX, fluorescent lamp
    • Marking

      without marking

      Standards

    • AS 3100
    • AS 3133
      • Others

        Package 1 Weight

        0.1 kg
        Show all specifications

        Frequently Asked Questions

        hide show

        Are EasyPact MVS circuit breakers for sale in the USA or Canada?

        Issue:
        Where can I buy a EasyPact MVS breaker?

        Product Line:
        EasyPact MVS circuit breakers

        Resolution:
        There are no plans for a general release of the EasyPact MVS circuit breaker line in the US.
         

        Do we have Seismic ratings for our IEC D and F line contactors?

        Issue:
        Seismic ratings for TeSys D and F line contactors
         
        Product Line:
        IEC contactors and starters
         
        Environment:
        Tesys D and Tesys F
         
        Cause:
        application requirement, product ratings
         
        Resolution:
        No, our switching and controlling product does not have any seismic certification or rating.
         
        Generally, customers using our product in seismic applications, are concerned by shock
        and vibration resistance. The Shock and Vibration data are provided in the technical section
        of our catalogue when they are available. See the link below for our current catalog. 

        https://products.schneider-electric.us/technical-library/?event=detail&oid=09008926800a8dbe&cat=0b00892680101a33
         
         

        Are there Seismic ratings for the enclosed TeSys D starters?

        Issue:
        Do we have Seismic ratings for our IEC LE1D contactors and starters?
         
        Product Line:
        IEC enclosed contactors and starters
         
        Environment:
        Tesys LE1D
         
        Cause:
        application requirement, product ratings
         
        Resolution:
        No, our LE1D switching and controlling product does not have any seismic certification or rating.
         
        Generally, customers using our product in seismic applications, are concerned by shock
        and vibration resistance. The Shock and Vibration data are provided for the contactor only. 
        That information is in the technical section of our catalogue when they are available.
        See the link below for our current catalog. 

        https://products.schneider-electric.us/technical-library/?event=detail&oid=09008926800a8dbe&cat=0b00892680101a33
         
         

        What basic parameters on the Altivar Process Drive do I need to configure to establish a connection and communicate to the drive over the Embedded Modbus Ethernet protocol?

        Issue:
        How do I setup the Altivar Process Drive to communicate over Modbus over Ethernet (TCP)?

        Product Line:
        Altivar Process Drive (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)

        Environment:
        All serial numbers 

        Cause:
        Need to connect to the drive and communicate over Modbus

        Resolution:

        Setting up Modbus TCP on the Drive
        EDS Files
        Basic Settings
        • Program Communication Settings:
          • [Communication] [Comm parameters] [Ethernet Embd] Config submenu
            • [IP Mode Ether. Embd]
            • [IP address]
            • [Mask]
            • [Gateway]
          • ​​​Setting up a Modbus Address
            • [Communication] [Comm parameters] [Modbus SL] [Modbus Fieldbus]
              • ​[Modbus Address]
              • [Bd.RateModbus]
              • [Modbus Format]
              • [Modbus Timeout]​​​
            • To read/write directly to individual 4x registers you will need to set a Modbus Address in the drive. 
              • The Modbus Address should match your Unit ID on PLC (Typically that is Unit ID of 1)
            • When using the IO scanner input/output tables you will need to use a Unit ID of 255
        • Remember to Power Cycle the Drive after any communication changes
        • Programming Command Settings:
          • [Complete settings] [Command and Reference]
            • ​For command speed from Network, program:
              • [Ref Freq 1 Config] Fr1 - Set to [Embedded Ethernet] Eth
              • [Ref 1B switching] rCb - Set to [Ref Freq Channel 1] Fr1
              • [Control Mode] CHCF - Set to [Not separ.] SIM
            • ​​Video: Setting an Auto/Manual or Reference Switching on the Altivar Process Drives
              • https://www.schneider-electric.com/en/faqs/FA294131/
        • Program Communication Settings (from SoMove)
          • ​​[Parameters List] [Fieldbus] [Modbus TCP/Ethernt IP]
          • Configure Drive Protocol (ATV900)
            • Ethernet Protocol - Set to Modbus TCP
        Commanding the Drive
        • Using IO Profile characteristics:
          • [Complete Settings] [Command and Reference] [Control Mode] - Set to "IO"
          • Command Word - 8501
          • 16 bit word (Bit 0, 1, 2..... 15)
          • Start/Stop must turn on bit 0 (first bit)
            • Write a 1 to start
            • Write a 0 to stop
          • Bit 1 to 15 are assignable to other drive functions like Fault Reset
          • Speed Reference
          • Speed Reference Word:
            • 8502 (Hz) and 8602 (rpm)
        • Using CIA402 (DriveCom Profile) characteristics:
          • Works with all assemblies
          • [Control Mode] to [Not separ.] or [Separate]
          • Command Word - 8501
          • No 16 bit word
          • Start/Stop
            • Drive will display nSt on top left corner.
            • A sequence of values must be written to the drive:
              • 6, 7 and 15 decimal values
              • Toggle between 7 and 15 to start and stop
          • Speed Reference
            • Speed Reference Word:
              • 8502 (Hz) and 8602 (rpm)

