keytag 5 star 55mm

Keytag 5 Star 55mm

Catalogue Number: 6200KT
keytag 5 star 55mm
Retail
$174.24
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
key tag
Width
56 mm
Thickness
0.7-1.2 mm
Package 1 Weight
116 g
Package 1 Height
45 mm
Package 1 width
88 mm
Package 1 Length
129 mm

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • End of Life Manual

Frequently Asked Questions

hide show

Is part number FLR30LED available below 6000k?

No. Unfortunately, the part is not available below 6000k.

What voltage is the key tag 6200KT and does it come with a Card?

It is 24V DC

Enquire at Assa Abloy 1300 562 587.

Unfortunately we do not sell the cards.

What is the dimension of FLR50LED, 50W, 6000K, IP65 floodlight?

Dimensions of FLR50LED are as follows:
Width - 270 mm
Height -206 mm
Depth - 40.1 mm
Weight - 1.7 kg
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=FLR50LED

What is the load rating of the INS62043?

200KG listed in the floor box catalog.

What are the placement considerations for the condenser relative to the InRow ACRD10x?

Issue:
What are the placement considerations for the condenser relative to the InRow ACRD10x?

Product line:
ACRD100, ACRD101

Environment:
Data Center Cooling

Cause:

Resolution:
The condenser should always be placed above the InRow ACRD10x unit at a distance not to exceed 200ft equivalent pipe length.

 

6200: Reading energy values off the front panel display.

Issue
How to read energy values off the front panel display of ION 6200 meter.
 
Product Line
ION 6200
 
Environment
ION 6200 front display reading energy values
 
Cause
Energy values are often directly read off the front panel display. However, the 6200 Installation and Operation Guide do not explicitly describe how to get these energy values.
 
Resolution
The KWh front panel display constitutes of three rows. Say that the first row of the KWh display is showing 'aaa', the second row shows 'bbb' and the third row shows 'ccc', then the total KWh read by the meter is aaa bbb ccc KWh.

The 6200 is hard-coded to roll over at 100 000 000 KWh. As the KWh starts accumulating, the third row on the display shows an increment in value. When the value goes over 999 KWh, the second row is used to display the KWh values up to 999 999 KWh. Eventually, when the value goes over 999 999 KWh, the top row is also used to display the KWh until the KWh rolls over at 100 000 000 KWh.
 
Example: As shown in picture below (from ION 6200 front display), the total kwh accumulated is = 270,050 kwh
 

 

What are the placement considerations for the fluid cooler relative to the InRow ACRD20x?

Issue:
What are the placement considerations for the fluid cooler relative to the InRow ACRD20x?

Product line:
ACRD200, ACRD201

Environment:
Data Center Cooling

Cause:

Resolution:
The fluid cooler can be placed up to 600ft equivalent pipe length from the unit. The fluid cooler may be placed at levels above or below the unit within the distance specified. The longer the distance of the fluid cooler from the indoor unit, the larger the size of the pump required. 
 

Air flow for ATV78 from 200kw up to 710kw

Goals and Symptoms

For our costumer in the M30 project that are going to buy some ATV78, they are asking me about the flow of the fans necessary for the enclousure, in the catalog page 38 it apeears up to 160kw, and I need for the powers from 200 to 710kw high torque

Causes and Fixes

From ATV 780C20Y to ATV 780C31Y -> air cooling: 2600m3/h
From ATV 780C35Y to ATV 780C50Y -> air cooling: 3900m3/h
From ATV 780C56Y to ATV 780C71Y -> air cooling: 5200m3/h


Legacy KB System (APS) Data: RESL180523 V1.0, Originally authored by on , Last Edited by YoBl on 01/16/2007
Related ranges: Altivar 78

Where can I download the installation and operation guide for an ION 6200 meter?

Issue
A user needs to download the installation and operation guide for the ION 6200 meter.
 
Product Line
ION6200

Cause
A user needs to download the installation and operation guide for the ION 6200 meter.
 
Resolution
See the attached documents below.

What is the Voltage Insulation for the Optical Isolation on the RS-485 port?

The withstand insulation test voltage for optical isolation for the meters are:

6200: 4330 Vrms
73xx: 4330 Vrms
75xx/76xx: 3750 Vrms
7700: 2500 Vrms
8500/8400/8300: 5303 Vrms
8600: 3750 Vrms
8800: 3750 Vrms




Last Revised: September 21, 2007
Internal PMO/PMC
All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL188303 V1.0, Originally authored by KBAdPM on 10/04/2007, Last Edited by KBAdPM on 10/04/2007
Related ranges: ION8800, ION8600, ION7550/ION7650, ION7300, ION6200, ION8500, ION8400, ION8300, ION7700, ION7500/ION7600

ION 6200 Sample Rate Information

Issue

Information on the sampling rate of the ION6200

Product Line

ION6200 meters

Environment

All released meter firmware

Discussion

The sampling rate of the ION 6200 is 64 samples/cycle. With this sampling rate, the meter should be able to calculate harmonics up the 31st harmonic.
However, for the THD calculation, only the first harmonics are taken into account; this has been verified with firmware.

In addition, the ION 6200 is a blind cycle meter which means that...since the meter takes 64 samples per cycle, it actually uses all 64 samples to calculate the data.
These samples are locked to the frequency of V1.

 

Adding ION Devices to ION Enterprise through an EGX Gateway

See attached ION Knowledge Base article.
Adding devices through EGX Gateway.pdf


Please Read:

The above article details the procedure for adding ION devices to an ION Enterprise system through an EGX100 gateway. This process is necessary due to protocol conflicts. The EXG100 speaks Modbus protocol, where ION Enterprise expects ION meters to speak ION protocol when connecting to them. The exception to this is the ION 6200, which has a native Modbus driver to allow it to speak Modbus protocol to ION Enterprise.


Legacy KB System (APS) Data: RESL182364 V2.0, Originally authored by DaMi on 02/27/2007, Last Edited by MaTh on 10/12/2012
Related ranges: ION Enterprise V5.5
Show More