570S

Surface Socket Square 500 Series

Catalogue Number: 570S
570S
Colour: White
Colour: Per UOM Std.
  • White 1 PCE
Added to cart

Specifications

hide show
Range of product
PDL
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
Device mounting
surface

Frequently Asked Questions

hide show

is there a mounting clip for the 570S?

No the 570S is supplied with a panel clamp for fitting through rectangular entry.
38mm wide x 31mm high.

What is the part code for a 15A version of 570S

There is no 15A version of 570S, only in the 193 range which are round not square ie 193/15/1

Is there a mounting block for the PDL570S?

No there is not. This is designed to panel mount directly onto surfaces.

For a wall mounted alternative you can use the round PDL570R with a PDL530 mounting block.

PDL570S - what colours does it come in?

WH white and BK black.

Video: How to setup basic connection to SCADAPack 570/575

Video:

How to setup basic connection to SCADAPack 570/575

Product Line

SCADAPack 570, SCADAPack 575

Environment

Remote Connect

Description

This video will provide a brief demonstration of getting basic communications with SCADAPack 570/575 RTU.

NetBotz | Do NetBotz support BACnet Integration?

Issue
Do NetBotz appliances support BACNET Integration?

Product Line
NetBotz 700 Series
- NetBotz Rack Monitor 750 (NBRK0750)
NetBotz 300-500 Series (v3)
- Wall Appliance: 355/356 (NBWL0355/6) & 455/456 (NBWL0455/6)
- Rack Appliance: 450/451 (NBRK0450/1), 550 (NBRK0550), & 570 (NBRK0570)
NetBotz 200 Series
- NetBotz Rack Monitor 250
- NetBotz Rack Monitor 200

Environment
NetBotz 200, 300-500, & 700 Series (all versions)
BMS (BACnet Integration)

Resolution

BACnet Integration is not currently supported by any Netbotz devices / appliances. NetBotz v3 (355, 450, 455, 550, & 570) & NetBotz 250 appliances do offer a Modbus output option.

NetBotz Rack Access POD 170/171 | Manual and Installation Guides

Issue:
   Where can I find the manual for the APC Rack Access Pod 171 NBPD0171?

Product Line:
  Netbotz Appliance (455, 550, 570, & 750)

Environment:
   Netbotz Rack Access NBPD0171
   NetBotz Rack Access NBPD0172

Resolution:

NetBotz Rack Access Pod 170 (for APC SX rack)
https://www.apc.com/shop/us/en/products/NetBotz-Rack-Access-Pod-170-for-APC-SX-rack-/P-NBPD0171

NetBotz Rack Access Pod 170 (for Chatsworth GlobalFrame rack)
https://www.apc.com/shop/us/en/products/NetBotz-Rack-Access-Pod-170-for-Chatsworth-GlobalFrame-rack-/P-NBPD0172
 

NetBotz | What is compatible?

Issue:
What is compatible with a NetBotz Appliance?

Product Line:
NetBotz Appliance (250, 355, 450, 455, 570, & 750)

Environment:
NetBotz (all versions)

Cause:
This article explains in detail the entire NetBotz product line compatibility for Universal Sensors, Cameras, Rack Access, and Software.

Resolution:

NetBotz Appliance Compatibility Matrix
https://www.apc.com/salestools/JHIN-7PTK7P/JHIN-7PTK7P_R8_EN.pdf?sdirect=true

NetBotz Appliance Specifications Chart
https://www.apc.com/salestools/JHIN-7PTKDA/JHIN-7PTKDA_R4_EN.pdf?sdirect=true

NetBotz 250 Brochure
https://www.apc.com/salestools/MKEY-ADCS74/MKEY-ADCS74_R1_EN.pdf

NetBotz 750 Brochure
https://www.apc.com/salestools/SBRN-B7CKMD/SBRN-B7CKMD_R0_EN.pdf​

Can StruxureWare Data Center Expert be configured to alert for NetBotz 3xx, 4xx, and 5xx devices?

Issue:

Can StruxureWare Data Center Expert be configured to alert for NetBotz 3xx, 4xx, and 5xx devices?

Product Line:

StruxureWare Data Center Expert
NetBotz

Environment:

StruxureWare Data Center Expert monitoring NetBotz using HTTP or HTTPS

Cause:

StruxureWare does not alert for NetBotz 3xx, 4xx, or 5xx devices that are being monitored using http or https (please note there is no DCE option to monitor these devices using SNMP.)

Resolution:

Ever since their integration with NetBotz Central, NetBotz devices were designed to alert for themselves. This was done to eliminate NetBotz Central as a single point of failure. This functionality is retained by DCE.

Although you can configure the NetBotz appliance through DCE, the alerting for sensors, their thresholds, and their communications status is handled by the NetBotz appliance directly. The only alert StruxureWare DCE will alert for is if DCE itself loses communications with the NetBotz device (and only if the DCE server has a user with an associated e-mail that also has access to that NetBots appliance.)  This does not necessarily mean that the NetBotz is off-line or even that it is not capable of alerting for itself, this simply means that DCE can not communicate and it could be because of anything from user/password changes to the device itself actually being off-line.

Please note that this is different than the NetBotz Rack Access AP9361, NetBotz 200, or NetBotz 250 which are monitored using SNMP. Devices monitored in this manner can be configured to alert for themselves but they are normally configured to alert through DCE for convenience.
 

