622T2

Switch Grid Plate and Cover, 2 Gang, Telemecanique

Catalogue Number: 622T2
622T2
Colour: White
Colour: Per UOM Std.
  • White 1 PCE
Added to cart

Specifications

hide show
Range of product
PDL 600 Designer Series
Product brand
Clipsal
Number of gangs
2 gangs
Product destination
switch
Material
metal

Frequently Asked Questions

hide show

What is the PDL plate to fit Push buttons ?

622T1, fits one push button
622T2, fits two push buttons
recommended to use with Harmony Style 5 range

Do we do a 622T1 with a smaller diameter hole

No, only version available to fit 22mm

Is there a LED version of the PDL 610MN

No but you could use a harmony indicator in a 622T1

What is a keyed selector switch to fit PDL 600 Series plate, key needs to be removed on / off position

Use PDL 622T + ZB5 key selector switch

Can you use the 624TM to run halogen and incandescent lighting

Yes 624TM can be used for both halogen and incandescent lighting

What is the alternate for 623TM, PDL trailing edge dimmer mechanism?

PDL 624TM is the alternate for 623TM trailing edge dimmer. PDL 624TM is rated to 450VA.
 

Key Features

  • Trailing edge control suitable for controlling incandescent globes, 240 V halogen lighting, and ELV lighting supplied by electronic transformers
  • 0 to 40 deg C
  • Mounting center: 84 mm
  • 1 or 2-way operation
  • Soft start operation
  • User adjustable minimum brightness
  • Ability to multi-gang in 600 series plates
  • Over temperature compensation
For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0000844.pdf

 

If a PDL 624TM dimmer is damaged due to a surge caused by a light bulb blowing is this covered under warrantee

No the warranty covers manufacturing faults not surges

What is the min/max load on PDL 624TM?

Maximum Load: 450W, 1.8A resistive. Minimum Load: 20W, 0.1A resistive
https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=1924

Video: Can the maximum peak current values be reset on the 6.0A trip unit?

Yes. Scroll to the max value screen and hold the scroll button for three seconds.

 

Do the HV circuit breakers and contactors work at 60 Hz ?

The HV circuit breakers and contactors work as well as 50 Hz and 60 Hz.
IEC 62271 is applicable to a.c. circuit-breakers designed for indoor or outdoor installation and
for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V.

 

What will cause an '-2222 - Internal error in file tiaifunc.cpp' error in Concept?

Error -2222 in Concept is caused by a corrupted DFB. Usually an ST section did not compile properly.
Export the project 'with used DFBs' and re-import.

Address Format for a BACnet Device in Scada

Issue
In I/O Devices form, what should the 'Address' field be set to?

Product Line
PowerScada Expert 8.1

Environment
I/O Devices form in the project.

Cause
A device communicating with BACnet protocol is being added to Scada.

Resolution
NOTES:
- The default UDP port is 47808.
- The 'device ID' uniquely identifies each BACnet device and can be in the range of 0 to 4194302.  In the examples below, it is assumed the device ID is 12262.

The address format for the configuration takes one of the following two structures:

1. If the default UDP port is used:
    <device ID> -I <device IP Address>
    12262 -I 10.167.167.25

2. If non-standard UDP port is configured in the device (assume UDP port of 48000):
    <device ID> -I <device IP address> -U < device UDP port number>
    12262 -I 10.167.167.25 -U 48000



 
Show More