Image of 611M 600 Series RJ45 Mounting Adaptor Module

RJ45 Jacks and WAll Plates, Mounting Adapter Clip, for 600 Series

Catalogue Number: 611M
Image of 611M 600 Series RJ45 Mounting Adaptor Module
Colour: White
Colour: Per UOM Std.
  • Black 1 PCE
  • White 1 PCE

Specifications

hide show
Range of product
  • Series 600
  • PDL
    • Product brand
      Clipsal
      Product or component type
      clip
      Localisation on device
      adaptor frame

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Is there a Lexcom RJ45 connector that fits in a PDL plate

      Yes, use a VDI552012 + 611M

      What is the dimensions for the PDL 611M mounting adaptor clip

       They only fit the 600 series plates

      What is the physical length of a XS608B1PAM12

       The length is 61mm

      Is the PDL 618M a replacement for the old PDL telephone mech - also is it a Master or Slave

      The PDL 618M is a Slave.  If the master needs replacing, system will need to be converted to a 2wire system.

      What is the part number for a PDL single gang grid and cover?

      The part number for a PDL single gang grid and cover is a 681VH.
      Some of the key features are:
      • Standard
      • also suitable for a 681M metal cover plate
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=681VH​

      Is it allowed to extend the lead on a BCPM split core CT?

      Issue:
      Is it allowed to extend the lead on a BCPM split core CT?
      If so, What is the maximum recommended length of the lead extension?

      Product Line:
      BCPM split core CT

      Environment:
      Extending CT Leads for BCPM split core CT

      Cause:
      Customer is requesting to extend the CT length with minimal to no accuracy changes.

      Resolution: 

      Yes, you may extend the CT leads.

      6.1m (20ft) is the our recommended maximum length for CT extension leads.
      One of our recommended accessories, the BCPMSCCT0R20, is such a 6.1m lead, referred to on page xxiii of the PowerLogic¿ BCPMSC
      Branch Circuit Power Meter with Split-Core CTs Panelboard Monitoring System Installation Guide, available here:
      https://www.powerlogic.com/literature/BCPMSC_Z205658-0C.pdf
      See also RESL191029 which discusses wire size and attenuation.

      Getting error E6111 on LXM32 drive

      Issue:
      Getting error E6111 on LXM32 drive

      Product Line:
      LXM32

      Resolution:
      Error 6111 appears when you try to perform a second movement (commands from the field bus) at the same time that auto-tuning is being performed.
      To avoid this, you must deactivate access from the bus (stopping the master for example) during the auto-tuning operation.

      Network Management Card 2 Firmware v6.X.X FAQ/Upgrade Issues


      Issue

      This knowledge base is intended to summarize and provide information on any FAQ or Upgrade Issues that have been identified with Network Management Card 2 (NMC2) v6.X.X firmware.


      Please note: This article also includes information about an important Information Bulletin. (INFORMATION BULLETIN - Network Management Card 2 upgrade from v5.1.X to v6.0.6 incorrectly maps SMTP server informationknowledge base FA175981.)



      Product Line
       
       
      • Network Management Card 2 - AP9630/30CH, AP9631/31CH, AP9635/35CH
        
      Devices with an embedded Network Management Card 2 include (but are not limited to): 2G Metered/Switched Rack PDUs (AP84XX, AP86XX, AP88XX, AP89XX), Certain Audio/Video Network Management Enabled products.

       
       
      Environment
       
      • All serial numbers
      • All users upgrading from v5.X.X firmware to v6.X.X
      • Users new to v6.X.X firmware
       
      Cause

      This information is provided a supplement to assist users in understanding any FAQ or other recommended references available for NMC2 v6.X.X firmware.



      Resolution


      Refer to the information and links below for further information.
       
