Quantcast

32A Socket Range

White | 32A Socket Range

32A Socket Range

Item Number: 576-WH

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

PDL 500 Standard Series

Product brand

Clipsal

Physical

Marking

without marking

Local signalling

without light indicator

Others

Cover type

full cover plate

Package 1 Weight

1 kg
Show all specifications

Frequently Asked Questions

hide show

How do I wire the TSXDSY08T31 48 VDC protected transistor output module for a Premium PLC?

TSXDSY08T31 wiring the 48 VDC protected transistor output module as per the diagram:

What is the part number for a 40A single pole 50kA Circuit Breaker?

The part number is LV438576.
 

Why can't I connect to my APC Network Management Card or embedded Network Management Card using a serial connection?


Issue

Unable to connect to a Network Management Card or Network Management Card enabled device via a serial connection.


Product Line


Web/SNMP Card - AP9606
Devices with an embedded Web/SNMP Card include (but are not limited to): Environmental Monitoring Unit 1 (AP9312TH)

Network Management Card 1 (NMC1) - AP9617, AP9618, AP9619
Devices with an embedded Network Management Card 1 include (but are not limited to): Metered/Switched Rack PDUs (AP78XX, AP79XX), Rack Automatic Transfer Switches (AP77XX, Environmental Monitoring Units (AP9320, AP9340, Netbotz 200)

 
Network Management Card 2 (NMC2) - AP9630/AP9631CH, AP9631/AP9631CH, AP9635/AP9635CH
Devices with an embedded Network Management Card 2 include (but are not limited to): 2G Metered/Switched Rack PDUs (AP84XX, AP86XX, AP88XX, AP89XX), Rack Automatic Transfer Switches (AP44XX), Certain Audio/Video Network Management Enabled products, Smart-UPS Online (SRT).

Environment

• All firmware versions
• All serial numbers


Cause

Several issues can cause a problem with a terminal session over a serial connection. See below for some troubleshooting tips.


Resolution
  1. Check the physicals – Ensure you are using the correct cable. There are several different communication cables APC manufactures. Check your unit’s user manual for the correct part number, which should also be printed on the cable itself. If you have another cable, try it. You can also confirm the cable works if you have another unit to try it in.
  1. Ensure you are using the correct COM port - Some servers have many com ports. Ensure you are using the communication port mapped to the serial port.
  1. Ensure you are connecting at the correct settings - APC units can communicate at 2400, 9600, 19200, 38400, and 57600 bps. Please reference the product’s user manual for the default settings. You can also try connecting at each rate. Please keep in mind that the baud rate CAN BE CHANGED by the user, a change to the configuration file, or a managing device like ISX Manager or StruxureWare Central.

    APC units can be forced to a baud rate at the username and password prompt. If you are having an issue connecting, try setting the baud rate to a different value:

    Username: <username>
    Password: <password><space>-<baud rate>

    This example will set the baud rate to 2400 bps, using the default username and password:

    Username: apc
    Password: apc -2400

    The unit will inform you of the baud rate change. If it does NOT, you might have the incorrect username and password. In which case, reference knowledgebase number FA156075.
     
  2. If applicable, check to ensure your USB to Serial Adapter is working properly - Many of these devices require a driver to work properly. Check to make sure this device is recognized correctly by your operating system.

What is an alternative for PM1200?

What is the neutral CT catalog number for a P frame Powerpact breaker?

Product Line:
Circuit Breakers
PowerPact P

Environment:
Electrical Distribution Equipment

Resolution:
Neutral CT`s are as follows:
S33575 250A
S33576 400 to 1600A


 

What are the neutral current transformers used for ground fault sensing NT and NW Masterpact breakers?

Product Line:
NT and NW Masterpact breaker

Resolution:
 
 Table 41:        T-Frame Circuit Breakers
External neutral sensor for 3-phase, 4-wire residual ground fault system (or for neutral current monitoring).
These neutral sensors include their wiring harness. To order this harness as a spare part, order cat. no. NCTWIRING. 
 
NT Circuit Breaker
Sensor Plug
 External Neutral Sensor for general useExternal Neutral Sensor
Square D Panelboard
External Neutral Sensor for use in
Square D Switchboards
  External neutral sensor for circuit breakers with standard neutral protection
100–250 AS33575S33924S33926
400–1600 AS33576S33925S33927
  External neutral sensor for circuit breakers with oversized neutral protection♦
100 AS33575S33924S33926
250 AN/AN/AN/A
400–1000 AS33576S33925S33927
1200/1250 AS48896N/ANA
1600 AS48182N/ANA
♦Oversized neutral protection = 1.6xIr where Ir = long time pick-up.


Table 42:        W/Y-Frame Circuit Breakers
External neutral sensor for 3-phase, 4-wire residual ground fault system (or for neutral current monitoring) and external sensor for Modified Differential Ground Fault (MDGF) or Source Ground Return (SGR) system.
These neutral sensors include their wiring harness. To order this harness as a spare part, order cat. no. NCTWIRING.
 
 

Frame
Size
 

Sensor Plug (A)
External Neutral SensorPZ4 External Neutral Sensor
(For use in PZ4 Switchgear)

 
MDGF/ SGR
Sensor►
 
For Residual Ground Fault
For 3-Pole Circuit Breaker with
Oversize Neutral
Protection♦
 
For Residual Ground Fault
For 3-Pole Circuit Breaker with
Oversize Neutral
Protection♦
 





W
100 S48916S48916 S48902S48902 
250N/AN/A
400 


S34036
 
S34036
 


S48903
 

S48903
 



S33579
600/630
800
1000
1200/1250S48896
1600 
S48182
 


N/A
2000S48896
2500 

S48182
 

S48182
3000 
N/A
3200
4000N/A
 



Y
2000 



S48897•
 

S48897•
 

S48898•
 
S48898•
 



S33579
2500
3000 


N/A
3200
4000
5000 
N/A
 S48897•
6000
6300N/A
•Kit includes qty. (2) neutral sensors.
►Four MDGF sensors (phase + 1 neutral) are required for W-frame; eight MDGF sensors are required for Y-frame. For SGR system, only one sensor (neutral) is required for W-frame; two sensors for Y-Frame.
        An MDGF/SGR ground fault interface module (Cat. no. S48891) is also required for each circuit breaker. 
♦Oversized neutral protection = 1.6xIr where Ir = long time pick-up.

See catalog 0613DB1607 for more Masterpact parts
Show More