        Related FAQ: 
        FA316343: How do I troubleshoot an Altivar Process Drive that would not connect to a Modbus over Ethernet (Modbus TCP) network?


         

        Video: How is the automatic restart function enabled on Altivar Process drives?

        Issue:
        Enabling automatic restart function on the Altivar Process drives

        Product Line:
        Altivar Process Drive (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)

        Environment:
        All Products of Altivar Process Drive 

        Cause:
        Automatic restart after fault.

        Resolution:
        Automatic restart will only work if the drive is being controlled from the terminal strip in 2 wire control (will not work in HMI mode or while using Serial Communication) IF the fault is resettable AND the run command is maintained.

        Go into Complete Settings, Command and reference, and set 2 wire type to level control.
        Go into Complete Settings, Error/Warning Handling, Auto fault reset, and set auto fault reset to yes.
        The drive will attempt to reset the fault for the length of time programmed in the Fault Reset Time parameter (default is 5 minutes) as long as the run command remains present on the drive.

        It is also advisable to enable to Catch on the Fly in case the motor is already spinning when the drive restarts. (Complete Settings -> Error/Warning Handling)


        Conditions that have to be met:
        Must be in 2 wire control with run command present.
        The automatic restart function has to be enabled.
        The condition that caused fault code has to have been resolved.  

        The lists of fault codes that can be cleared automatically are listed in the ATV600 Programming Manual and ATV900 Programming Manual.


         

        Where can I download SoMove software and the drive/soft starter DTM files?

        Issue:
        Where can I download SoMove software?

        Product Line:
        SoMove Software

        Environment:
        All

        Cause:
        Needs SoMove software and DTM files

        Resolution:

        Below are the Links for SoMove Software and DTMs for AC Drives and Softstarts.

        DTM files will need to be installed for drive profile recognition prior to connection through Somove.
         
        SoMove core software:
        https://www.schneider-electric.us/en/download/document/SoMove_FDT/

        DTM file for Altivar 600 series process drives                             
        https://www.schneider-electric.com/en/download/document/ATV6xx_DTM_Library_EN/

        DTM file for Altivar 900 series process drives 
        https://www.schneider-electric.com/en/download/document/ATV9xx_DTM_Library_EN/

        DTM file for all other supported Altivar series drives (includes ATV12, ATV31, ATV312, ATV32, ATV61, ATV71, ATV212)   
        https://www.schneider-electric.com/ww/en/download/document/Altivar_DTM_Library

        DTM file for Altistart 22 and Altistart 48 soft starters  
        https://www.schneider-electric.com/en/download/document/Altistart_DTM_Library/

        DTM file for Altivar 320:
        https://www.schneider-electric.com/en/download/document/ATV320_DTM_Library/

        DTM file for Altivar 340:
        https://www.schneider-electric.com/en/download/document/ATV340_DTM_LibraryEN/

        WinZip or 7-Zip Extraction software may be needed for compressed/zipped files. If needed you can Download Free version 7-Zip from;  https://www.7-zip.org/

        Please let the software and DTM's install in their default file locations (just click "Next" and "Install"). 
         

        Show More