NetBotz 300-500 Series | Password reset procedure

Issue:
How do I reset the password on a 300-500 series NetBotz appliance.

Product Line:
NetBotz 300-500 Series (355, 455, 450, 550, & 570)

Environment:
NetBotz 300-500 Series (all versions)

Cause:
Recover from lost client/web password or root password.

Resolution:

Recovering a Lost Web/Advanced View/Root Password
                                  

1) Locate the reset switch on the appliance.  On a wall mount version (355/455) the reset button is on the bottom next to the USB-B port.  On a Rack Mount appliance (450/550/570) the reset button is next to the Input Power connection.

2) Using a thin wire such as a paperclip, press and hold down the reset switch for ten seconds. This
will cause the system to reboot.

3. Once the system reboots, you have two minutes to log in using the following default login values:
     a. For Advanced View
          • User ID: apc
          • Password: apc
     b. For the console
          • User ID: root
          • Password: apc

4. Once you have logged in to Advanced View, change the root password and apc account password to ensure security.
Note: If you do not log in within two minutes after holding down the reset switch, you must repeat the procedure.

Note: On older Version 2 NetBotz 320, 420, and 500 appliances, the password alone can not be reset. The entire device must be reset using the "configreset" option as detailed in k-base FA158175.


 

NetBotz | End of Sale & End of Support Information

Issue:
   NetBotz - End of Sale & End of Support Information

Product Line:
   NetBotz (all models)
   NetBotz Central

Environment:
   NetBotz (all versions)

Resolution:

NetBotz End of Sale & End of Support
 
SKU Description End of Sale End of Support Recommended Replacement
AP9319 Environmental Monitoring Unit July 2006 July 2008 NBRK0250
AP9320 Environmental Management System September 2015 September 2017 NBRK0250
AP9340 Environmental Manager January 2017 January 2019 NBRK0250
NBRK0200 / NBRK0201 NetBotz Rack Monitor 200 October 2016 October 2018 NBRK0250
AP9360 Proximity Card Rack Lock Kit August 2007 August 2009 NBACS125
NBACS1356
AP9361 Rack Access PX - HID October 2016 October 2018 NBACS125
​NBACS1356
NBWL0300* WallBotz 300 / 300B January 2003 January 2005 NBWL0355A
NBRK0303 RackBotz 303 January 2003 January 2005 NBRK0750
NBWL0310
NBWL0310C
WallBotz 310 / 310C July 2005 June 2008 NBWL0355A
NBRK0310
NBRK0310C
RackBotz 310 / 310C July 2005 June 2008 NBRK0750
NBWL0400
NBWL0400C
WallBotz 400 / 400C July 2005 June 2008 NBWL0455A
NBRK0400
NBRK0400C
RackBotz 400 / 400C July 2005 June 2008 NBRK0750
NetBotz 320 NetBotz 320 Rack Mount July 2009 July 2014 NBRK0750
NetBotz 320 Wall Mount July 2009 July 2014 NBWL0355A
NBWL0356A
NetBotz 320 Environmental July 2012 July 2017 NBRK0750
NetBotz 420 NetBotz 420 Rack Mount May 2009 May 2014 NBRK0750
NetBotz 420 Wall Mount May 2009 May 2014 NBWL0455A
NBWL0456A
NetBotz 420 Environmental May 2012 May 2017 NBRK0750
NetBotz 500 NetBotz 500 Wall Mount October 2013 October 2018 NBWL0455A
NBWL0456A
NetBotz 550
NetBotz 551
NetBotz Rack Monitor 550 / 551 June 2013 December 2018 NBRK0750 OR
NBRK0570
Firmware for the NetBotz 550/551 is still being released as it is the same firmware that is used with the 355/455/450/570.  Support can no longer be purchased on the NetBotz 550 due to the 5 year limitation of hardware/software support.
V2 Sensors* Sensors with PS/2 Connectors October 2017 October 2019 N/A*
NBPD0121 Camera Pod 120 November 2017 November 2019 N/A*
NBPD0122 Sensor Pod 120 October 2017 October 2019 N/A*
NBPD0180 Sensor Pod 180 April 2019 TBD N/A
NBCN1000 NetBotz Central September 2004 September 2006 StruxureWare Data Center Expert
*V2 Sensors (PS/2 connection) are only supported when they are integrated into a supported version 3 appliance (models: 355, 455, 450, & 570) utilizing a sensor POD 120.

Information on current appliances and compatibility/specifications can be found in knowledge base FA256261.

NetBotz 300-500 Series | SNMP MIB File

Issue:
SNMP MIB for NetBotz Version 2 and 3 Appliances

Product Line:
NetBotz 300-500 Series Version 3
v3 Wall Appliance: 355/356 (NBWL0355/6) & 455/456 (NBWL0455/6)
v3 Rack Appliance: 450/451 (NBRK0450/1), 550 (NBRK0550), & 570 (NBRK0570)

Environment:
NetBotz v2/v3 (all versions)

Resolution:

The SNMP MIB for NetBotz Appliances can be downloaded from the NetBotz Appliance itself by accessing the following URL:

For version 3:
https://ip_address_of_appliance/netbotzv3.mib

For version 2:
https://ip_address_of_appliance/netbotzv2.mib

 