       
       
       
       
      • Knowledge base FA167693 - Things To Consider When Upgrading or Downgrading a Network Management Card 2 (NMC2) Device between v5.X.X and v6.X.X

      •  Knowledge base FA175981 - INFORMATION BULLETIN: Network Management Card 2 upgrade from v5.1.X to v6.0.6 incorrectly maps SMTP server information  

      • Knowledge base FA175980 - v6.X.X Network Management Card 2 "Reset All" or "Reset to Defaults" Command Does Not Work  

      • Knowledge base FA176048 -  Network Management Card 2 config.ini upload for event notification settings does not enable events in v6.X.X

      • Knowledge base FA175982 - v6.X.X Network Management Card 2 config.ini DefaultUserTemeratureScale (misspelled) keyword value displays the opposite of the actual setting

      • Knowledge base FA170552 - Network Management Card 2 (NMC2) v6.X.X User Types and Permissions Definitions
      • Knowledge base FA176542Mass Configuration of Users and User Preferences on Network Management Card 2 (NMC2) v6.X.X
      • Knowledge base FA177701 - Network Management Card 2 (NMC2) v6.X.X potential reboot loop or TCP/IP stack failure experienced when SMTP server MX record is not cached on user's DNS server
      • Knowledge base FA177263 - Symmetra LX Battery Module Information Missing within v6.X.X Network Management Card Firmware Web Interface
      • Knowledge base FA231396 - UPS Network Management Card 2 Firmware Application Compatibility for Smart-UPS Online (SRT) Models
      • Knowledge base FA233873 - About->Support menu option missing from AP8XXX series Rack PDU Web Interface on certain firmware versions
      • Knowledge base FA234740 - "Battery Predicted Replacement Date" missing from AP9630/31 UPS Network Management Card 2 (NMC2) Web Interface on supported UPS models
      • Knowledge base FA235265 - HTTP/HTTPS Web Access does not work in v6.X.X firmware but works on v5.X.X in certain NMC2 configurations/environments   

      • Knowledge base FA235654Network Management Card 2 (NMC2) does not parse .csf files uploaded via Secure Copy (SCP)  

      • Knowledge base FA235716UPS Network Management Card 2 (NMC2) Certain Events do not work properly with the Dry Contact I/O Accessory (AP9810) Control Policy

      • Knowledge base FA238090Using UPS Network Management Card 2 (NMC2) v6.2.0 sumx application to upgrade SMT UPS firmware via Internet Explorer may fail

      • Knowledge base FA241052 - After upgrading firmware on my APC AP8XXX series Rack PDU, the input voltage reads 1V

      • Knowledge base FA242818Chinese language does not work properly with sumx & sy UPS Network Management Card 2 (NMC2) applications v6.2.1

      • Knowledge base FA238115Unable to access my APC Network Management Card (NMC) enabled device via HTTPS (SSL/TLS)

      • Knowledge base FA243736"Ignore PCNS shutdown commands" missing from UPS Network Management Card 2 (NMC2) PowerChute Shutdown Parameters options


       
      Knowledge Base Article ID Resolved Network Management Card AOS or APP Module Version Required
      FA175981, FA176048 AOS v6.1.1 or higher
      FA175980 AOS v6.1.3 or higher
      FA175982 AOS v6.1.6 or higher
      FA170552 (and related to note in FA176542) AOS v6.1.3 or higher
      FA177701 AOS v6.1.3 or higher
      FA177263 sy APP v6.2.0 or higher
      FA231396 sumx APP v6.2.0 or higher
      FA233873 rpdu2g APP v6.3.3 or higher
      FA234740 sumx v6.3.3 or higher
      FA235265 AOS v6.3.3 or higher
      FA235654 AOS v6.3.3 or higher
      FA235716 undetermined future version of sumx firmware APP
      FA238090 under investigation for future version of sumx firmware APP
      FA241052 v6.3.2 rpdu2g firmware APP
      FA242818 language pack fix attached in knowledge base ID
      FA238115 detailed fix information available in knowledge base ID
      FA243736 undetermined version of sumx/sy APP, workaround available in knowledge base ID



      Note: Each Network Management Card has an AOS and application file (APP) and they cannot be updated independently. Please check https://www.apc.com/tools/download/index.cfm to verify the latest versions available for your device. Please also consider any suggested workarounds if a firmware upgrade is not yet available.